Literature DB >> 20367372

Biomechanics of a lumbar interspinous anchor with anterior lumbar interbody fusion.

Dean G Karahalios1, Taro Kaibara, Randall W Porter, Udaya K Kakarla, Phillip M Reyes, Ali A Baaj, Ali S Yaqoobi, Neil R Crawford.   

Abstract

OBJECT: An interspinous anchor (ISA) provides fixation to the lumbar spine to facilitate fusion. The biomechanical stability provided by the Aspen ISA was studied in applications utilizing an anterior lumbar interbody fusion (ALIF) construct.
METHODS: Seven human cadaveric L3-S1 specimens were tested in the following states: 1) intact; 2) after placing an ISA at L4-5; 3) after ALIF with an ISA; 4) after ALIF with an ISA and anterior screw/plate fixation system; 5) after removing the ISA (ALIF with plate only); 6) after removing the plate (ALIF only); and 7) after applying bilateral pedicle screws and rods. Pure moments (7.5 Nm maximum) were applied in flexion and extension, lateral bending, and axial rotation while recording angular motion optoelectronically. Changes in angulation as well as foraminal height were also measured.
RESULTS: All instrumentation variances except ALIF alone reduced angular range of motion (ROM) significantly from normal in all directions of loading. The ISA was most effective in limiting flexion and extension (25% of normal) and less effective in reducing lateral bending (71% of normal) and axial rotation (71% of normal). Overall, ALIF with an ISA provided stability that was statistically equivalent to ALIF with bilateral pedicle screws and rods. An ISA-augmented ALIF allowed less ROM than plate-augmented ALIF during flexion, extension, and lateral bending. Use of the ISA resulted in flexion at the index level, with a resultant increase in foraminal height. Compensatory extension at the adjacent levels prevented any significant change in overall sagittal balance.
CONCLUSIONS: When used with ALIF at L4-5, the ISA provides immediate rigid immobilization of the lumbar spine, allowing equivalent ROM to that of a pedicle screw/rod system, and smaller ROM than an anterior plate. When used with ALIF, the ISA may offer an alternative to anterior plate fixation or bilateral pedicle screw/rod constructs.

Entities:  

Mesh:

Year:  2010        PMID: 20367372     DOI: 10.3171/2009.10.SPINE09305

Source DB:  PubMed          Journal:  J Neurosurg Spine        ISSN: 1547-5646


  18 in total

1.  Biomechanical analysis of lumbar interbody fusion supplemented with various posterior stabilization systems.

Authors:  Wei Fan; Li-Xin Guo; Ming Zhang
Journal:  Eur Spine J       Date:  2021-05-04       Impact factor: 3.134

2.  Interspinous posterior devices: What is the real surgical indication?

Authors:  Alessandro Landi
Journal:  World J Clin Cases       Date:  2014-09-16       Impact factor: 1.337

Review 3.  Foraminal height measurement techniques.

Authors:  Kevin Phan; Ralph J Mobbs; Prashanth J Rao
Journal:  J Spine Surg       Date:  2015-12

4.  Biomechanical analysis of a new lumbar interspinous device with optimized topology.

Authors:  Chen-Sheng Chen; Shih-Liang Shih
Journal:  Med Biol Eng Comput       Date:  2018-01-06       Impact factor: 2.602

5.  Anterior and Lateral Lumbar Interbody Fusion With Supplemental Interspinous Process Fixation: Outcomes from a Multicenter, Prospective, Randomized, Controlled Study.

Authors:  Ripul Panchal; Ryan Denhaese; Clint Hill; K Brandon Strenge; Alexandre DE Moura; Peter Passias; Paul Arnold; Andrew Cappuccino; M David Dennis; Andy Kranenburg; Brieta Ventimiglia; Kim Martin; Chris Ferry; Sarah Martineck; Camille Moore; Kee Kim
Journal:  Int J Spine Surg       Date:  2018-08-03

6.  Biomechanics of disc degeneration.

Authors:  V Palepu; M Kodigudla; V K Goel
Journal:  Adv Orthop       Date:  2012-06-17

7.  The current testing protocols for biomechanical evaluation of lumbar spinal implants in laboratory setting: a review of the literature.

Authors:  Sabrina A Gonzalez-Blohm; James J Doulgeris; William E Lee; Thomas M Shea; Kamran Aghayev; Frank D Vrionis
Journal:  Biomed Res Int       Date:  2015-02-15       Impact factor: 3.411

8.  Clinical outcomes of a polyaxial interspinous fusion system.

Authors:  Joseph A Sclafani; Kevin Liang; Donna D Ohnmeiss; Charles Gordon
Journal:  Int J Spine Surg       Date:  2014-12-01

9.  Biomechanical characteristics of an integrated lumbar interbody fusion device.

Authors:  Leonard I Voronov; Georgios Vastardis; Julia Zelenakova; Gerard Carandang; Robert M Havey; Erik I Waldorff; Michael R Zindrick; Avinash G Patwardhan
Journal:  Int J Spine Surg       Date:  2014-12-01

10.  Posterior interspinous fusion device for one-level fusion in degenerative lumbar spine disease : comparison with pedicle screw fixation - preliminary report of at least one year follow up.

Authors:  Ho Jung Kim; Koang Hum Bak; Hyoung Joon Chun; Suck Jun Oh; Tae Hoon Kang; Moon Sool Yang
Journal:  J Korean Neurosurg Soc       Date:  2012-10-22
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.