OBJECTIVE: The purpose of this study was to evaluate the effect of different filler sizes and shapes on the surface roughness of experimental resin-composite series. MATERIAL AND METHODS: Thirty-three disc-shaped specimens of the series (Spherical-RZD 102, 105, 106, 107, 114 and Irregular-RZD 103, 108, 109, 110, 111, 112) were prepared in a split Teflon mold and irradiated with an halogen light-curing unit (450 mW/cm(2) for 40 s) at both top and bottom surfaces. The specimens were stored for 3 months in distilled water. The surface roughness values in form of surface finish-vertical parameter (R(a)), maximum roughness depth (R(max)) and horizontal roughness parameter (S(m)) were recorded using a contact profilometer. The data were analyzed by one-way ANOVA and the means were compared by Scheffé post-hoc test (alpha=0.05). RESULTS: The lowest surface roughness (R(a)) was observed in S-100 (0.079+/-0.013), while the roughest surface was noted in I-450/700/1000 (0.125+/-0.011) and I-450/1000 (0.124+/-0.004). The spherical-shape series showed the smoothest surface finish compared to the irregular-shape ones with higher significant difference (p>0.05). The vertical surface roughness parameter (R(a)) values increased as the filler size increased yielding a linear relation (r(2)=0.82). On the contrary, the horizontal parameter (S(m)) was not significantly affected by the filler size (r(2)=0.24) as well as the filler shape. CONCLUSIONS: Filler particle's size and shape have a great effect on the surface roughness parameters of these composite series.
OBJECTIVE: The purpose of this study was to evaluate the effect of different filler sizes and shapes on the surface roughness of experimental resin-composite series. MATERIAL AND METHODS: Thirty-three disc-shaped specimens of the series (Spherical-RZD 102, 105, 106, 107, 114 and Irregular-RZD 103, 108, 109, 110, 111, 112) were prepared in a split Teflon mold and irradiated with an halogen light-curing unit (450 mW/cm(2) for 40 s) at both top and bottom surfaces. The specimens were stored for 3 months in distilled water. The surface roughness values in form of surface finish-vertical parameter (R(a)), maximum roughness depth (R(max)) and horizontal roughness parameter (S(m)) were recorded using a contact profilometer. The data were analyzed by one-way ANOVA and the means were compared by Scheffé post-hoc test (alpha=0.05). RESULTS: The lowest surface roughness (R(a)) was observed in S-100 (0.079+/-0.013), while the roughest surface was noted in I-450/700/1000 (0.125+/-0.011) and I-450/1000 (0.124+/-0.004). The spherical-shape series showed the smoothest surface finish compared to the irregular-shape ones with higher significant difference (p>0.05). The vertical surface roughness parameter (R(a)) values increased as the filler size increased yielding a linear relation (r(2)=0.82). On the contrary, the horizontal parameter (S(m)) was not significantly affected by the filler size (r(2)=0.24) as well as the filler shape. CONCLUSIONS: Filler particle's size and shape have a great effect on the surface roughness parameters of these composite series.
Surface roughness property of the restoratives has long been recognized as a parameter
of high clinical relevance for plaque accumulation, staining susceptibility and wear.
Increasing esthetic demands from the patients resulted in a wide use of resin composites
in dental practice. The structures of resin matrix, coupling agent and the
characteristics of filler particles have a direct impact on the surface smoothness of
resin composites[6]. The main intrinsic
factor that affects surface smoothness of any composite is filler component. The type of
inorganic particles, size of fillers, and extend of filler loading are considered the
most important factors. Various experimental composites have been introduced aiming to
comparatively evaluate their properties in order to increase their optimum clinical
performance[1,2,5].Highly esthetic and polished surfaces of resin composites can be obtained by minimizing
the filler size. The main concept of creating composites with nanofiller particles is to
have superior properties, such as strength, stiffness as well as color and thermal
stability, to the conventional ones. Lately, one of the important advances in
nanotechnology science is their application to dental resin composites as in Filtek
Supreme XT[7,10,11]. Nanofill composites
are composed of nanomer or nanocluster, whereas nanohybrids are hybrid resin composites
with nanofiller in a prepolymerized filler form[11]. Nanofill composites are claimed to offer ultimate esthetics,
excellent wear resistance and strength[10]. Surface characteristics of composites in form of roughness,
topography and texture have been considered as important parameters of clinical
relevance for wear resistance, plaque retention and discoloration susceptibility. In
vitro studies have indicated that nanofill resin composites showed favorable mechanical
properties as optical and gloss characteristics, reduced polymerization shrinkage,
higher surface quality and superior polish[18,21].Several studies have been made to study the effects of dental composite’s microstructure
on its properties[1,10]. Filler component in term of size, distribution,
geometry and volume fraction have been investigated extensively[1,20]. Fundamental understandings of the factors that affect the superior
clinical performance of the resin composites can assist in more refinement of these
materials during manufacturing. Therefore, this study is aimed to evaluate the effect of
different filler sizes ranged from 100 to 1500 nm and geometry (spherical and irregular)
on the surface characteristics of experimental resin composite series. The surface
roughness was measured from both vertical and horizontal dimensions to give more details
on the surface structure of the composite materials. The null hypotheses stated that;
(a) there are no differences between surface roughness values of the experimental
composite series, and (b) there is no correlation between both vertical as well as
horizontal surface roughness parameters and the increase in filler particle size.
