Literature DB >> 20369103

Intracerebral penetration of a zygomatic dental implant and consequent therapeutic dilemmas: case report.

Hervé Reychler1, Raphael Olszewski.   

Abstract

This case report describes a unique intracerebral penetration of a zygomatic implant inserted in the pterygoid region. A 47-year-old female patient developed severe persistent headaches immediately after two zygomatic and two standard implants were inserted under general anesthesia. However, no additional treatment or radiologic assessment was performed at that time by the treating surgeon. The maxilla was rehabilitated with an implant-supported fixed denture 3 months after the implants were placed. An episode of acute left maxillary sinusitis occurred shortly after insertion of the fixed denture. Treatment with antibiotics was insufficient, and the patient developed chronic left maxillary sinusitis. The patient presented herself to a neurologist with symptoms of chronic fatigue and severe headaches. Cerebral magnetic resonance imaging demonstrated the intracerebral penetration of a foreign body that resembled a dental implant. The authors sought to resolve the intracerebral penetration of the foreign body, along with the persistent maxillary chronic sinusitis with its concomitant risk of ascending cerebral infection. Computer-assisted preoperative planning associated with computer-assisted three-dimensional transfer should be used to avoid such a dangerous complication. Postoperative computed tomography assessment should be performed after zygomatic implant surgery. Finally, any neurologic impairment of the patient after pterygoid implantation should also be treated immediately.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20369103

Source DB:  PubMed          Journal:  Int J Oral Maxillofac Implants        ISSN: 0882-2786            Impact factor:   2.804


  9 in total

Review 1.  Survival and complications of zygomatic implants: a systematic review.

Authors:  Bruno Ramos Chrcanovic; Mauro Henrique Nogueira Guimarães Abreu
Journal:  Oral Maxillofac Surg       Date:  2012-05-06

2.  Comparison of pre-bent titanium mesh versus polyethylene implants in patient specific orbital reconstructions.

Authors:  Marcin Kozakiewicz; Piotr Szymor
Journal:  Head Face Med       Date:  2013-10-29       Impact factor: 2.151

3.  Evaluation of satisfaction of individuals rehabilitated with zygomatic implants as regards anesthetic and sedative procedure: A prospective cohort study.

Authors:  Paulo H T Almeida; Alexander D'Alvia Salvoni; Fabiana M G França
Journal:  Ann Med Surg (Lond)       Date:  2017-09-01

4.  Three-Dimensional Evaluation of Maxillary Sinus Septa for Implant Placement.

Authors:  Eliza Dragan; Guillaume A Odri; Gabriel Melian; Danisia Haba; Raphael Olszewski
Journal:  Med Sci Monit       Date:  2017-03-21

5.  Zygomatic implant penetration to the central portion of orbit: a case report.

Authors:  Luan Mavriqi; Felice Lorusso; Roberto Conte; Biagio Rapone; Antonio Scarano
Journal:  BMC Ophthalmol       Date:  2021-03-06       Impact factor: 2.209

6.  Informed Consent from a Historical, Societal, Ethical, Legal, and Practical Perspective.

Authors:  Lee M Jameson; Sandra K Al-Tarawneh
Journal:  J Prosthodont       Date:  2022-03-08       Impact factor: 3.485

7.  Three-Dimensional Evaluation of Implant Positioning in the Maxillary Sinus Septum: A Retrospective Study.

Authors:  Eliza Dragan; Odri A Guillaume; Danisia Haba; Raphael Olszewski
Journal:  Med Sci Monit       Date:  2015-09-08

8.  Intraorbital hemorrhage following a secondary intervention at integrated zygomatic implants: A case report.

Authors:  Philippe Van Camp; Luc Vrielinck; Bert Gemels; Constantinus Politis
Journal:  Int J Surg Case Rep       Date:  2018-02-04

9.  Reliability and accuracy of dynamic navigation for zygomatic implant placement.

Authors:  Yiqun Wu; Baoxin Tao; Kengliang Lan; Yihan Shen; Wei Huang; Feng Wang
Journal:  Clin Oral Implants Res       Date:  2022-02-15       Impact factor: 5.021

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.