Literature DB >> 20408132

The inter- and intra-operator variability in manual spot segmentation and its effect on spot quantitation in two-dimensional electrophoresis analysis.

Renato Millioni1, Stefano Sbrignadello, Andrea Tura, Elisabetta Iori, Ellen Murphy, Paolo Tessari.   

Abstract

Separation of complex mixtures of proteins by 2-DE is a fundamental component of current proteomic technology. Quantitative analysis of the images generated by digitization of such gels is critical for identifying alterations in protein expression within a given biological system. Software packages are designed for this purpose. The accurate definition of protein spot boundaries, using a suitable method of image segmentation, is a key requirement for image analysis. It is often necessary for operators to intervene manually to correct mistakes in spot segmentation; therefore operator subjectivity and differences in ability can weaken the analysis. We estimated the error in spot quantification after manual spot segmentation, which was performed by different operators, using two different software packages. Our results clearly show that this operation was associated with significant inter- and intra-variability and an overestimation of subsequent spot intensity, especially when spots were weak. For comparative studies, we suggest separately analysing spots which have been manually segmented by imposing a requirement for at least a threefold difference in spot intensity in addition to use of statistical tests.

Mesh:

Year:  2010        PMID: 20408132     DOI: 10.1002/elps.200900674

Source DB:  PubMed          Journal:  Electrophoresis        ISSN: 0173-0835            Impact factor:   3.535


  4 in total

1.  A "loop" shape descriptor and its application to automated segmentation of airways from CT scans.

Authors:  Jiantao Pu; Chenwang Jin; Nan Yu; Yongqiang Qian; Xiaohua Wang; Xin Meng; Youmin Guo
Journal:  Med Phys       Date:  2015-06       Impact factor: 4.071

2.  A Sensitive Thresholding Method for Confocal Laser Scanning Microscope Image Stacks of Microbial Biofilms.

Authors:  Ting L Luo; Marisa C Eisenberg; Michael A L Hayashi; Carlos Gonzalez-Cabezas; Betsy Foxman; Carl F Marrs; Alexander H Rickard
Journal:  Sci Rep       Date:  2018-08-29       Impact factor: 4.379

3.  CT-Based Pelvic T1-Weighted MR Image Synthesis Using UNet, UNet++ and Cycle-Consistent Generative Adversarial Network (Cycle-GAN).

Authors:  Reza Kalantar; Christina Messiou; Jessica M Winfield; Alexandra Renn; Arash Latifoltojar; Kate Downey; Aslam Sohaib; Susan Lalondrelle; Dow-Mu Koh; Matthew D Blackledge
Journal:  Front Oncol       Date:  2021-07-30       Impact factor: 6.244

4.  Technical variability of 2D gel electrophoresis - Application to soybean allergens.

Authors:  Catherine Pallen; Claire Friry-Santini; Corinne Herouet-Guicheney; Annabelle Capt
Journal:  Toxicol Rep       Date:  2014-09-16
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.