Literature DB >> 20356807

Rapid confirmatory method for the determination of sixteen synthetic growth promoters and bisphenol A in bovine milk using dispersive solid-phase extraction and liquid chromatography-tandem mass spectrometry.

E M Malone1, C T Elliott, D G Kennedy, L Regan.   

Abstract

A rapid liquid chromatographic-tandem mass spectrometric (LC-MS/MS) multi-residue method for the simultaneous quantitation and identification of sixteen synthetic growth promoters and bisphenol A in bovine milk has been developed and validated. Sample preparation was straightforward, efficient and economically advantageous. Milk was extracted with acetonitrile followed by phase separation with NaCl. After centrifugation, the extract was purified by dispersive solid-phase extraction with C18 sorbent material. The compounds were analysed by reversed-phase LC-MS/MS using both positive and negative ionization and operated in multiple reaction monitoring (MRM) mode, acquiring two diagnostic product ions from each of the chosen precursor ions for unambiguous confirmation. Total chromatographic run time was less than 10 min for each sample. The method was validated at a level of 1 microg L(-1). A wide variety of deuterated internal standards were used to improve method performance. The accuracy and precision of the method were satisfactory for all analytes. The confirmative quantitative liquid chromatographic tandem mass spectrometric (LC-MS/MS) method was validated according to Commission Decision 2002/657/EC. The decision limit (CCalpha) and the detection capability (CCbeta) were found to be below the chosen validation level of 1 microg L(-1) for all compounds. 2010 Elsevier B.V. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20356807     DOI: 10.1016/j.jchromb.2010.03.012

Source DB:  PubMed          Journal:  J Chromatogr B Analyt Technol Biomed Life Sci        ISSN: 1570-0232            Impact factor:   3.205


  4 in total

Review 1.  Dispersive Solid Phase Extraction for the Analysis of Veterinary Drugs Applied to Food Samples: A Review.

Authors:  Gabriela Islas; Israel S Ibarra; Prisciliano Hernandez; Jose M Miranda; Alberto Cepeda
Journal:  Int J Anal Chem       Date:  2017-10-18       Impact factor: 1.885

2.  An Electrochemical Sensor Based on Gold Nanodendrite/Surfactant Modified Electrode for Bisphenol A Detection.

Authors:  Nguyen Thi Lien; Le Quoc Hung; Nguyen Tien Hoang; Vu Thi Thu; Dau Thi Ngoc Nga; Pham Thi Hai Yen; Pham Hong Phong; Vu Thi Thu Ha
Journal:  J Anal Methods Chem       Date:  2020-12-29       Impact factor: 2.193

3.  Determination of Trichlorfon Pesticide Residues in Milk via Gas Chromatography with μ-Electron Capture Detection and GC-MS.

Authors:  Lina Hem; Sathya Khay; Jeong-Heui Choi; E D Morgan; A M Abd El-Aty; Jae-Han Shim
Journal:  Toxicol Res       Date:  2010-06

4.  Comparison of the Multiple Reaction Monitoring and Enhanced Product Ion Scan Modes for Confirmation of Stilbenes in Bovine Urine Samples Using LC-MS/MS QTRAP® System.

Authors:  Iwona Matraszek-Zuchowska; Barbara Wozniak; Andrzej Posyniak
Journal:  Chromatographia       Date:  2016-07-05       Impact factor: 2.044

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.