Preliminary studies for a CBCT imaging protocol for offline organ motion analysis: registration software validation and CTDI measurements.

Maria Daniela Falco1, Davide Fontanarosa, Roberto Miceli, Alessandra Carosi, Riccardo Santoni, Marco D'Andrea.   

Abstract

Cone-beam X-ray volumetric imaging in the treatment room, allows online correction of set-up errors and offline assessment of residual set-up errors and organ motion. In this study the registration algorithm of the X-ray volume imaging software (XVI, Elekta, Crawley, United Kingdom), which manages a commercial cone-beam computed tomography (CBCT)-based positioning system, has been tested using a homemade and an anthropomorphic phantom to: (1) assess its performance in detecting known translational and rotational set-up errors and (2) transfer the transformation matrix of its registrations into a commercial treatment planning system (TPS) for offline organ motion analysis. Furthermore, CBCT dose index has been measured for a particular site (prostate: 120 kV, 1028.8 mAs, approximately 640 frames) using a standard Perspex cylindrical body phantom (diameter 32 cm, length 15 cm) and a 10-cm-long pencil ionization chamber. We have found that known displacements were correctly calculated by the registration software to within 1.3 mm and 0.4°. For the anthropomorphic phantom, only translational displacements have been considered. Both studies have shown errors within the intrinsic uncertainty of our system for translational displacements (estimated as 0.87 mm) and rotational displacements (estimated as 0.22°). The resulting table translations proposed by the system to correct the displacements were also checked with portal images and found to place the isocenter of the plan on the linac isocenter within an error of 1 mm, which is the dimension of the spherical lead marker inserted at the center of the homemade phantom. The registration matrix translated into the TPS image fusion module correctly reproduced the alignment between planning CT scans and CBCT scans. Finally, measurements on the CBCT dose index indicate that CBCT acquisition delivers less dose than conventional CT scans and electronic portal imaging device portals. The registration software was found to be accurate, and its registration matrix can be easily translated into the TPS and a low dose is delivered to the patient during image acquisition. These results can help in designing imaging protocols for offline evaluations.
Copyright © 2011 American Association of Medical Dosimetrists. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2010        PMID: 20363613     DOI: 10.1016/j.meddos.2010.01.003

Source DB:  PubMed          Journal:  Med Dosim        ISSN: 1873-4022            Impact factor:   1.482


  4 in total

1.  Preliminary experience of a predictive model to define rectal volume and rectal dose during the treatment of prostate cancer.

Authors:  M D Falco; M D'Andrea; D Fedele; R Barbarino; M Benassi; E Giudice; E Hamoud; G Ingrosso; P Ladogana; F Santarelli; G Tortorelli; R Santoni
Journal:  Br J Radiol       Date:  2011-09       Impact factor: 3.039

2.  Is the in vivo dosimetry with the OneDosePlusTM system able to detect intra-fraction motion? A retrospective analysis of in vivo data from breast and prostate patients.

Authors:  Maria Daniela Falco; Marco D'Andrea; Alessia Lo Bosco; Mauro Rebuzzi; Elisabetta Ponti; Barbara Tolu; Grazia Tortorelli; Rosaria Barbarino; Luana Di Murro; Riccardo Santoni
Journal:  Radiat Oncol       Date:  2012-06-20       Impact factor: 3.481

3.  Cone-beam computed tomography in hypofractionated stereotactic radiotherapy for brain metastases.

Authors:  Gianluca Ingrosso; Roberto Miceli; Dahlia Fedele; Elisabetta Ponti; Michaela Benassi; Rosaria Barbarino; Luana Di Murro; Emilia Giudice; Federico Santarelli; Riccardo Santoni
Journal:  Radiat Oncol       Date:  2012-04-01       Impact factor: 3.481

4.  Automated replication of cone beam CT-guided treatments in the Pinnacle(3) treatment planning system for adaptive radiotherapy.

Authors:  Catriona Hargrave; Nicole Mason; Robyn Guidi; Julie-Anne Miller; Jillian Becker; Matthew Moores; Kerrie Mengersen; Michael Poulsen; Fiona Harden
Journal:  J Med Radiat Sci       Date:  2015-10-03
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.