Literature DB >> 20359168

Lensfree holographic imaging of antibody microarrays for high-throughput detection of leukocyte numbers and function.

Gulnaz Stybayeva1, Onur Mudanyali, Sungkyu Seo, Jaime Silangcruz, Monica Macal, Erlan Ramanculov, Satya Dandekar, Anthony Erlinger, Aydogan Ozcan, Alexander Revzin.   

Abstract

Characterization of leukocytes is an integral part of blood analysis and blood-based diagnostics. In the present paper, we combine lensless holographic imaging with antibody microarrays for rapid and multiparametric analysis of leukocytes from human blood. Monoclonal antibodies (Abs) specific for leukocyte surface antigens (CD4 and CD8) and cytokines (TNF-alpha, IFN-gamma, IL-2) were printed in an array so as to juxtapose cell capture and cytokine detection antibody (Ab) spots. Integration of Ab microarrays into a microfluidic flow chamber (4 muL volume) followed by incubation with human blood resulted in capture of CD4 and CD8 T-cells on specific Ab spots. On-chip mitogenic activation of these cells induced release of cytokine molecules that were subsequently captured on neighboring anticytokine Ab spots. The binding of IL-2, TNF-alpha, and IFN-gamma molecules on their respective Ab spots was detected using horseradish peroxidase (HRP)-labeled anticytokine Abs and a visible color reagent. Lensfree holographic imaging was then used to rapidly ( approximately 4 s) enumerate CD4 and CD8 T-lymphocytes captured on Ab spots and to quantify the cytokine signal emanating from IL-2, TNF-alpha, and IFN-gamma spots on the same chip. To demonstrate the utility of our approach for infectious disease monitoring, blood samples of healthy volunteers and human immunodeficiency virus (HIV)-infected patients were analyzed to determine the CD4/CD8 ratio, an important HIV/AIDS diagnostic marker. The ratio obtained by lensfree on-chip imaging of CD4 and CD8 T-cells captured on Ab spots was in close agreement with conventional microscopy-based cell counting. The present paper, describing tandem use of Ab microarrays and lensfree holographic imaging, paves the way for future development of miniature cytometry devices for multiparametric blood analysis at the point of care or in a resource-limited setting.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20359168      PMCID: PMC2864520          DOI: 10.1021/ac100142a

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  33 in total

Review 1.  Correlates of immune protection in HIV-1 infection: what we know, what we don't know, what we should know.

Authors:  Giuseppe Pantaleo; Richard A Koup
Journal:  Nat Med       Date:  2004-08       Impact factor: 53.440

2.  DNA-encoded antibody libraries: a unified platform for multiplexed cell sorting and detection of genes and proteins.

Authors:  Ryan C Bailey; Gabriel A Kwong; Caius G Radu; Owen N Witte; James R Heath
Journal:  J Am Chem Soc       Date:  2007-01-30       Impact factor: 15.419

3.  Ultra wide-field lens-free monitoring of cells on-chip.

Authors:  Aydogan Ozcan; Utkan Demirci
Journal:  Lab Chip       Date:  2007-11-01       Impact factor: 6.799

4.  Cell detection and counting through cell lysate impedance spectroscopy in microfluidic devices.

Authors:  Xuanhong Cheng; Yi-shao Liu; Daniel Irimia; Utkan Demirci; Liju Yang; Lee Zamir; William R Rodríguez; Mehmet Toner; Rashid Bashir
Journal:  Lab Chip       Date:  2007-05-11       Impact factor: 6.799

5.  Panning of multiple subsets of leukocytes on antibody-decorated poly(ethylene) glycol-coated glass slides.

Authors:  Kazuhiko Sekine; Alexander Revzin; Ronald G Tompkins; Mehmet Toner
Journal:  J Immunol Methods       Date:  2006-06-08       Impact factor: 2.303

Review 6.  Cytofluorometric methods for assessing absolute numbers of cell subsets in blood. European Working Group on Clinical Cell Analysis.

Authors:  B Brando; D Barnett; G Janossy; F Mandy; B Autran; G Rothe; B Scarpati; G D'Avanzo; J L D'Hautcourt; R Lenkei; G Schmitz; A Kunkl; R Chianese; S Papa; J W Gratama
Journal:  Cytometry       Date:  2000-12-15

7.  A miniature cytometry platform for capture and characterization of T-lymphocytes from human blood.

Authors:  He Zhu; Monica Macal; Caroline N Jones; Michael D George; Satya Dandekar; Alexander Revzin
Journal:  Anal Chim Acta       Date:  2007-12-28       Impact factor: 6.558

8.  Enhancing the performance of a point-of-care CD4+ T-cell counting microchip through monocyte depletion for HIV/AIDS diagnostics.

