Literature DB >> 20362766

Accuracy of the newly formulated vinyl siloxanether elastomeric impression material.

Thomas Stober1, Glen H Johnson, Marc Schmitter.   

Abstract

STATEMENT OF PROBLEM: A newly formulated vinyl siloxanether elastomeric impression material is available, but there is little knowledge of its accuracy in relation to existing materials.
PURPOSE: The purpose of this in vitro study was to assess the accuracy of disinfected vinyl siloxanether impressions and compare the accuracy to a common vinyl polysiloxane and a polyether impression system.
MATERIAL AND METHODS: Impressions were made from a modified dentoform master model containing a simulated crown preparation. Dimensional changes (mm) between the master model and working casts (type IV gypsum) were assessed. The following were evaluated: vinyl polysiloxane in a 1-step, dual-viscosity technique (VPS Dual), polyether as monophase material (PE Mono), and vinyl siloxanether in a 1-step, dual-viscosity (VSE Dual), and monophase technique (VSE Mono). Measurements of the master model and working casts, including anteroposterior (AP) and cross-arch (XA) dimensions, were made with a measuring microscope. The simulated crown preparation was measured in mesiodistal (MDG, MDO), buccolingual (BLG, BLO), and occlusogingival dimensions (OGL, OGB). Disinfection involved immersion for 10 minutes in potassium peroxomonosulfate, sodium benzoate, tartaric acid solution, or no disinfection (control) (n=8). A multivariate GLM statistical approach (MANOVA) was used to analyze the data (alpha=.05). Pearson's correlation test was used for related dimensions.
RESULTS: The AP and XA dimensions of working casts were larger than the master for the disinfected condition and control. Whether disinfected or not, the working dies were shorter in height (OGB, OGL), larger in the buccolingual dimension (BLO, BLG), somewhat larger in the MDO dimension, and somewhat smaller in the MDG dimension compared to the prepared tooth of the master model, resulting in an irregular or oval profile. There were significant differences among the impression systems for each dimension except AP. Differences between the disinfected and nondisinfected conditions were significant (P=.03) with respect to dimensions of the gypsum working cast, but not for dimensions of the working die (P=.97). In general, differences relative to the master were small and of minor clinical significance considering marginal gaps of crowns smaller than 150-100 mum are considered clinically acceptable.
CONCLUSIONS: VSE monophase impressions and VSE dual-viscosity impressions demonstrated acceptable accuracy for clinical use with immersion disinfection, since the results for VSE were comparable to the results for PE and VPS materials, and the differences as compared to the master model were small. Copyright 2010 The Editorial Council of the Journal of Prosthetic Dentistry. Published by Mosby, Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20362766     DOI: 10.1016/S0022-3913(10)60035-2

Source DB:  PubMed          Journal:  J Prosthet Dent        ISSN: 0022-3913            Impact factor:   3.426


  17 in total

1.  Evaluation of dimensional stability and accuracy of autoclavable polyvinyl siloxane impression material.

Authors:  Subash M Reddy; D Vijitha; S Karthikeyan; R Balasubramanian; A Satish
Journal:  J Indian Prosthodont Soc       Date:  2012-08-07

2.  Clinical success rates for polyether crown impressions when mixed dynamically and statically.

Authors:  Marc Schmitter; Glen H Johnson; Clovis Faggion; Christina Klose; Gergo Mitov; Frank P Nothdurft; Peter R Pospiech; Peter Rammelsberg; Brigitte Ohlmann; Stefanie Schwarz; Thomas Stober; Petra Schiller; Maria Pritsch
Journal:  Clin Oral Investig       Date:  2011-05-25       Impact factor: 3.573

3.  Randomized controlled clinical trial on the three-dimensional accuracy of fast-set impression materials.

Authors:  Heike Rudolph; Sebastian Quaas; Manuela Haim; Jörg Preißler; Michael H Walter; Rainer Koch; Ralph G Luthardt
Journal:  Clin Oral Investig       Date:  2012-08-31       Impact factor: 3.573

4.  Tear strength and elastic recovery of new generation hybrid elastomeric impression material: A comparative study.

Authors:  Lamia Singer; Christoph Bourauel; Shaymaa I Habib; Heba El-Amin Shalaby; Sayed H Saniour
Journal:  BMC Res Notes       Date:  2022-06-27

5.  Digital assessment of properties of the three different generations of dental elastomeric impression materials.

Authors:  Lamia Singer; Shaymaa I Habib; Heba El-Amin Shalaby; Sayed H Saniour; Christoph Bourauel
Journal:  BMC Oral Health       Date:  2022-09-05       Impact factor: 3.747

6.  Effect of Core Materials on the Dimensional Accuracy of Casts Made of Two Different Silicone Impression Materials: An Experimental Study.

Authors:  Mitra Farzin; Reza Derafshi; Rashin Giti; Mohammad-Hassan Kalantari
Journal:  J Int Soc Prev Community Dent       Date:  2020-03-05

7.  Dimensional Accuracy of Hydrophilic and Hydrophobic VPS Impression Materials Using Different Impression Techniques - An Invitro Study.

Authors:  Sreeramulu Basapogu; Ajai Pilla; Suman Pathipaka
Journal:  J Clin Diagn Res       Date:  2016-02-01

8.  Accuracy of a separating foil impression using a novel polyolefin foil compared to a custom tray and a stock tray technique.

Authors:  Marie-Hélène Pastoret; Gabriel Krastl; Julia Bühler; Roland Weiger; Nicola Ursula Zitzmann
Journal:  J Adv Prosthodont       Date:  2017-08-16       Impact factor: 1.904

9.  Accuracy of Gypsum Casts after Different Impression Techniques and Double Pouring.

Authors:  Stephania Caroline Rodolfo Silva; Aion Mangino Messias; Filipe de Oliveira Abi-Rached; Raphael Freitas de Souza; José Maurício Dos Santos Nunes Reis
Journal:  PLoS One       Date:  2016-10-13       Impact factor: 3.240

10.  A Comparison of implant impression precision: Different materials and techniques.

Authors:  Mahtab Tabesh; Marzieh Alikhasi; Hakimeh Siadat
Journal:  J Clin Exp Dent       Date:  2018-02-01
View more