Literature DB >> 2038185

Alterations in body fluid content can be detected by bioelectrical impedance analysis.

M R Scheltinga1, D O Jacobs, T D Kimbrough, D W Wilmore.   

Abstract

The electrical resistance across the whole body and its segments to the conduction of a weak alternating current was determined in human subjects under three different conditions: (1) during bed rest, (2) during infusion of 1 liter of saline, and (3) during donation of 1 unit of blood. During bed rest, extracellular and total body water were measured by dilution of bromide and heavy water, respectively. Electrical resistance obtained from electrodes placed on proximal portions of extremities ("proximal resistance") accounted for less than 50% of that determined by electrodes positioned on routinely used portions of a hand and foot ("whole body resistance"). Following saline infusion, resistance determined from the whole body and all its segments fell (P less than 0.001); the magnitude of the drop in both proximal and whole body resistance was inversely related to the volume of total body water (TBW) (r = -0.82, P less than 0.002, and r = -0.73, P less than 0.01, respectively). In contrast, blood donation was associated with significantly increased resistance at both measurement sites. TBW predicted from anthropometrics was inversely related to both proximal (r = -0.90, P less than 0.001) and whole body resistance (r = -0.75, P less than 0.001). Bioelectrical impedance analysis is a simple technique which may be useful in monitoring minimal alterations in TBW. Furthermore, altered fluid status may be predicted more accurately by changes in proximal resistance compared to changes in traditionally used whole body resistance.

Entities:  

Mesh:

Substances:

Year:  1991        PMID: 2038185     DOI: 10.1016/0022-4804(91)90025-h

Source DB:  PubMed          Journal:  J Surg Res        ISSN: 0022-4804            Impact factor:   2.192


  8 in total

1.  Longitudinal agreement of four bioimpedance analyzers for detecting changes in raw bioimpedance during purposeful weight gain with resistance training.

Authors:  Matthew T Stratton; Robert W Smith; Patrick S Harty; Christian Rodriguez; Baylor A Johnson; Jacob R Dellinger; Abegale D Williams; Sarah J White; Marqui L Benavides; Grant M Tinsley
Journal:  Eur J Clin Nutr       Date:  2021-03-16       Impact factor: 4.016

2.  A comparison of three bioelectrical impedance analyses for predicting lean body mass in a population with a large difference in muscularity.

Authors:  Noriko Ishiguro; Hiroaki Kanehisa; Masae Miyatani; Yoshihisa Masuo; Tetsuo Fukunaga
Journal:  Eur J Appl Physiol       Date:  2004-12-17       Impact factor: 3.078

3.  Anabolic therapy with growth hormone accelerates protein gain in surgical patients requiring nutritional rehabilitation.

Authors:  T A Byrne; T B Morrissey; C Gatzen; K Benfell; T V Nattakom; M R Scheltinga; M S LeBoff; T R Ziegler; D W Wilmore
Journal:  Ann Surg       Date:  1993-10       Impact factor: 12.969

Review 4.  From space to Earth: advances in human physiology from 20 years of bed rest studies (1986-2006).

Authors:  A Pavy-Le Traon; M Heer; M V Narici; J Rittweger; J Vernikos
Journal:  Eur J Appl Physiol       Date:  2007-07-28       Impact factor: 3.078

5.  A new treatment for patients with short-bowel syndrome. Growth hormone, glutamine, and a modified diet.

Authors:  T A Byrne; R L Persinger; L S Young; T R Ziegler; D W Wilmore
Journal:  Ann Surg       Date:  1995-09       Impact factor: 12.969

6.  Hemodynamic and biochemical alterations in dogs with lymphoma after induction of chemotherapy.

Authors:  D M Fine; K Selting; R C Backus; N F Rossi; M W Harmon; H E Durham; A W Spier
Journal:  J Vet Intern Med       Date:  2014-03-21       Impact factor: 3.333

7.  Bioelectrical Impedance Analysis Is Not Sufficient for Determining Water Deficit in Hypernatremic Patients.

Authors:  Se-Hee Yoon; Seul-Gi Kim; In-Beom Jeong; Won-Min Hwang; Sung-Ro Yun
Journal:  Med Sci Monit       Date:  2019-11-09

8.  Accuracy of Estimated Bioimpedance Parameters with Octapolar Segmental Bioimpedance Analysis.

Authors:  Fanglin Jiang; Saizhao Tang; Jin-Jong Eom; Keon-Hyoung Song; Hyeoijin Kim; Sochung Chung; Chul-Hyun Kim
Journal:  Sensors (Basel)       Date:  2022-03-31       Impact factor: 3.576

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.