Measurement of 25-OH-vitamin D in human serum using liquid chromatography tandem-mass spectrometry with comparison to radioimmunoassay and automated immunoassay.

Johannes M W van den Ouweland1, Antonius M Beijers, Pierre N M Demacker, Henny van Daal.   

Abstract

The plasma 25-OH vitamin D concentration is a reliable biomarker for vitamin D status but assay's variability makes adequate monitoring of vitamin D status difficult. We employed isotope-dilution liquid chromatography (LC) tandem-mass spectrometry (MS/MS) for the measurement of both 25-OH vitamin D3 and 25-OH vitamin D2 in human serum. Hexadeuterium labelled 25-OH vitamin D3 internal standard (IS) was added to calibrators (prepared in phosphate-buffered saline with 60 g/L albumin), controls or patient sera and 25-OH vitamin D metabolites were released from vitamin D binding protein by adding sodium hydroxide prior to protein precipitation by acetonitrile/methanol (9:1, v/v). Subsequent off-line solid-phase extraction was followed by chromatographic separation on a C-18 column using a water/methanol/ammonium acetate gradient. Detection was by Atmospheric Pressure Electrospray Ionisation (AP-EI) followed by selected reaction monitoring. We compared the LC-MS/MS assay to the DiaSorin radioimmunoassay (RIA) and a recently re-standardised version of an automated electrochemiluminescent immunoassay (ECLIA) from Roche Diagnostics. We also analysed external quality control samples from the International Vitamin D External Quality Assessment Scheme (DEQAS) for comparison with other participating laboratories using LC-MS. The method was linear from 5 to at least 550 nmol/L with intra- and interday CV's < or = 6% for both 25-OH vitamin D3 and 25-OH vitamin D2. Recoveries ranged between 94.9 and 106.9% for 25-OH vitamin D3 and 82.7 and 100.3% for 25-OH vitamin D2. Our results for the DEQAS serum pools averaged -7.2% from the overall LC-MS method mean. The DiaSorin RIA agreed well with the LC-MS/MS method (r(2)=0.90; average bias 1.61 nmol/L), the Roche ECLIA considerably disagreed (r(2)=0.58; bias 10.13 nmol/L). This LC-MS/MS method is reliable and robust for the measurement of both 25-OH vitamin D3 and 25-OH vitamin D2 in human serum. 2010 Elsevier B.V. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20381436     DOI: 10.1016/j.jchromb.2010.03.035

Source DB:  PubMed          Journal:  J Chromatogr B Analyt Technol Biomed Life Sci        ISSN: 1570-0232            Impact factor:   3.205


  39 in total

1.  Individuals with exceptional longevity manifest a delayed association between vitamin D insufficiency and cognitive impairment.

Authors:  Sofiya Milman; Micol Schulder-Katz; Jennifer Deluty; Molly E Zimmerman; Jill P Crandall; Nir Barzilai; Michal L Melamed; Gil Atzmon
Journal:  J Am Geriatr Soc       Date:  2014-01-02       Impact factor: 5.562

2.  Prevalence and Predictors of Low Serum 25-Hydroxyvitamin D among Female African-American Breast Cancer Survivors.

Authors:  Patricia Sheean; Claudia Arroyo; Jennifer Woo; Linda Schiffer; Melinda Stolley
Journal:  J Acad Nutr Diet       Date:  2018-01-02       Impact factor: 4.910

3.  Vitamin D status among preterm and full-term infants at birth.

Authors:  Heather H Burris; Linda J Van Marter; Thomas F McElrath; Patrik Tabatabai; Augusto A Litonjua; Scott T Weiss; Helen Christou
Journal:  Pediatr Res       Date:  2013-10-11       Impact factor: 3.756

Review 4.  Vitamin D in the new millennium.

Authors:  Sunil J Wimalawansa
Journal:  Curr Osteoporos Rep       Date:  2012-03       Impact factor: 5.096

5.  Associations between physical activity and bone structure in older adults: does the use of self-reported versus objective assessments of physical activity influence the relationship?

Authors:  C-A Ng; L B McMillan; B Beck; L Humbert; P R Ebeling; D Scott
Journal:  Osteoporos Int       Date:  2019-11-13       Impact factor: 4.507

6.  Measurement of serum total vitamin D (25-OH) using automated immunoassay in comparison [corrected] with liquid chromatography tandem-mass spectrometry.

Authors:  Sang-Yong Shin; Min-Jung Kwon; Junghan Song; Hyosoon Park; Hee-Yeon Woo
Journal:  J Clin Lab Anal       Date:  2013-07       Impact factor: 2.352

Review 7.  Vitamin D and metabolites measurement by tandem mass spectrometry.

Authors:  Johannes M W van den Ouweland; Michael Vogeser; Silvia Bächer
Journal:  Rev Endocr Metab Disord       Date:  2013-06       Impact factor: 6.514

Review 8.  Bioactive food components and cancer-specific metabonomic profiles.

Authors:  Young S Kim; John A Milner
Journal:  J Biomed Biotechnol       Date:  2010-11-11

9.  Serum 25-hydroxyvitamin D levels and incident diabetes mellitus type 2: a competing risk analysis in a large population-based cohort of older adults.

Authors:  Ben Schöttker; Christian Herder; Dietrich Rothenbacher; Laura Perna; Heiko Müller; Hermann Brenner
Journal:  Eur J Epidemiol       Date:  2013-01-26       Impact factor: 8.082

10.  A simple, rapid atmospheric pressure chemical ionization liquid chromatography tandem mass spectrometry method for the determination of 25-hydroxyvitamin D2 and D3.

Authors:  Uttam Garg; Ada Munar; Clinton Frazee; David Scott
Journal:  J Clin Lab Anal       Date:  2012-09       Impact factor: 2.352

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.