Percutaneous screw fixation of acetabular fractures with 2D fluoroscopy-based computerized navigation.

Gao Hong1, Luo Cong-Feng, Hu Cheng-Fang, Zhang Chang-Qing, Zeng Bing-Fang.   

Abstract

INTRODUCTION: The treatment of displaced acetabular fractures with formal open reduction and internal fixation has gained general acceptance. However, extensile exposure can lead to complications. Two-dimensional fluoroscopy-based computerized navigation for placement of percutaneous screw across non-displaced acetabular fractures has attracted interest by making use of stored patient-specific imaging data to provide real-time guidance in multiple image planes during implant placement. The purpose of the present study was to document early treatment results and complications associated with this new technique and evaluate its clinical application to displaced acetabular fractures amenable to closed or limited open reduction.
MATERIALS AND METHODS: Eighteen adult patients with 12 non-displaced and 8 displaced acetabular fractures were treated with percutaneous screw fixation under the guidance of a fluoroscopy-based navigation system. There were 14 men and four women with a mean age of 42.1 years (range 19-54 years). According to the AO and Orthopaedic Trauma Association Classification, there were nine 62-A3, five 62-B1, three 62-B2, and three 62-B3. The mean follow-up was 21 months (range 12-28 months). The mean time from injury to surgery was 4 days (range 2-7 days).
RESULTS: A total of 30 acetabular screws were inserted, including 21 anterior column screws and 9 posterior column screws. The average operation time was 24.6 min (range 16-47 min) from the image acquisition to wound closure. The average fluoroscopic time was 28.4 s (range 11-58 s). Compared to the final position of the screw, the average deviated distance of wire tip was 2.5 mm (range 1.1-3.6 mm) and the average trajectory difference was 2.45 degrees (range 1.5 degrees -4.6 degrees ). Maximal gap displacement averaged 10 mm (range 2-22 mm) preoperatively and 3 mm (range 0-5 mm) postoperatively; while maximal step displacement averaged 4 mm (range 1-10 mm) preoperatively and 2 mm (range 0-4 mm) postoperatively. One patient sustained a transient femoral nerve palsy and resolved 2 months after the operation. No superficial or deep infection occurred. Using the rating system of D'Aubigne and Postel, 13 patients had excellent results, 4 patients had good results, and 1 patient had a fair result.
CONCLUSION: Percutaneous screw fixation of acetabular fractures with 2D fluoroscopy-based navigation could be applied not only to non-displaced fractures but also to displaced fractures amenable to closed or limited open reduction.

Entities:  

Mesh:

Year:  2010        PMID: 20364263     DOI: 10.1007/s00402-010-1095-2

Source DB:  PubMed          Journal:  Arch Orthop Trauma Surg        ISSN: 0936-8051            Impact factor:   3.067


  13 in total

1.  Computer-Assisted Orthopedic and Trauma Surgery.

Authors:  Timo Stübig; Henning Windhagen; Christian Krettek; Max Ettinger
Journal:  Dtsch Arztebl Int       Date:  2020-11-20       Impact factor: 5.594

2.  [Intraoperative virtual implant planning for volar plate osteosynthesis of distal radius fractures].

Authors:  J Franke; S Y Vetter; K Reising; S Herrmann; N P Südkamp; P A Grützner; J von Recum
Journal:  Unfallchirurg       Date:  2016-01       Impact factor: 1.000

3.  A novel navigation template for fixation of acetabular posterior column fractures with antegrade lag screws: design and application.

Authors:  Hongfen Chen; Gang Wang; Runguang Li; Yongjian Sun; Fuming Wang; Hui Zhao; Peijun Zhang; Xuanxuan Zhang
Journal:  Int Orthop       Date:  2015-06-27       Impact factor: 3.075

4.  Gun barrel view of the anterior pelvic ring for percutaneous anterior column or superior pubic ramus screw placement.

Authors:  Nicholas Quercetti; Brandon Horne; Zac DiPaolo; Michael J Prayson
Journal:  Eur J Orthop Surg Traumatol       Date:  2016-10-07

5.  Screw placement in percutaneous acetabular surgery: gender differences of anatomical landmarks in a cadaveric study.

Authors:  Thomas Dienstknecht; Michael Müller; Richard Sellei; Michael Nerlich; Franz Josef Müller; Bernd Fuechtmeier; Arne Berner
Journal:  Int Orthop       Date:  2012-12-19       Impact factor: 3.075

6.  Anatomical study of anterior column screw tunnels through virtual three-dimensional models of the pelvis.

Authors:  Hua Chen; Peifu Tang; Yimin Yao; Fei She; Yan Wang
Journal:  Eur J Orthop Surg Traumatol       Date:  2014-01-11

7.  Influence of multi-angle input of intraoperative fluoroscopic images on the spatial positioning accuracy of the C-arm calibration-based algorithm of a CAOS system.

Authors:  Xiangqian Chen; Yu Wang; Gang Zhu; Weijun Zhang; Gang Zhou; Yubo Fan
Journal:  Med Biol Eng Comput       Date:  2020-01-09       Impact factor: 2.602

8.  Co-localized augmented human and X-ray observers in collaborative surgical ecosystem.

Authors:  Javad Fotouhi; Mathias Unberath; Tianyu Song; Jonas Hajek; Sing Chun Lee; Bastian Bier; Andreas Maier; Greg Osgood; Mehran Armand; Nassir Navab
Journal:  Int J Comput Assist Radiol Surg       Date:  2019-07-26       Impact factor: 2.924

9.  Minimally invasive surgery under fluoro-navigation for anterior pelvic ring fractures.

Authors:  Kai-Hua Zhou; Cong-Feng Luo; Nong Chen; Cheng-Fang Hu; Fu-Gen Pan
Journal:  Indian J Orthop       Date:  2016 May-Jun       Impact factor: 1.251

10.  Comparison of Isocentric C-Arm 3-Dimensional Navigation and Conventional Fluoroscopy for Percutaneous Retrograde Screwing for Anterior Column Fracture of Acetabulum: An Observational Study.

Authors:  Jiliang He; Guoqing Tan; Dongsheng Zhou; Liang Sun; Qinghu Li; Yongliang Yang; Ping Liu
Journal:  Medicine (Baltimore)       Date:  2016-01       Impact factor: 1.817

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.