MATERIAL AND METHODS
Eleven series of experimental resin composites based on different filler particle size
formulations (range of 100-1500 nm) and two geometries (spherical and irregular) were
investigated (Table 1). These series comprised
Bis-GMA, UDMA, TEGDMAresin matrix, 0.33% camphorquinone and barium glass particles of
56.7% filler volume fraction. These particulate dispersed phases were systematically
graded in size and treated with a silane coupling agent
(methacryloxypropyltrimethoxysilane). The spherical particles were silica and made from
solution, while the irregular particles were ground glass melts (Ba-Al-B-silicate
glass).
Table 1
Experimental composite series formulations
Resin-composite series (Batch
#)
Code
Filler Particles
Matrix
Manufacturer
Size (nm)
Shape
Wt%
Vol%
RZD 102
S-100
100
Spherical
72.3
56.7
Bis-GMA, UDMA, TEGDMA
Ivoclar Vivadent, Schaan, Liechtenstein
RZD 107
S-250
250
Spherical
72.6
56.7
RZD 106
S-500
500
Spherical
72.6
56.7
RZD 105
S-1000
1000
Spherical
72.5
56.7
RZD 114
S-100/250/1000
100:250:1000 (1:1:2)
Spherical
72.0
56.7
RZD 103
I-450
450
Irregular
76.4
56.7
RZD 108
I-700
700
Irregular
76.4
56.7
RZD 109
I-1000
1000
Irregular
76.4
56.7
RZD 110
I-1500
1500
Irregular
76.4
56.7
RZD 111
I-450/1000
450:1000 (1:3)
Irregular
76.4
56.7
RZD 112
I-450/700/1000
450:700:1000 (1:1:3)
Irregular
76.4
56.7
Thirty-three disc-shaped specimens (10 mm diameter x 2 mm thick) of the composite series
were fabricated at room temperature in a split Teflon mold (n=3). The uncured material
was gently packed inside the mold which was covered from both sides with thin
transparent Mylar strips (KerrHawe Neos Dent, Bioggio, Switzerland). The unset specimen
inside the mold assembly was pressed between two microscope glass slides (76 x 26 x 1 mm
Surgipath glass) to extrude the excess of the material resulting in a flat surface.The composite series were irradiated by a conventional halogen light-curing unit
(Optilux 501, Demetron/Kerr, Danbury, CT, USA) at 450 mW/cm[2] for 40 s at both top and bottom surfaces. The specimens
were exposed to the same amount of irradiation after removal of the glass slides and
Mylar strips. The power density of the curing-unit was monitored with an external
radiometer (Demetron/Kerr, Danbury, CT, USA) before curing the specimens. Then the cured
specimens were removed from the mold and stored in dark bottles of 30 ml capacity
containing distilled water at 37± 0.5ºC for 24 h to complete
polymerization of the material. Afterwards, they were lightly finished manually from the
top-surface with 1000-grit silicon carbide (SiC) abrasive paper under running water and
polished with 1500 SiC paper as well as 5 and 1 µm aluminum oxide slurry pastes for 5
sec each step. This will allow removal of a weak resin-rich layer yielding a uniform
surface finish. The samples were sonically cleaned in distilled water for 15 min, stored
for 3 months at 37ºC incubator, and were then blotted dry with an absorbent paper
before measurement of roughness parameters.The examined surface was assessed for any artifacts such as pores or scratches by
stereo-microscope (Meiji Techno America, San Jose, CA, USA) because those with defects
were discarded and replaced with new ones. The surface roughness parameters were
measured by a contact profilometer (Surfcorder SE 1700; Kosaka Corp., Tokyo, Japan)
equipped with a 5-µm radius diamond-tipped stylus that was attached to a pickup head.
