Literature DB >> 20389349

Swept-source polarization-sensitive optical coherence tomography based on polarization-maintaining fiber.

Muhammad K Al-Qaisi1, Taner Akkin.   

Abstract

We present a swept-source polarization-sensitive optical coherence tomography system based on a polarization-maintaining fiber interferometer. The system produces reflectivity and birefringence information along a depth profile with a single sweep of the optical spectrum. Unlike single-mode fiber systems, retardance and relative optical axis orientation images are calculated without compensation. The source is a 45 mW polygon-based swept-source centered at 1290 nm and tuned at a rate of 28 kHz. The interferometer consists of a single polarization-maintaining coupler that utilizes balanced detection for improved performance. Characterization data shows that this system yields accurate measurements with high sensitivity (106.2 dB) comparable to conventional setups. Images of biological tissues with high dynamic range are demonstrated.

Entities:  

Mesh:

Year:  2010        PMID: 20389349     DOI: 10.1364/OE.18.003392

Source DB:  PubMed          Journal:  Opt Express        ISSN: 1094-4087            Impact factor:   3.894


  14 in total

1.  Polarization-sensitive interferometric synthetic aperture microscopy.

Authors:  Fredrick A South; Yuan-Zhi Liu; Yang Xu; Nathan D Shemonski; P Scott Carney; Stephen A Boppart
Journal:  Appl Phys Lett       Date:  2015-11-23       Impact factor: 3.791

2.  Conical scan polarization-sensitive optical coherence tomography.

Authors:  Zenghai Lu; Deepa Kasaragod; Stephen J Matcher
Journal:  Biomed Opt Express       Date:  2014-02-18       Impact factor: 3.732

3.  The posterior location of the dilator muscle induces anterior iris bowing during dilation, even in the absence of pupillary block.

Authors:  Rouzbeh Amini; Julie E Whitcomb; Muhammad K Al-Qaisi; Taner Akkin; Sara Jouzdani; Syril Dorairaj; Tiago Prata; Elena Illitchev; Jeffrey M Liebmann; Robert Ritch; Victor H Barocas
Journal:  Invest Ophthalmol Vis Sci       Date:  2012-03-09       Impact factor: 4.799

4.  Depth-encoded all-fiber swept source polarization sensitive OCT.

Authors:  Zhao Wang; Hsiang-Chieh Lee; Osman Oguz Ahsen; ByungKun Lee; WooJhon Choi; Benjamin Potsaid; Jonathan Liu; Vijaysekhar Jayaraman; Alex Cable; Martin F Kraus; Kaicheng Liang; Joachim Hornegger; James G Fujimoto
Journal:  Biomed Opt Express       Date:  2014-08-01       Impact factor: 3.732

5.  Quantitative single-mode fiber based PS-OCT with single input polarization state using Mueller matrix.

Authors:  Zhenyang Ding; Chia-Pin Liang; Qinggong Tang; Yu Chen
Journal:  Biomed Opt Express       Date:  2015-04-22       Impact factor: 3.732

6.  Complementary use of polarization-sensitive and standard OCT metrics for enhanced intraoperative differentiation of breast cancer.

Authors:  Jianfeng Wang; Yang Xu; Kelly J Mesa; Fredrick A South; Eric J Chaney; Darold R Spillman; Ronit Barkalifa; Marina Marjanovic; P Scott Carney; Anna M Higham; Z George Liu; Stephen A Boppart
Journal:  Biomed Opt Express       Date:  2018-11-28       Impact factor: 3.732

7.  Degradation in the degree of polarization in human retinal nerve fiber layer.

Authors:  Biwei Yin; Bingqing Wang; Henry G Rylander; Thomas E Milner
Journal:  J Biomed Opt       Date:  2014-01       Impact factor: 3.170

8.  Marker-Free Tracking of Facet Capsule Motion Using Polarization-Sensitive Optical Coherence Tomography.

Authors:  Amy A Claeson; Yi-Jou Yeh; Adam J Black; Taner Akkin; Victor H Barocas
Journal:  Ann Biomed Eng       Date:  2015-06-09       Impact factor: 3.934

9.  Reconstructing micrometer-scale fiber pathways in the brain: multi-contrast optical coherence tomography based tractography.

Authors:  Hui Wang; Adam J Black; Junfeng Zhu; Tyler W Stigen; Muhammad K Al-Qaisi; Theoden I Netoff; Aviva Abosch; Taner Akkin
Journal:  Neuroimage       Date:  2011-07-12       Impact factor: 6.556

10.  Spectral binning for mitigation of polarization mode dispersion artifacts in catheter-based optical frequency domain imaging.

Authors:  Martin Villiger; Ellen Ziyi Zhang; Seemantini K Nadkarni; Wang-Yuhl Oh; Benjamin J Vakoc; Brett E Bouma
Journal:  Opt Express       Date:  2013-07-15       Impact factor: 3.894

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.