Literature DB >> 26339315

Reconfigurable microfluidic device with integrated antibody arrays for capture, multiplexed stimulation, and cytokine profiling of human monocytes.

Tam Vu1, Ali Rahimian1, Gulnaz Stybayeva1, Yandong Gao1, Timothy Kwa1, Judy Van de Water2, Alexander Revzin1.   

Abstract

Monocytes represent a class of immune cells that play a key role in the innate and adaptive immune response against infections. One mechanism employed by monocytes for sensing foreign antigens is via toll-like receptors (TLRs)-transmembrane proteins that distinguish classes of foreign pathogens, for example, bacteria (TLR4, 5, and 9) vs. fungi (TLR2) vs. viruses (TLR3, 7, and 8). Binding of antigens activates a signaling cascade through TLR receptors that culminate in secretion of inflammatory cytokines. Detection of these cytokines can provide valuable clinical data for drug developers and disease investigations, but this usually requires a large sample volume and can be technically inefficient with traditional techniques such as flow cytometry, enzyme-linked immunosorbent assay, or luminex. This paper describes an approach whereby antibody arrays for capturing cells and secreted cytokines are encapsulated within a microfluidic device that can be reconfigured to operate in serial or parallel mode. In serial mode, the device represents one long channel that may be perfused with a small volume of minimally processed blood. Once monocytes are captured onto antibody spots imprinted into the floor of the device, the straight channel is reconfigured to form nine individually perfusable chambers. To prove this concept, the microfluidic platform was used to capture monocytes from minimally processed human blood in serial mode and then to stimulate monocytes with different TLR agonists in parallel mode. Three cytokines, tumor necrosis factor-α, interleukin (IL)-6, and IL-10, were detected using anti-cytokine antibody arrays integrated into each of the six chambers. We foresee further use of this device in applications such as pediatric immunology or drug/vaccine testing where it is important to balance small sample volume with the need for high information content.

Entities:  

Year:  2015        PMID: 26339315      PMCID: PMC4529433          DOI: 10.1063/1.4928128

Source DB:  PubMed          Journal:  Biomicrofluidics        ISSN: 1932-1058            Impact factor:   2.800


  40 in total

Review 1.  A new era in pyrogen testing.

Authors:  J L Ding; B Ho
Journal:  Trends Biotechnol       Date:  2001-08       Impact factor: 19.536

Review 2.  Microbial recognition by Toll-like receptors.

Authors:  Kiyoshi Takeda; Shizuo Akira
Journal:  J Dermatol Sci       Date:  2004-04       Impact factor: 4.563

3.  Measurement of serum cytokines.

Authors:  A Barnes
Journal:  Lancet       Date:  1998-07-25       Impact factor: 79.321

4.  Altered monocyte responses to defined TLR ligands in patients with primary biliary cirrhosis.

Authors:  Tin Ky Mao; Zhe-Xiong Lian; Carlo Selmi; Yasunori Ichiki; Paul Ashwood; Aftab A Ansari; Ross L Coppel; Shinji Shimoda; Hiromi Ishibashi; M Eric Gershwin
Journal:  Hepatology       Date:  2005-10       Impact factor: 17.425

5.  Rapid Prototyping of Microfluidic Systems in Poly(dimethylsiloxane).

Authors:  D C Duffy; J C McDonald; O J Schueller; G M Whitesides
Journal:  Anal Chem       Date:  1998-12-01       Impact factor: 6.986

6.  Panning of multiple subsets of leukocytes on antibody-decorated poly(ethylene) glycol-coated glass slides.

Authors:  Kazuhiko Sekine; Alexander Revzin; Ronald G Tompkins; Mehmet Toner
Journal:  J Immunol Methods       Date:  2006-06-08       Impact factor: 2.303

7.  An integrated microfluidic platform for in situ cellular cytokine secretion immunophenotyping.

Authors:  Nien-Tsu Huang; Weiqiang Chen; Bo-Ram Oh; Timothy T Cornell; Thomas P Shanley; Jianping Fu; Katsuo Kurabayashi
Journal:  Lab Chip       Date:  2012-10-21       Impact factor: 6.799

8.  A miniature cytometry platform for capture and characterization of T-lymphocytes from human blood.

Authors:  He Zhu; Monica Macal; Caroline N Jones; Michael D George; Satya Dandekar; Alexander Revzin
Journal:  Anal Chim Acta       Date:  2007-12-28       Impact factor: 6.558

9.  Enhancing the performance of a point-of-care CD4+ T-cell counting microchip through monocyte depletion for HIV/AIDS diagnostics.

Authors:  Xuanhong Cheng; Amit Gupta; Chihchen Chen; Ronald G Tompkins; William Rodriguez; Mehmet Toner
Journal:  Lab Chip       Date:  2009-02-04       Impact factor: 6.799

10.  Defective response to Toll-like receptor 3 and 4 ligands by activated monocytes in chronic hepatitis C virus infection.

Authors:  M C Villacres; O Literat; M DeGiacomo; W Du; T Frederick; A Kovacs
Journal:  J Viral Hepat       Date:  2008-02       Impact factor: 3.728

View more
  5 in total

Review 1.  Big insights from small volumes: deciphering complex leukocyte behaviors using microfluidics.

Authors:  Daniel Irimia; Felix Ellett
Journal:  J Leukoc Biol       Date:  2016-05-18       Impact factor: 4.962

2.  Microfluidic system for immune cell activation and inflammatory cytokine profiling: Application to screening of dietary supplements for anti-inflammatory properties.

Authors:  Qasem Ramadan; Hawra Alawami; Mohammed Zourob
Journal:  Biomicrofluidics       Date:  2022-10-10       Impact factor: 3.258

3.  Monocyte Distribution Width: A Novel Indicator of Sepsis-2 and Sepsis-3 in High-Risk Emergency Department Patients.

Authors:  Elliott D Crouser; Joseph E Parrillo; Christopher W Seymour; Derek C Angus; Keri Bicking; Vincent G Esguerra; Octavia M Peck-Palmer; Robert T Magari; Mark W Julian; Jennifer M Kleven; Paarth J Raj; Gabrielle Procopio; Diana Careaga; Liliana Tejidor
Journal:  Crit Care Med       Date:  2019-08       Impact factor: 7.598

4.  Ultrasensitive Multiparameter Phenotyping of Rare Cells Using an Integrated Digital-Molecular-Counting Microfluidic Well Plate.

Authors:  Shiuan-Haur Su; Yujing Song; Michael W Newstead; Tao Cai; MengXi Wu; Andrew Stephens; Benjamin H Singer; Katsuo Kurabayashi
Journal:  Small       Date:  2021-06-25       Impact factor: 15.153

Review 5.  Recent Progress in Lab-On-a-Chip Systems for the Monitoring of Metabolites for Mammalian and Microbial Cell Research.

Authors:  Esma Dervisevic; Kellie L Tuck; Nicolas H Voelcker; Victor J Cadarso
Journal:  Sensors (Basel)       Date:  2019-11-18       Impact factor: 3.576

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.