Literature DB >> 20404734

Xenon ventilation imaging using dual-energy computed tomography in asthmatics: initial experience.

Eun Jin Chae1, Joon Beom Seo, Jeongjin Lee, Namkug Kim, Hyun Woo Goo, Hyun Joo Lee, Choong Wook Lee, Seung Won Ra, Yeon-Mok Oh, You Sook Cho.   

Abstract

PURPOSE: To assess the feasibility of xenon ventilation computed tomography (CT) for evaluating ventilation abnormality in asthmatics.
MATERIALS AND METHODS: Twenty-two, stable asthmatics (M:F = 10:12; mean age, 57.6) were included. Single-phase, whole-thorax, dual-energy CT was performed using dual-source CT (Somatom Definition, Siemens) after subjects had inhaled 30% xenon for 90 seconds. Parameters include 512 x 512 matrix; 14 x 1.2 mm collimation; 40/140 eff. mAs at 140/80 kV; 0.45 pitch; and 0.33 seconds rotation time. On the color-coded xenon map, the extent of the ventilation defect was visually assessed using a 5-point scale in each lobe (0, absent defect; 1, 0%-25%; 2, 25%-50%; 3, 50%-75%; and 4, 75%-100%), which was defined as defect score. On the weighted average image, airway wall dimensions were measured at 4 segmental bronchi in both upper and lower lobes. Patients were classified into a defect group and a defect-free group based on the presence of defects shown on the xenon map. Pulmonary function test parameters and airway wall dimensions were compared in those 2 groups. Correlation analyses between the defect score, pulmonary function test, and airway wall dimensions were performed.
RESULTS: Sixteen asthmatics showed peripheral ventilation defects on the xenon map (defect score, 6.6 +/- 4.2). The defect group had a significantly lower forced expiratory volume in 1 second (FEV1) and thicker airway wall than that of the defect-free group (P = 0.04 and 0.02, respectively). The defect score correlated negatively with a ratio of FEV1 and forced vital capacity (FEV1/FVC) (r = -0.44, P = 0.04) and corrected diffusing capacity (r = -0.76, P = 0.04) and correlated positively with total lung capacity, functional residual volume, and residual volume (r = 0.90, P = 0.005; r= 0.99, P < 0.001; r = 0.88, P = 0.008, respectively).
CONCLUSIONS: The ventilation defects appeared on xenon ventilation CT in asthmatics with more severe airflow limitation and airway wall thickening. The extent of the ventilation defects showed correlations with parameters of pulmonary function test.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20404734     DOI: 10.1097/RLI.0b013e3181dfdae0

Source DB:  PubMed          Journal:  Invest Radiol        ISSN: 0020-9996            Impact factor:   6.016


  27 in total

Review 1.  Lung imaging in asthmatic patients: the picture is clearer.

Authors:  Mario Castro; Sean B Fain; Eric A Hoffman; David S Gierada; Serpil C Erzurum; Sally Wenzel
Journal:  J Allergy Clin Immunol       Date:  2011-06-02       Impact factor: 10.793

2.  Quantitative analysis of dynamic airway changes after methacholine and salbutamol inhalation on xenon-enhanced chest CT.

Authors:  Sang Joon Park; Chang Hyun Lee; Jin Mo Goo; Jong Hyo Kim; Eun-Ah Park; Jae-Woo Jung; Heung-Woo Park; Sang-Heon Cho
Journal:  Eur Radiol       Date:  2012-06-27       Impact factor: 5.315

Review 3.  Imaging techniques for tumour delineation and heterogeneity quantification of lung cancer: overview of current possibilities.

Authors:  Wouter van Elmpt; Catharina M L Zegers; Marco Das; Dirk De Ruysscher
Journal:  J Thorac Dis       Date:  2014-04       Impact factor: 2.895

Review 4.  Emphysema and lung volume reduction: the role of radiology.

Authors:  Katharina Martini; Thomas Frauenfelder
Journal:  J Thorac Dis       Date:  2018-08       Impact factor: 2.895

Review 5.  Dual-energy lung perfusion and ventilation CT in children.

Authors:  Hyun Woo Goo
Journal:  Pediatr Radiol       Date:  2013-02-16

6.  Determination of infarct size in ex vivo swine hearts by multidetector computed tomography using gadolinium as contrast medium.

Authors:  Akos Varga-Szemes; Balazs Ruzsics; Robert Kirschner; Satinder P Singh; Pal Kiss; Brigitta C Brott; Tamas Simor; Ada Elgavish; Gabriel A Elgavish
Journal:  Invest Radiol       Date:  2012-05       Impact factor: 6.016

7.  Residual Thromboembolic Material in Cerebral Arteries after Endovascular Stroke Therapy Can Be Identified by Dual-Energy CT.

Authors:  A E Grams; M Knoflach; R Rehwald; J Willeit; M Sojer; E R Gizewski; B Glodny
Journal:  AJNR Am J Neuroradiol       Date:  2015-05-21       Impact factor: 3.825

Review 8.  Computed tomography scans in severe asthma: utility and clinical implications.

Authors:  Carolina Walker; Sumit Gupta; Ruth Hartley; Christopher E Brightling
Journal:  Curr Opin Pulm Med       Date:  2012-01       Impact factor: 3.155

9.  Spectral CT imaging as a new quantitative tool? Assessment of perfusion defects of pulmonary parenchyma in patients with lung cancer.

Authors:  Ying-Shi Sun; Xiao-Yan Zhang; Yong Cui; Lei Tang; Xiao-Ting Li; Ying Chen; Xiao-Peng Zhang
Journal:  Chin J Cancer Res       Date:  2013-12       Impact factor: 5.087

Review 10.  X-ray-computed tomography contrast agents.

Authors:  Hrvoje Lusic; Mark W Grinstaff
Journal:  Chem Rev       Date:  2012-12-05       Impact factor: 60.622

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.