Literature DB >> 20358370

MR-guided freehand biopsy of liver lesions with fast continuous imaging using a 1.0-T open MRI scanner: experience in 50 patients.

Frank Fischbach1, Jürgen Bunke, Markus Thormann, Gunnar Gaffke, Kerstin Jungnickel, Jouke Smink, Jens Ricke.   

Abstract

The purpose of this study was to assess a new open system with a field-strength of 1.0 T for the feasibility of liver biopsy using the freehand technique with fast continuous imaging. Fifty patients with focal liver lesions measuring 5 to 30 mm in diameter were included in the study. Guidance and monitoring was performed using a 1.0-T open magnetic resonance (MR) scanner (Panorama HFO; Philips Healthcare, Best, The Netherlands). With fast continuous imaging using a T1-weighted (T1W) gradient echo (GRE) sequence after administration of gadolinium (Gd)-EOB-DTPA, the needle was placed into the lesion. An interface for interactive dynamic viewing in two perpendicular planes prevented needle deviations T2-weighted turbo spin echo (TSE) fat-suppressed sequence was added to rule out postinterventional hematoma or biloma. All lesions were visible on the interventional images. Biopsy was technically successful, and solid specimens were obtained in all cases. Forty-six patients showed a histopathologic pattern other than native liver tissue, thus confirming correct position of the needle. Time between determination of the lesion and performance of the control scan was on average 18 min. No major complications were recorded. MR guidance with the new 1-T open system must be considered an attractive alternative for liver punction. An interface for dynamic imaging of needle guidance and T1W-GRE imaging with administration of Gd-EOB-DTPA for contrast enhancement allows the pinpoint puncture of liver lesions.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20358370     DOI: 10.1007/s00270-010-9836-8

Source DB:  PubMed          Journal:  Cardiovasc Intervent Radiol        ISSN: 0174-1551            Impact factor:   2.740


  14 in total

1.  Performing MR-guided biopsies in clinical routine: factors that influence accuracy and procedure time.

Authors:  Rüdiger Hoffmann; Christoph Thomas; Hansjörg Rempp; Diethard Schmidt; Philippe L Pereira; Claus D Claussen; Stephan Clasen
Journal:  Eur Radiol       Date:  2011-09-30       Impact factor: 5.315

2.  [Percutaneous interventions in an open MR system: technical background and clinical indications].

Authors:  F Fischbach; K Fischbach; J Ricke
Journal:  Radiologe       Date:  2013-11       Impact factor: 0.635

3.  Auditory feedback to support image-guided medical needle placement.

Authors:  David Black; Julian Hettig; Maria Luz; Christian Hansen; Ron Kikinis; Horst Hahn
Journal:  Int J Comput Assist Radiol Surg       Date:  2017-02-17       Impact factor: 2.924

4.  Real-time MR-guided brain biopsy using 1.0-T open MRI scanner.

Authors:  Xiangmeng He; Ming Liu; Chao Liu; Jing Fang; Yujun Xu; Ligang Wang; Jianfeng Xiang; Roberto Blanco Sequeiros; Chengli Li
Journal:  Eur Radiol       Date:  2018-06-12       Impact factor: 5.315

5.  Evaluation of percutaneous biopsies of renal masses under MRI-guidance: a retrospective study about 26 cases.

Authors:  J Garnon; A Schlier; X Buy; G Tsoumakidou; M de Mathelin; E Breton; A Gangi
Journal:  Eur Radiol       Date:  2014-10-15       Impact factor: 5.315

6.  MR-guided radiofrequency ablation using a wide-bore 1.5-T MR system: clinical results of 213 treated liver lesions.

Authors:  Hansjörg Rempp; Lorenz Waibel; Rüdiger Hoffmann; Claus D Claussen; Philippe L Pereira; Stephan Clasen
Journal:  Eur Radiol       Date:  2012-04-18       Impact factor: 5.315

7.  Wireless mobile technology to improve workflow and feasibility of MR-guided percutaneous interventions.

Authors:  Martin A Rube; Andrew B Holbrook; Benjamin F Cox; Razvan Buciuc; Andreas Melzer
Journal:  Int J Comput Assist Radiol Surg       Date:  2014-09-02       Impact factor: 2.924

8.  Feasibility study of MR-guided transgluteal targeted in-bore biopsy for suspicious lesions of the prostate at 3 Tesla using a freehand approach.

Authors:  Frank Fischbach; Lukas Wien; Sascha Krueger; Bernhard Schnackenburg; Daniel Baumunk; Björn Friebe; Martin Schostak; Jens Ricke; Katharina Fischbach
Journal:  Eur Radiol       Date:  2018-01-17       Impact factor: 5.315

9.  Targeting Accuracy, Procedure Times and User Experience of 240 Experimental MRI Biopsies Guided by a Clinical Add-On Navigation System.

Authors:  Harald Busse; Tim Riedel; Nikita Garnov; Gregor Thörmer; Thomas Kahn; Michael Moche
Journal:  PLoS One       Date:  2015-07-29       Impact factor: 3.240

10.  Navigated MRI-guided liver biopsies in a closed-bore scanner: experience in 52 patients.

Authors:  Michael Moche; Susann Heinig; Nikita Garnov; Jochen Fuchs; Tim-Ole Petersen; Daniel Seider; Philipp Brandmaier; Thomas Kahn; Harald Busse
Journal:  Eur Radiol       Date:  2015-11-12       Impact factor: 5.315

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.