| Literature DB >> 20387859 |
Ingmar Schoen1, Wei Hu, Enrico Klotzsch, Viola Vogel.
Abstract
Quantifying cellular forces relies on accurate calibrations of the sensor stiffness. Neglecting deformations of elastic substrates to which elastic pillars are anchored systematically overestimates the applied forces (up to 40%). A correction factor considering substrate warping is derived analytically and verified experimentally. The factor scales with the dimensionless pillar aspect ratio. This has significant implications when designing pillar arrays or comparing absolute forces measured on different pillar geometries during cell spreading, motility, or rigidity sensing.Entities:
Mesh:
Year: 2010 PMID: 20387859 PMCID: PMC2881340 DOI: 10.1021/nl100533c
Source DB: PubMed Journal: Nano Lett ISSN: 1530-6984 Impact factor: 11.189