The stylus traversed the surface of the specimen at a constant speed of 0.5 mm/s with a
force of 4 mN and automatic return. Each specimen was traced in three parallel locations
near the center across the top-surface with an evaluation length of 4 mm. The data were
filtered with a cut-off (λc) of 0.8 mm (Gauss profile-Filter) and the tracings
were 0.8 mm in length because the standard JIS94 was selected as a measuring profile.
Leveling of all parts of the apparatus can be achieved by adjusting the pick-up head
knob.Preparation and finishing of specimens were performed by only one operator. The accurate
performance of the profilometer was checked periodically by the use of a calibration
block. The surface irregularity signals were transformed into digital values that
monitored on a computer. The following roughness parameters were selected to describe
the surface texture of the investigated composite series[4,12]. The parameters
are illustrated graphically in Figure 1.
Figure 1
Surface roughness parameters selected, Ra, Rmax, and Sm
Surface roughness parameters selected, Ra, Rmax, and SmRa is the arithmetical average height of surface component (profile)
irregularities from the mean line within the measuring length used to describe the
vertical dimension of roughness.Sm is the mean spacing between peaks known as roughness spacing parameter that used to
describe the horizontal dimension of roughness.Rmax is the maximum roughness depth or the largest peak-to-valley depth over
the sampling length. It was recorded to determine any major surface defect.The data were analyzed statistically using the SPSS software (Version 11.5, SPSS Inc.,
Chicago, IL, USA) and graphically plotted by Sigma (Σ) Plot (SigmaPlot 2002 ver. 8, SPSS
Inc., Illinois, USA). One-way analysis of variance (ANOVA) followed by Scheffé
post-hoc test were used to detect the area of significant differences for surface
roughness parameters between the composite series at α=0.05. A regression
analysis was used to determine possible correlation between different particle sizes of
these series and the vertical surface finish (Ra) as well as the horizontal
(Sm) parameters.
RESULTS
The mean and standard deviation values (µm) of surface roughness parameters
(Ra, Sm, Rmax) for each composite series are summarized in
Table 2. One-way ANOVA was used to delineate
the areas of significant differences between the composite series. It revealed highly
significant differences between the materials for the Ra surface roughness
parameter (p<0.05). Multiple comparisons Scheffé pos-hoc test showed high
significant differences between S-250 as well as I-450 and the following irregular-shape
filler composite series; monomodal (I-1500), bimodal (I-450/1000), trimodal (I-450/
700/1000). Also there were significant differences between S-100 and all the spherical
as well as the irregular series except with I-450 and S-250. Moreover, there were no
significant differences between all composite series investigated for Rmax
and Sm roughness parameters (p>0.05).
Table 2
Mean and standard deviation (sd) of surface roughness parameters (pm) for the
experimental composite series
Roughness parameter
Surface roughness mean & sd
(µm) of the experimental resin-composite series
RZD
RZD
RZD
RZD
RZD
RZD
RZD
RZD
RZD
RZD
RZD
102
107
106
105
114
103
108
109
110
111
112
Ra
0.079
0.096
0.106
0.106
0.117
0.093
0.105
0.117
0.121
0.124
0.125
(0.013)a
(0.002)ab
(0.010)bc
(0.011)bc
(0.005)bc
(0.008)ab
(0.009)bc
(0.010)bc
(0.004)c
(0.004)c
(0.011)c
Sm
267
178
158
212
138
157
176
113
147
142
135
(51)b
(14)ab
(17)ab
(93)ab
(19)ab
(81)ab
(26)ab
(15)a
(42)ab
(25)ab
(40)ab
Rmax
0.794
1.096
0.792
1.211
2.379
1.421
0.861
1.374
1.103
0.754
1.259
(0.178)a
(0.751)a
(0.073)a
(0.541)a
(0.334)a
(1.049)a
(0.131)a
(0.393)a
(0.411 )a
(0.489)a
(0.101)a
*Superscript letters indicate homogenous subsets (within which
p>0.05) where comparison has been made with respect to
different composite series.
