Literature DB >> 203784

Quantitative electrical-impedance plethysmography for pulmonary oedema.

M R Khan, S K Guha, S Tandon, S B Roy.   

Abstract

Entities:  

Mesh:

Year:  1977        PMID: 203784     DOI: 10.1007/bf02457920

Source DB:  PubMed          Journal:  Med Biol Eng Comput        ISSN: 0140-0118            Impact factor:   2.602


× No keyword cloud information.
  15 in total

1.  Transthoracic electrical impedance; quantitative evaluation of a non-invasive measure of thoracic fluid volume.

Authors:  R V Luepker; J R Michael; J R Warbasse
Journal:  Am Heart J       Date:  1973-01       Impact factor: 4.749

2.  Monitoring the chest with impedance.

Authors:  J M Van de Water; B E Mount; J R Barela; R Schuster; F S Leacock
Journal:  Chest       Date:  1973-11       Impact factor: 9.410

3.  Electrical field distribution in the human body.

Authors:  S K Guha; M R Khan; S N Tandon
Journal:  Phys Med Biol       Date:  1973-09       Impact factor: 3.609

4.  Pathogenesis of pulmonary edema following head trauma. An experimental study.

Authors:  R L Simmons; T B Ducker; R W Anderson
Journal:  J Trauma       Date:  1968-09

5.  Increased intracranial pressure and pulmonary edema. 1. Clinical study of 11 patients.

Authors:  T B Ducker
Journal:  J Neurosurg       Date:  1968-02       Impact factor: 5.115

6.  The hazard of interstitial pulmonary edema.

Authors:  E D Frank
Journal:  Ann Surg       Date:  1969-04       Impact factor: 12.969

7.  Transthoracic electrical impedance for the early detection of pulmonary edema.

Authors:  M Pomerantz; R Baumgartner; J Lauridson; B Eiseman
Journal:  Surgery       Date:  1969-07       Impact factor: 3.982

8.  Effect of frusemide on pulmonary blood volume.

Authors:  M L Bhatia; I Singh; S C Manchanda; P K Khanna; S B Roy
Journal:  Br Med J       Date:  1969-05-31

9.  Transthoracic electrical impedance s a guide to intravascular overload.

Authors:  I R Berman; W L Scheetz; E B Jenkins; H V Hufnagel
Journal:  Arch Surg       Date:  1971-01

10.  The specific resistance of biological material--a compendium of data for the biomedical engineer and physiologist.

Authors:  L A Geddes; L E Baker
Journal:  Med Biol Eng       Date:  1967-05
View more
  5 in total

1.  Stroke volume equation for impedance cardiography.

Authors:  D P Bernstein; H J M Lemmens
Journal:  Med Biol Eng Comput       Date:  2005-07       Impact factor: 2.602

2.  Microprocessor-based system for measurement of electrical impedances during haemodialysis and in postoperative care.

Authors:  H G Goovaerts; F R de Vries; J H Meijer; P M de Vries; A J Donker; H Schneider
Journal:  Med Biol Eng Comput       Date:  1988-01       Impact factor: 2.602

3.  Body volume changes during simulated microgravity: auditory changes, segmental fluid redistribution, and regional hemodynamics.

Authors:  L D Montgomery; A J Parmet; C R Booher
Journal:  Ann Biomed Eng       Date:  1993 Jul-Aug       Impact factor: 3.934

4.  Hemodynamic response to exercise as measured by the solar IKG impedance cardiography module and correlation with metabolic variables.

Authors:  Stephan Ziegeler; Ulrich Grundmann; Oliver Fuerst; Alexander Raddatz; Sascha Kreuer
Journal:  J Clin Monit Comput       Date:  2006-11-04       Impact factor: 1.977

5.  Prototype development of an electrical impedance based simultaneous respiratory and cardiac monitoring system for gated radiotherapy.

Authors:  Kirpal Kohli; Jeff Liu; Devin Schellenberg; Anand Karvat; Ash Parameswaran; Parvind Grewal; Steven Thomas
Journal:  Biomed Eng Online       Date:  2014-10-14       Impact factor: 2.819

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.