Literature DB >> 20363765

The fate of incomplete stent apposition with drug-eluting stents: an optical coherence tomography-based natural history study.

Yukio Ozaki1, Masanori Okumura, Tevfik F Ismail, Hiroyuki Naruse, Kousuke Hattori, Shino Kan, Makoto Ishikawa, Tomoko Kawai, Yasushi Takagi, Junichi Ishii, Francesco Prati, Patrick W Serruys.   

Abstract

AIMS: To assess the fate of incomplete stent apposition (ISA) after deployment of sirolimus-eluting stents (SESs). METHODS AND
RESULTS: Thirty-two patients having intravascular ultrasound (IVUS)-guided PCI with SESs underwent assessment of stent deployment with quantitative coronary angiography, IVUS, and optical coherence tomography (OCT) pre-procedure, post-procedure, and at 10 months follow-up. Incomplete stent apposition was defined as separation of a stent strut from the inner vessel wall by >160 microm. At follow-up, 4.67% of struts with ISA at deployment failed to heal and 7.59% which were well apposed did not develop neointimal hyperplasia even after 10 months. Lesion remodelling was responsible for the development of late ISA in only 0.37% of struts. Failure of adequate neointimal hyperplasia was quantitatively the most important mechanism responsible for persistent acute ISA, classified in previous studies, which relied only on follow-up OCT, as late ISA. Thrombus was visualized in 20.6% of struts with ISA at follow-up and in 2.0% of struts with a good apposition (P < 0.001).
CONCLUSION: In patients with SESs, ISA can fail to heal and even complete apposition can be associated with no neointimal hyperplasia. Incomplete stent apposition without neointimal hyperplasia was significantly associated with the presence of OCT-detected thrombus at follow-up, and may constitute a potent substrate for late stent thrombosis.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20363765     DOI: 10.1093/eurheartj/ehq066

Source DB:  PubMed          Journal:  Eur Heart J        ISSN: 0195-668X            Impact factor:   29.983


  32 in total

1.  Optical coherence tomography-based evaluation of malapposed strut coverage after drug-eluting stent implantation.

Authors:  Byeong-Keuk Kim; Dong-Ho Shin; Jung-Sun Kim; Young-Guk Ko; Donghoon Choi; Yangsoo Jang; Myeong-Ki Hong
Journal:  Int J Cardiovasc Imaging       Date:  2012-03-25       Impact factor: 2.357

2.  Wall Apposition Is a Key Factor for Aneurysm Occlusion after Flow Diversion: A Histologic Evaluation in 41 Rabbits.

Authors:  A Rouchaud; C Ramana; W Brinjikji; Y-H Ding; D Dai; T Gunderson; J Cebral; D F Kallmes; R Kadirvel
Journal:  AJNR Am J Neuroradiol       Date:  2016-07-07       Impact factor: 3.825

3.  New strategies in the treatment of coronary bifurcations.

Authors:  I Iakovou; N Foin; A Andreou; N Viceconte; C Di Mario
Journal:  Herz       Date:  2011-05       Impact factor: 1.443

Review 4.  Causes, assessment, and treatment of stent thrombosis--intravascular imaging insights.

Authors:  Daniel S Ong; Ik-Kyung Jang
Journal:  Nat Rev Cardiol       Date:  2015-03-17       Impact factor: 32.419

5.  Effects of endothelium, stent design and deployment on the nitric oxide transport in stented artery: a potential role in stent restenosis and thrombosis.

Authors:  Xiao Liu; Min Wang; Nan Zhang; Zhanming Fan; Yubo Fan; Xiaoyan Deng
Journal:  Med Biol Eng Comput       Date:  2015-02-26       Impact factor: 2.602

6.  Cut-off value of mal-apposition volume and depth for resolution at early phase of acute incomplete stent apposition after CoCr-EES implantation.

Authors:  Yohei Uchimura; Tomonori Itoh; Hideto Oda; Yuya Taguchi; Wataru Sasaki; Kyosuke Kaneko; Tsubasa Sakamoto; Iwao Goto; Masafumi Sakuma; Masaru Ishida; Tatsuo Kikuchi; Daisuke Terashita; Hiromasa Otake; Yoshihiro Morino; Toshiro Shinke
Journal:  Int J Cardiovasc Imaging       Date:  2019-06-29       Impact factor: 2.357

7.  Unrestricted utilization of frequency domain optical coherence tomography in coronary interventions.

Authors:  Gregory T Stefano; Hiram G Bezerra; Emile Mehanna; Hirosada Yamamoto; Yusuke Fujino; Wei Wang; Guilherme Attizzani; Daniel Chamié; Daniel I Simon; Marco A Costa
Journal:  Int J Cardiovasc Imaging       Date:  2012-10-12       Impact factor: 2.357

8.  Invasive Imaging of Bioresorbable Coronary Scaffolds - A Review.

Authors:  Nienke S van Ditzhuijzen; Jurgen Mr Ligthart; Nico Bruining; Evelyn Regar; Heleen Mm van Beusekom
Journal:  Interv Cardiol       Date:  2013-03

9.  Erosion/malapposition of a sirolimus eluting stent - optical coherence tomography image - a case report.

Authors:  G Sengottuvelu
Journal:  Indian Heart J       Date:  2012-11-27

10.  Impact of strut-vessel distance and underlying plaque type on the resolution of acute strut malapposition: serial optimal coherence tomography analysis after everolimus-eluting stent implantation.

Authors:  Takumi Inoue; Toshiro Shinke; Hiromasa Otake; Masayuki Nakagawa; Hirotoshi Hariki; Tsuyoshi Osue; Masamichi Iwasaki; Yu Taniguchi; Ryo Nishio; Noritoshi Hiranuma; Akihide Konishi; Hiroto Kinutani; Masaru Kuroda; Ken-ichi Hirata
Journal:  Int J Cardiovasc Imaging       Date:  2014-04-19       Impact factor: 2.357

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.