*Superscript letters indicate homogenous subsets (within which
p>0.05) where comparison has been made with respect to
different composite series.Among the experimental series investigated, the lowest surface roughness (Ra)
was noted in monomodal spherical-shape series; S-100 (0.079±0.013) and S-250
(0.096±0.002). On the other hand, the roughest surface (Ra) was found
in bi- and tri-modal irregular-shape composite series I-450/1000 (0.124±0.004)
and I-450/700/ 1000 (0.125±0.011) followed by spherical trimodal series
(S-100/250/1000) (Figure 2). Additionally, the
latter series expressed the highest Rmax value (2.379±0.334) whereas
S-500 monomodal series showed the lowest value (0.792±0.073). Moreover, I-1000
showed a low Sm value (113±15) compared to S-100 (267±51) (Figure 3). However, the most commonly used parameter
to describe roughness is the vertical one (Ra); and it is compared with the
horizontal parameter (Sm).
Figure 2
Surface roughness, Ra (µm) of the mono-, bi- and multi-modal
experimental composite series
Figure 3
Surface roughness, Sm (µm) of the mono-, bi- and multi-modal experimental
composite series
Surface roughness, Ra (µm) of the mono-, bi- and multi-modal
experimental composite seriesSurface roughness, Sm (µm) of the mono-, bi- and multi-modal experimental
composite seriesThe regression analysis showed an increase in Ra values with increasing
filler particle size yielded a high correlation of both spherical and irregular series
(r[2]=0.82), as shown in Figure 4. However, the same analysis demonstrated a
non-significant correlation between the increase of filler size and the Sm parameter
giving a non-linear regression (r[2]=0.24), as illustrated in Figure
5.
Figure 4
Vertical surface roughness, Ra (µm) regression of the experimental
composite series
Figure 5
Horizontal surface roughness, Sm (µm) regression of the experimental
composite series
Vertical surface roughness, Ra (µm) regression of the experimental
composite seriesHorizontal surface roughness, Sm (µm) regression of the experimental
composite seriesThe spherical-shape composite series clearly showed the smoothest surface finish, while
the irregular-shape composite series provided the roughest one. In both filler
geometries, the surface roughness values gradually increased with increasing the filler
size. Moreover, the multimodal series expressed the highest roughness values than the
monomodal series especially when they are irregular in shape.
DISCUSSION
Several methods are currently available to measure the surface texture of any material
including contact stylus tracing, scanning electron microscopy, laser reflectivity,
non-contact laser metrology and compressed air measuring[15]. The most recent method is atomic force
microscopy (AFM) and the most common one is the contact stylus tracing[22]. The latter method was used in the
current study because it was fast, simple and reliable for comparative assessment of
surface roughness property.In the present study, the resin-rich layer that forms a smooth surface resulted from
adaptation of Mylar strip during specimen fabrication was removed by light
finishing-polishing procedures. This unpolished surface is usually smoother than the
polished one due to the former contain more polymer matrix than the latter. A previous
study, however, has shown no significant difference in surface roughness between
polished and unpolished surfaces for mainly nanofill resin composites[17].Vertical roughness parameters such as Ra, Rmax, Rt and
Rz are used to describe the surface irregularities by their amplitudes
only. The roughness height (Ra) parameter is merely used by many
investigators to estimate the surface quality of resin composite materials. In this
study, the spacing parameter (Sm) that measures the horizontal feature of the surface
was recorded. Additionally, Rmax was monitored to determine if any major
surface defect on the surface was encountered.The roughness parameters are dependent on several factors such as filler size,
percentage of surface area occupied by filler particles, hardness, degree of conversion
of polymer to resin matrix and filler/matrix interaction, as well as stability of silane
coupling agent[3,5,8]. Eleven
different composite series containing spherical and irregular shape fillers ranged from
100 to 1500 nm and based on mono-, bi- and multimodal (trimodal) filler formulations
were studied. The differences in the surface roughness parameters of these composite
series might be ascribed to variation in their filler size, geometry and
composition.In the current study, the surface roughness (Ra) values of the composite
series were ranged between 0.079 and 0.125 µm. The monomodal spherical-shape series with
a small particle size (S-100) expressed the lowest surface roughness among the materials
investigated, while the multimodal irregular-shape series (I-450/700/ 1000) with
different particles sizes showed the highest roughness value.On the scale of filler components, variation in the interparticle spacing, filler
distribution, presence of filler agglomeration and clusters, as well as the quality of
filler adhesion to the matrix may have an effect on the surface characteristics of these
series. Currently, smaller size filler particles can be adhered to resin matrix, thus
providing a smoother surface finish[17].
