Literature DB >> 20393235

Evaluation and optimization of the new EBT2 radiochromic film dosimetry system for patient dose verification in radiotherapy.

L Richley1, A C John, H Coomber, S Fletcher.   

Abstract

A new radiochromic film, the yellow Gafchromic EBT2, has been marketed as a drop-in replacement for the discontinued blue EBT film. In order to verify the manufacturer's claims prior to clinical use, EBT2 was characterized in transmission, and the less commonly used, reflection modes with an Epson Expression 10000XL A3 flatbed scanner. The red channel was confirmed to provide the greatest sensitivity and was used for all measurements. The post-irradiation darkening of the film was investigated, and the relative response was found to be dose dependent with higher doses stabilizing earlier than lower doses. After 13 h all dose levels had stabilized to within 1% of their value at 24 h. Uniformity of irradiated EBT2 films was within 0.8% and 1.2% (2SD of signal), in reflection and transmission modes, respectively. The light scattering effect, arising from the structure and thickness of EBT2, was found to give rise to an apparent scanner non-uniformity of up to 5.5% in signal. In reflection mode, differences of up to 1.2% were found between the signal obtained from a small film fragment (5 x 5 cm(2)) and the signal obtained from the same fragment bordered by extra film. Further work is needed to determine the origin of this effect, as there will be implications for reflection dosimetry of intensity modulated fields; reflection mode cannot yet be regarded as a viable alternative to transmission mode. Our results suggest that EBT2 film is a valid alternative, rather than a direct replacement for EBT film.

Entities:  

Mesh:

Year:  2010        PMID: 20393235     DOI: 10.1088/0031-9155/55/9/012

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  28 in total

1.  Dosimetric characterization and output verification for conical brachytherapy surface applicators. Part I. Electronic brachytherapy source.

Authors:  Regina K Fulkerson; John A Micka; Larry A DeWerd
Journal:  Med Phys       Date:  2014-02       Impact factor: 4.071

2.  A dosimetric phantom study of dose accuracy and build-up effects using IMRT and RapidArc in stereotactic irradiation of lung tumours.

Authors:  Jan Seppala; Sami Suilamo; Jarmo Kulmala; Pekka Mali; Heikki Minn
Journal:  Radiat Oncol       Date:  2012-05-31       Impact factor: 3.481

3.  A study on comparison of Gafchromic EBT2 film response under single and cumulative exposure conditions.

Authors:  K Ganapathy; P G G Kurup; V Murali; M Muthukumaran; J Velmurugan
Journal:  J Med Phys       Date:  2013-10

4.  Comparison of trigeminal neuralgia radiosurgery plans using two film detectors for the commissioning of small photon beams.

Authors:  Karina P Esparza-Moreno; Olivia A García-Garduño; Paola Ballesteros-Zebadúa; José M Lárraga-Gutiérrez; Sergio Moreno-Jiménez; Miguel A Celis-Lopez
Journal:  J Appl Clin Med Phys       Date:  2013-11-04       Impact factor: 2.102

5.  MAGAT gel and EBT2 film-based dosimetry for evaluating source plugging-based treatment plan in Gamma Knife stereotactic radiosurgery.

Authors:  Gopishankar Natanasabapathi; Vivekanandhan Subbiah; Shashank Sharad Kale; Goura Kishor Rath; S Senthilkumaran; Sanjay Thulkar; Vellaiyan Subramani; M A Laviraj; Raj Kishor Bisht; A K Mahapatra
Journal:  J Appl Clin Med Phys       Date:  2012-11-08       Impact factor: 2.102

6.  Evaluation of a single-scan protocol for radiochromic film dosimetry.

Authors:  Yoshinobu Shimohigashi; Fujio Araki; Masato Maruyama; Yuji Nakaguchi; Satoshi Kuwahara; Nozomu Nagasue; Yudai Kai
Journal:  J Appl Clin Med Phys       Date:  2015-03-08       Impact factor: 2.102

7.  Application of a dummy eye shield for electron treatment planning.

Authors:  Sei-Kwon Kang; Soah Park; Taejin Hwang; Kwang-Ho Cheong; Taejin Han; Haeyoung Kim; Me-Yeon Lee; Kyoung Ju Kim; Do Hoon Oh; Hoonsik Bae
Journal:  J Radiat Res       Date:  2012-08-21       Impact factor: 2.724

8.  An attempted substitute study of total skin electron therapy technique by using helical photon tomotherapy with helical irradiation of the total skin treatment: a phantom result.

Authors:  Chi-Ta Lin; An-Cheng Shiau; Hui-Ju Tien; Hsin-Pei Yeh; Pei-Wei Shueng; Chen-Hsi Hsieh
Journal:  Biomed Res Int       Date:  2013-07-31       Impact factor: 3.411

9.  Curtailing patient-specific IMRT QA procedures from 2D dose error distribution.

Authors:  Keita Kurosu; Iori Sumida; Hirokazu Mizuno; Yuki Otani; Michio Oda; Fumiaki Isohashi; Yuji Seo; Osamu Suzuki; Kazuhiko Ogawa
Journal:  J Radiat Res       Date:  2015-12-09       Impact factor: 2.724

10.  Amplitude gating for a coached breathing approach in respiratory gated 10 MV flattening filter-free VMAT delivery.

Authors:  Francis Viel; Richard Lee; Ermias Gete; Cheryl Duzenli
Journal:  J Appl Clin Med Phys       Date:  2015-07-08       Impact factor: 2.102

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.