Literature DB >> 20377658

Continuous glucose monitoring.

B W Bode1, T Battelino.   

Abstract

Real-time continuous glucose monitoring (RT-CGM) has the potential to revolutionise the care and treatment of individuals with type 1 diabetes (T1D). During the past three years, several devices to measure the interstitial fluid intermittently or continuously have been developed and approved as an adjunct to blood glucose monitoring for use in individuals with T1D. Original studies using these earlier devices showed promise in lowering HbA1c in selected individuals with suboptimal control (1). The first randomised controlled trial with a subcutaneous continuous sensor demonstrated a significant decrease in HbA1c in adult and paediatric patients with poor metabolic control using the RT-CGM device continuously for 3 months compared with the self-monitoring of blood glucose (SMBG) control group (2). Recent randomised controlled trials clearly demonstrated that RT-CGM can significantly reduce HbA1c. Additionally, retrospective use of CGM data can positively affect metabolic control in both type 1 and type 2 diabetes.

Entities:  

Mesh:

Year:  2010        PMID: 20377658     DOI: 10.1111/j.1742-1241.2009.02272.x

Source DB:  PubMed          Journal:  Int J Clin Pract Suppl        ISSN: 1368-504X


  10 in total

1.  Non-invasive continuous glucose monitoring: improved accuracy of point and trend estimates of the Multisensor system.

Authors:  Mattia Zanon; Giovanni Sparacino; Andrea Facchinetti; Michela Riz; Mark S Talary; Roland E Suri; Andreas Caduff; Claudio Cobelli
Journal:  Med Biol Eng Comput       Date:  2012-06-22       Impact factor: 2.602

2.  Are Systematic Reviews and Meta-Analyses Appropriate Tools for Assessing Evolving Medical Device Technologies?

Authors:  David Price; Claudia Graham; Christopher G Parkin; Thomas A Peyser
Journal:  J Diabetes Sci Technol       Date:  2015-09-29

3.  Tissue Response to Subcutaneous Infusion Catheter.

Authors:  Ershuai Zhang; Zhiqiang Cao
Journal:  J Diabetes Sci Technol       Date:  2019-03-31

4.  Nocturnal hypoglycemia identified by a continuous glucose monitoring system in patients with primary adrenal insufficiency (Addison's Disease).

Authors:  Gesine Meyer; Annika Hackemann; Juergen Reusch; Klaus Badenhoop
Journal:  Diabetes Technol Ther       Date:  2012-01-13       Impact factor: 6.118

5.  Foreign Body Reaction to a Subcutaneously Implanted Self-Cleaning, Thermoresponsive Hydrogel Membrane for Glucose Biosensors.

Authors:  Alexander A Abraham; A Kristen Means; Fred J Clubb; Ruochong Fei; Andrea K Locke; Erica G Gacasan; Gerard L Coté; Melissa A Grunlan
Journal:  ACS Biomater Sci Eng       Date:  2018-10-09

6.  High Affinity Mannotetraose as an Alternative to Dextran in ConA Based Fluorescent Affinity Glucose Assay Due to Improved FRET Efficiency.

Authors:  Andrea K Locke; Brian M Cummins; Gerard L Coté
Journal:  ACS Sens       Date:  2016-03-16       Impact factor: 7.711

7.  Effects of pH, lactate, hematocrit and potassium level on the accuracy of continuous glucose monitoring (CGM) in pediatric intensive care unit.

Authors:  Gábor Marics; Levente Koncz; Katalin Eitler; Barbara Vatai; Boglárka Szénási; David Zakariás; Borbála Mikos; Anna Körner; Péter Tóth-Heyn
Journal:  Ital J Pediatr       Date:  2015-03-19       Impact factor: 2.638

8.  A Personalized Healthcare Monitoring System for Diabetic Patients by Utilizing BLE-Based Sensors and Real-Time Data Processing.

Authors:  Ganjar Alfian; Muhammad Syafrudin; Muhammad Fazal Ijaz; M Alex Syaekhoni; Norma Latif Fitriyani; Jongtae Rhee
Journal:  Sensors (Basel)       Date:  2018-07-06       Impact factor: 3.576

9.  A Layer-by-Layer Approach To Retain a Fluorescent Glucose Sensing Assay within the Cavity of a Hydrogel Membrane.

Authors:  Andrea K Locke; Anna Kristen Means; Ping Dong; Tyler J Nichols; Gerard L Coté; Melissa A Grunlan
Journal:  ACS Appl Bio Mater       Date:  2018-10-10

Review 10.  Italian contributions to the development of continuous glucose monitoring sensors for diabetes management.

Authors:  Giovanni Sparacino; Mattia Zanon; Andrea Facchinetti; Chiara Zecchin; Alberto Maran; Claudio Cobelli
Journal:  Sensors (Basel)       Date:  2012-10-12       Impact factor: 3.576

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.