It has been shown that the introduction of finer particles among larger ones will result
in reduction of interparticle spacing and the amount of resin matrix, thus maximizing
the overall properties of the material[5]. Decreased interparticle spacing caused by reduced filler size may
leads to reduction in strain localization around the filler, thus reducing the fatigue
failure[9,19]. The concept of multimodal fillers enables the
composites to obtain high filler loading and allows a strong integration of small
particles into resin matrix that can be eroded by breaking off small individual
particles rather than large ones[13,19,20].These composite series are dependent on variation in their filler component that differs
mainly in size and shape. The low surface roughness of the spherically based composite
series could be attributed to that these particles were made from silica, while the
irregular particles were ground glass melts. The spherical particles may allow more flow
and stress relaxation of the material compared to irregular ones. Theoretically, it was
found that spherical particles can be debonded more easily from the matrix than the
irregular fillers[19,23].In this study, it was noted that the surface roughness values increased with the
increase of the filler particle size and also with irregular-shape fillers. This is in
agreement with a previous study concluding that a higher surface roughness is associated
with larger filler particles[3,14,16]. It was evident that the irregular filler series of the same filler
size as I-1000 is rougher than the S-1000. The variation in particle size as in
multimodal series may affect the surface roughness of the material through their surface
area and interparticle spacing.As the filler volume fractions were the same in all the series (56.7% vol), the possible
explanation for higher surface roughness of multimodal-irregular than
multimodal-spherical is that the latter has smaller distance between neighboring
particles as compared to the coarser filler particles. Moreover, larger particles
especially the irregular ones tended to protrude from the surface, which may result in
their high surface roughness. From microstructure perspective, the stress concentration
around the irregular fillers may lead to their pull-out from the surface, thus
increasing the surface roughness of these series. Another possible explanation could be
related to the formation of filler clumping-clusters in multimodal series that may
contribute to their high roughness values in comparison to monomodal series. This can be
in accord with a previous finding suggested that nanofilled composite expressed high
wear resistance and had lower roughness level compared to nanohybrid
composites[2,17,19].On the other hand, the highest roughness values presented by the horizontal parameter
(Sm) were recorded for the monomodal spherical series (S-100), which expressed the
lowest vertical roughness value (Ra). The smaller size fillers provided less
vertical dimension; however, they can result in filler agglomeration which may
responsible for increasing the horizontal dimension of the roughness profile. Another
possible explanation can be related to the ease in flattening of the spherical fillers
during lightfinishing that was done in the process of specimen preparation.However, the lowest Sm value was demonstrated by monomodal irregular type of series
(I-1500), which can be explained by presence of surface projection irregularities that
may minimize the average spacing between peaks. Moreover, the trimodal irregular series
showed an intermediate Sm value between the upper and lower range that demonstrated in
the current study. This can be attributed to the presence of multi-filler sizes that
minimize somewhat the inter-particle spaces. Therefore, the variation between these two
surface roughness parameters (vertical and horizontal) for both spherical and irregular
based composite series may be related to the function of their microstructure.Further investigation is needed to study the same series with a more sensitive device
such as a 3-D atomic force microscopy (AFM), which may give a detailed illustration of
the surface roughness especially for these composites.
CONCLUSIONS
Within the limitations of this in vitro study, the following conclusions can be
made:1-The first null hypothesis is rejected since a significant variation in the surface
roughness values of the experimental composite series was found.2-Filler particle size plays an important role in the surface characteristics of the
experimental composite series. The vertical roughness value (Ra) increases as
the filler particle size is increased, thus rejecting the second null hypothesis
(regarding vertical roughness).3-The horizontal surface parameter (Sm) of the series is insignificantly correlated with
the increase in the filler particle size, therefore, the second null hypothesis could
not be rejected (regarding horizontal roughness).4-Monomodal series with spherical and small size fillers showed the smoothest surface,
while multimodal series with irregular and variant filler sizes exhibited the roughest
surface parameters.