Fast transient analysis and first-stage collision-induced dissociation with the flowing atmospheric-pressure afterglow ionization source to improve analyte detection and identification.

Jacob T Shelley1, Gary M Hieftje.   

Abstract

The recent development of ambient desorption/ionization mass spectrometry (ADI-MS) has enabled fast, simple analysis of many different sample types. The ADI-MS sources have numerous advantages, including little or no required sample pre-treatment, simple mass spectra, and direct analysis of solids and liquids. However, problems of competitive ionization and limited fragmentation require sample-constituent separation, high mass accuracy, and/or tandem mass spectrometry (MS/MS) to detect, identify, and quantify unknown analytes. To maintain the inherent high throughput of ADI-MS, it is essential for the ion source/mass analyzer combination to measure fast transient signals and provide structural information. In the current study, the flowing atmospheric-pressure afterglow (FAPA) ionization source is coupled with a time-of-flight mass spectrometer (TOF-MS) to analyze fast transient signals (<500 ms FWHM). It was found that gas chromatography (GC) coupled with the FAPA source resulted in a reproducible (<5% RSD) and sensitive (detection limits of <6 fmol for a mixture of herbicides) system with analysis times of ca. 5 min. Introducing analytes to the FAPA in a transient was also shown to significantly reduce matrix effects caused by competitive ionization by minimizing the number and amount of constituents introduced into the ionization source. Additionally, MS/MS with FAPA-TOF-MS, enabling analyte identification, was performed via first-stage collision-induced dissociation (CID). Lastly, molecular and structural information was obtained across a fast transient peak by modulating the conditions that caused the first-stage CID.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20349535     DOI: 10.1039/b927389a

Source DB:  PubMed          Journal:  Analyst        ISSN: 0003-2654            Impact factor:   4.616


  4 in total

1.  Halo-shaped flowing atmospheric pressure afterglow: a heavenly design for simplified sample introduction and improved ionization in ambient mass spectrometry.

Authors:  Kevin P Pfeuffer; J Niklas Schaper; Jacob T Shelley; Steven J Ray; George C-Y Chan; Nicolas H Bings; Gary M Hieftje
Journal:  Anal Chem       Date:  2013-07-15       Impact factor: 6.986

2.  Drop-on-demand sample introduction system coupled with the flowing atmospheric-pressure afterglow for direct molecular analysis of complex liquid microvolume samples.

Authors:  J Niklas Schaper; Kevin P Pfeuffer; Jacob T Shelley; Nicolas H Bings; Gary M Hieftje
Journal:  Anal Chem       Date:  2012-10-25       Impact factor: 6.986

3.  Ultrasensitive ambient mass spectrometric analysis with a pin-to-capillary flowing atmospheric-pressure afterglow source.

Authors:  Jacob T Shelley; Joshua S Wiley; Gary M Hieftje
Journal:  Anal Chem       Date:  2011-06-16       Impact factor: 6.986

4.  Measurement and visualization of mass transport for the flowing atmospheric pressure afterglow (FAPA) ambient mass-spectrometry source.

Authors:  Kevin P Pfeuffer; Steven J Ray; Gary M Hieftje
Journal:  J Am Soc Mass Spectrom       Date:  2014-05       Impact factor: 3.109

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.