AMS 700CX/CXM inflatable penile prosthesis has high mechanical reliability at long-term follow-up.

Dong Suk Kim1, Kwang Mo Yang, Hyun Jin Chung, Hyun Min Choi, Young Deuk Choi, Hyung Ki Choi.   

Abstract

INTRODUCTION: AMS 700CX/CXM inflatable penile prosthesis is increasingly applied for the treatment of erectile dysfunction (ED). However, there are a few long-term survival data of the inflatable penile prosthesis (IPP) over 10 years. AIM: To determine the long-term mechanical reliability of AMS 700CX/CXM inflatable penile prosthesis in patients with ED.
METHODS: A total of 438 consecutive patients with ED received implantation of an AMS 700CX/CXM penile prosthesis at our institution from January 1991 to April 2009. In 397 patients (90.7%), the medical records were available and current status of penile prosthesis could be obtained by a direct telephone interview. The overall and mechanical survival rates of penile prosthesis were evaluated using Kaplan-Meier method. MAIN OUTCOME MEASURES: Assessing the mechanical and overall survival rates of the AMS 700CX/CXM penile prosthesis using Kaplan-Meier analysis, and looking for clinical factors related to survival of the CX/CXM using log-rank test.
RESULTS: Mean age of 397 patients was 63.1 years (range, 24-93) and follow-up duration was 113 months (range 1-219). Eighty-two patients (20.6%) experienced mechanical failure at a median follow-up of 82 months. Mechanical survival rate of the penile prosthesis was 97.6%, 93.2% and 78.2% at 3, 5, and 10 years after implantation, respectively. 12 patients (3.0%) experienced nonmechanical failure including infections, tissue erosion resulting in cylinder protrusion at the meatus and chronic discomfort. Overall survival rate of the penile prosthesis was 95.0%, 91.0% and 75.5% at 3, 5, and 10 years after implantation, respectively. Patients with neurogenic cause for ED showed lower median overall survival of penile prosthesis compared with patients with non-neurogenic cause. Patient age, obesity, and diabetes mellitus had no association with overall survival of penile prosthesis after implantation.
CONCLUSIONS: The AMS 700CX/CXM could be accepted and applied in more patients as a reliable treatment alternative of ED.

Entities:  

Mesh:

Year:  2010        PMID: 20384938     DOI: 10.1111/j.1743-6109.2010.01801.x

Source DB:  PubMed          Journal:  J Sex Med        ISSN: 1743-6095            Impact factor:   3.802


  14 in total

Review 1.  A practical overview of considerations for penile prosthesis placement.

Authors:  Landon Trost; Philip Wanzek; George Bailey
Journal:  Nat Rev Urol       Date:  2015-12-01       Impact factor: 14.432

Review 2.  Dual implantation of penile prosthesis and ATOMS® system for post-prostatectomy erectile dysfunction and urinary incontinence: a feasibility study.

Authors:  Marco Falcone; Mirko Preto; Enrico Ammirati; Gideon Blecher; Roberto Carone; Paolo Gontero; Alessandro Giammò
Journal:  Int J Impot Res       Date:  2020-06-04       Impact factor: 2.896

3.  A population-based analysis of contemporary rates of reoperation for penile prosthesis procedures.

Authors:  Shaun Grewal; Joel Vetter; Steven B Brandes; Seth A Strope
Journal:  Urology       Date:  2014-04-29       Impact factor: 2.649

Review 4.  Current management of penile implant infections, device reliability, and optimizing cosmetic outcome.

Authors:  John J Mulcahy; Andrew Kramer; William O Brant; Justin L Parker; Paul E Perito; Jeremy B Myers; Richard Bryson; Meagan Dunne
Journal:  Curr Urol Rep       Date:  2014-06       Impact factor: 3.092

5.  Chronic pain associated with penile prostheses may persist despite revision or explantation.

Authors:  Jeffrey D Campbell; Ernest Pang Chan; Andrew Di Pierdominico; Serkan Karakus; Bruce Trock; Gerald B Brock; Arthur L Burnett
Journal:  Can Urol Assoc J       Date:  2022-02       Impact factor: 1.862

6.  Long-term survival and patient satisfaction with inflatable penile prosthesis for the treatment of erectile dysfunction.

Authors:  Yoon Seob Ji; Young Hwii Ko; Phil Hyun Song; Ki Hak Moon
Journal:  Korean J Urol       Date:  2015-06-02

Review 7.  Prevention, identification, and management of post-operative penile implant complications of infection, hematoma, and device malfunction.

Authors:  Timothy K O'Rourke; Alexander Erbella; Yu Zhang; Matthew S Wosnitzer
Journal:  Transl Androl Urol       Date:  2017-11

Review 8.  Narrative review of penile prosthetic implant technology and surgical results, including transgender patients.

Authors:  Michael Polchert; Brian Dick; Omer Raheem
Journal:  Transl Androl Urol       Date:  2021-06

Review 9.  Penile prosthesis surgery in the management of erectile dysfunction.

Authors:  Hossein Sadeghi-Nejad; Mina Fam
Journal:  Arab J Urol       Date:  2013-07-02

Review 10.  Korean Society for Sexual Medicine and Andrology (KSSMA) Guideline on Erectile Dysfunction.

Authors:  Ji Kan Ryu; Kang Su Cho; Su Jin Kim; Kyung Jin Oh; Sung Chul Kam; Kyung Keun Seo; Hong Seok Shin; Soo Woong Kim
Journal:  World J Mens Health       Date:  2013-08-31       Impact factor: 5.400

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.