Literature DB >> 20381808

On-line solid phase extraction fast liquid chromatography-tandem mass spectrometry for the analysis of bisphenol A and its chlorinated derivatives in water samples.

H Gallart-Ayala1, E Moyano, M T Galceran.   

Abstract

In this study an on-line column-switching fast LC-MS/MS method was developed to analyze bisphenol A (BPA) and its chlorinated derivatives in water. Fast liquid chromatographic separation was performed on a C18 reversed phase column based on fused-core particle technology (2.7 microm particle size) providing analysis times shorter than 3 min and high peak efficiencies. The main benefit of this LC system is that it can easily be hyphenated to a conventional on-line preconcentration device allowing the direct analysis of water samples without any pretreatment at concentrations levels down to 60 ng L(-1) and preventing contaminations frequently reported in the analysis of BPA. This on-line SPE fast LC system was coupled to a triple quadrupole mass spectrometer operating in enhanced mass resolution mode (Q1 FWHM=0.7 Th, Q3 FWHM=0.1 Th) in order to minimize interferences and chemical noise. This highly sensitive and selective method was successfully employed to analyze BPA and its chlorinated derivatives in water samples. 2010 Elsevier B.V. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20381808     DOI: 10.1016/j.chroma.2010.03.028

Source DB:  PubMed          Journal:  J Chromatogr A        ISSN: 0021-9673            Impact factor:   4.759


  3 in total

1.  Quantification of bisphenol A, 353-nonylphenol and their chlorinated derivatives in drinking water treatment plants.

Authors:  Antoine Dupuis; Virginie Migeot; Axelle Cariot; Marion Albouy-Llaty; Bernard Legube; Sylvie Rabouan
Journal:  Environ Sci Pollut Res Int       Date:  2012-05-31       Impact factor: 4.223

2.  Hepatic metabolism of chlorinated derivatives of bisphenol A (ClxBPA) and interspecies differences between rats and humans.

Authors:  N Plattard; N Venisse; P Carato; A Dupuis; Sami Haddad
Journal:  Arch Toxicol       Date:  2022-01-24       Impact factor: 5.153

3.  Biomonitoring method for bisphenol A in human urine by ultra-high-performance liquid chromatography-tandem mass spectrometry.

Authors:  David J Anderson; Eric M Brozek; Kyley J Cox; Christina A Porucznik; Diana G Wilkins
Journal:  J Chromatogr B Analyt Technol Biomed Life Sci       Date:  2014-02-02       Impact factor: 3.205

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.