Authors:  Xuanhong Cheng; Amit Gupta; Chihchen Chen; Ronald G Tompkins; William Rodriguez; Mehmet Toner
Journal:  Lab Chip       Date:  2009-02-04       Impact factor: 6.799

9.  Lensfree holographic imaging for on-chip cytometry and diagnostics.

Authors:  Sungkyu Seo; Ting-Wei Su; Derek K Tseng; Anthony Erlinger; Aydogan Ozcan
Journal:  Lab Chip       Date:  2008-12-05       Impact factor: 6.799

10.  CD4+ T cell depletion during all stages of HIV disease occurs predominantly in the gastrointestinal tract.

Authors:  Jason M Brenchley; Timothy W Schacker; Laura E Ruff; David A Price; Jodie H Taylor; Gregory J Beilman; Phuong L Nguyen; Alexander Khoruts; Matthew Larson; Ashley T Haase; Daniel C Douek
Journal:  J Exp Med       Date:  2004-09-13       Impact factor: 14.307

View more
  29 in total

1.  Biosensors for immune cell analysis-A perspective.

Authors:  Alexander Revzin; Emanual Maverakis; H-C Chang
Journal:  Biomicrofluidics       Date:  2012-04-26       Impact factor: 2.800

2.  Reconfigurable microfluidic device with integrated antibody arrays for capture, multiplexed stimulation, and cytokine profiling of human monocytes.

Authors:  Tam Vu; Ali Rahimian; Gulnaz Stybayeva; Yandong Gao; Timothy Kwa; Judy Van de Water; Alexander Revzin
Journal:  Biomicrofluidics       Date:  2015-08-06       Impact factor: 2.800

3.  Micropatterned aptasensors for continuous monitoring of cytokine release from human leukocytes.

Authors:  Ying Liu; Jun Yan; Michael C Howland; Timothy Kwa; Alexander Revzin
Journal:  Anal Chem       Date:  2011-10-13       Impact factor: 6.986

4.  Simultaneous detection of cell-secreted TNF-α and IFN-γ using micropatterned aptamer-modified electrodes.

Authors:  Ying Liu; Timothy Kwa; Alexander Revzin
Journal:  Biomaterials       Date:  2012-07-17       Impact factor: 12.479

5.  Reconfigurable microfluidics combined with antibody microarrays for enhanced detection of T-cell secreted cytokines.

Authors:  Arnold Chen; Tam Vu; Gulnaz Stybayeva; Tingrui Pan; Alexander Revzin
Journal:  Biomicrofluidics       Date:  2013-03-14       Impact factor: 2.800

Review 6.  Tackling HIV through robust diagnostics in the developing world: current status and future opportunities.

Authors:  Darash Desai; Grace Wu; Muhammad H Zaman
Journal:  Lab Chip       Date:  2010-12-01       Impact factor: 6.799

7.  One-incubation one-hour multiplex ELISA enabled by aqueous two-phase systems.

Authors:  Mintra Tongdee; Cameron Yamanishi; Midori Maeda; Taisuke Kojima; John Dishinger; Rattikan Chantiwas; Shuichi Takayama
Journal:  Analyst       Date:  2020-05-18       Impact factor: 4.616

8.  Photodegradable hydrogels for capture, detection, and release of live cells.

Authors:  Dong-Sik Shin; Jungmok You; Ali Rahimian; Tam Vu; Christian Siltanen; Arshia Ehsanipour; Gulnaz Stybayeva; Julie Sutcliffe; Alexander Revzin
Journal:  Angew Chem Int Ed Engl       Date:  2014-06-16       Impact factor: 15.336

9.  Micropatterning of Aptamer Beacons to Create Cytokine-Sensing Surfaces.

Authors:  Nazgul Tuleuova; Alexander Revzin
Journal:  Cell Mol Bioeng       Date:  2010-11-20       Impact factor: 2.321

Review 10.  Optical imaging techniques for point-of-care diagnostics.

Authors:  Hongying Zhu; Serhan O Isikman; Onur Mudanyali; Alon Greenbaum; Aydogan Ozcan
Journal:  Lab Chip       Date:  2012-10-09       Impact factor: 6.799

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.