Small photon beam measurements using radiochromic film and Monte Carlo simulations in a water phantom.

Olivia A García-Garduño1, José M Lárraga-Gutiérrez, Mercedes Rodríguez-Villafuerte, Arnulfo Martínez-Dávalos, Miguel A Celis.   

Abstract

This work reports the use of both GafChromic EBT film immersed in a water phantom and Monte Carlo (MC) simulations for small photon beam stereotactic radiosurgery dosimetry. Circularly collimated photon beams with diameters in the 4-20 mm range of a dedicated 6 MV linear accelerator (Novalis, BrainLAB, Germany) were used to perform off-axis ratios, tissue maximum ratios and total scatter factors measurements, and MC simulations. GafChromic EBT film data show an excellent agreement with MC results (<2.7%) for all measured quantities. Copyright 2010 Elsevier Ireland Ltd. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20378193     DOI: 10.1016/j.radonc.2010.03.016

Source DB:  PubMed          Journal:  Radiother Oncol        ISSN: 0167-8140            Impact factor:   6.280


  9 in total

1.  Investigating the Electronic Portal Imaging Device for Small Radiation Field Measurements.

Authors:  Arpita Agarwal; Nikhil Rastogi; K J Maria Das; S A Yoganathan; D Udayakumar; Shaleen Kumar
Journal:  J Med Phys       Date:  2017 Apr-Jun

2.  Small fields measurements with radiochromic films.

Authors:  Antonio Gonzalez-Lopez; Juan-Antonio Vera-Sanchez; Jose-Domingo Lago-Martin
Journal:  J Med Phys       Date:  2015 Apr-Jun

3.  A novel method for the determination of field output factors and output correction factors for small static fields for six diodes and a microdiamond detector in megavoltage photon beams.

Authors:  Božidar Casar; Eduard Gershkevitsh; Ignasi Mendez; Slaven Jurković; M Saiful Huq
Journal:  Med Phys       Date:  2018-12-24       Impact factor: 4.071

4.  Detectors assessment for stereotactic radiosurgery with cones.

Authors:  Nicolas Garnier; Régis Amblard; Rémy Villeneuve; Rodolphe Haykal; Cécile Ortholan; Philippe Colin; Anaïs Gérard; Sarah Belhomme; Franck Mady; Mourad Benabdesselam; Benjamin Serrano
Journal:  J Appl Clin Med Phys       Date:  2018-09-14       Impact factor: 2.102

5.  A multi-center output factor intercomparison to uncover systematic inaccuracies in small field dosimetry.

Authors:  Stefania Clemente; Laura Masi; Christian Fiandra; Elisabetta Cagni; Elena Villaggi; Marco Esposito; Francesca Romana Giglioli; Carmelo Marino; Lidia Strigari; Cristina Garibaldi; Michele Stasi; Pietro Mancosu; Serenella Russo
Journal:  Phys Imaging Radiat Oncol       Date:  2018-03-26

6.  Radiosurgical third ventriculostomy: Technical note.

Authors:  Guillermo Axayacalt Gutiérrez-Aceves; Sergio Moreno-Jiménez; Miguel Ángel Celis; Mariana Hernández-Bojórquez
Journal:  Surg Neurol Int       Date:  2012-10-13

7.  Detector-specific correction factors in radiosurgery beams and their impact on dose distribution calculations.

Authors:  Olivia A García-Garduño; Manuel A Rodríguez-Ávila; José M Lárraga-Gutiérrez
Journal:  PLoS One       Date:  2018-05-15       Impact factor: 3.240

8.  Different Dosimeters/Detectors Used in Small-Field Dosimetry: Pros and Cons.

Authors:  Wrya Parwaie; Soheila Refahi; Mahdieh Afkhami Ardekani; Bagher Farhood
Journal:  J Med Signals Sens       Date:  2018 Jul-Sep

9.  Output correction factors for small static fields in megavoltage photon beams for seven ionization chambers in two orientations - perpendicular and parallel.

Authors:  Božidar Casar; Eduard Gershkevitsh; Ignasi Mendez; Slaven Jurković; M Saiful Huq
Journal:  Med Phys       Date:  2019-11-25       Impact factor: 4.071

  9 in total