Literature DB >> 23025277

Drop-on-demand sample introduction system coupled with the flowing atmospheric-pressure afterglow for direct molecular analysis of complex liquid microvolume samples.

J Niklas Schaper1, Kevin P Pfeuffer, Jacob T Shelley, Nicolas H Bings, Gary M Hieftje.   

Abstract

One of the fastest developing fields in analytical spectrochemistry in recent years is ambient desorption/ionization mass spectrometry (ADI-MS). This burgeoning interest has been due to the demonstrated advantages of the method: simple mass spectra, little or no sample preparation, and applicability to samples in the solid, liquid, or gaseous state. One such ADI-MS source, the flowing atmospheric-pressure afterglow (FAPA), is capable of direct analysis of solids just by aiming the source at the solid surface and sampling the produced ions into a mass spectrometer. However, direct introduction of significant volumes of liquid samples into this source has not been possible, as solvent loads can quench the afterglow and, thus, the formation of reagent ions. As a result, the analysis of liquid samples is preferably carried out by analyzing dried residues or by desorbing small amounts of liquid samples directly from the liquid surface. In the former case, reproducibility of sample introduction is crucial if quantitative results are desired. In the present study, introduction of liquid samples as very small droplets helps overcome the issues of sample positioning and reduced levels of solvent intake. A recently developed "drop-on-demand" (DOD) aerosol generator is capable of reproducibly producing very small volumes of liquid (∼17 pL). In this paper, the coupling of FAPA-MS and DOD is reported and applications are suggested. Analytes representing different classes of substances were tested and limits of detections were determined. Matrix tolerance was investigated for drugs of abuse and their metabolites by analyzing raw urine samples and quantification without the use of internal standards. Limits of detection below 2 μg/mL, without sample pretreatment, were obtained.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 23025277      PMCID: PMC3510665          DOI: 10.1021/ac3020164

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  24 in total

1.  Versatile new ion source for the analysis of materials in open air under ambient conditions.

Authors:  Robert B Cody; James A Laramée; H Dupont Durst
Journal:  Anal Chem       Date:  2005-04-15       Impact factor: 6.986

2.  Atmospheric pressure chemical ionization source. 2. Desorption-ionization for the direct analysis of solid compounds.

Authors:  Francisco J Andrade; Jacob T Shelley; William C Wetzel; Michael R Webb; Gerardo Gamez; Steven J Ray; Gary M Hieftje
Journal:  Anal Chem       Date:  2008-03-18       Impact factor: 6.986

3.  Combination atmospheric pressure solids analysis probe and desorption electrospray ionization mass spectrometry ion source.

Authors:  Julie A Lloyd; Andrew F Harron; Charles N McEwen
Journal:  Anal Chem       Date:  2009-11-01       Impact factor: 6.986

4.  Picoliter droplet deposition using a prototype picoliter pipette: control parameters and application in micro X-ray fluorescence.

Authors:  Ursula E A Fittschen; George J Havrilla
Journal:  Anal Chem       Date:  2010-01-01       Impact factor: 6.986

5.  Validity testing of commercial urine cocaine metabolite assays: II. Sensitivity, specificity, accuracy, and confirmation by gas chromatography/mass spectrometry.

Authors:  E J Cone; J Mitchell
Journal:  J Forensic Sci       Date:  1989-01       Impact factor: 1.832

6.  Ultrasensitive ambient mass spectrometric analysis with a pin-to-capillary flowing atmospheric-pressure afterglow source.

Authors:  Jacob T Shelley; Joshua S Wiley; Gary M Hieftje
Journal:  Anal Chem       Date:  2011-06-16       Impact factor: 6.986

7.  [Simple and rapid screening for methamphetamine and 3,4-methylenedioxymethamphetamine (MDMA) and their metabolites in urine using direct analysis in real time (DART)-TOFMS].

Authors:  Maiko Kawamura; Ruri Kikura-Hanajiri; Yukihiro Goda
Journal:  Yakugaku Zasshi       Date:  2011       Impact factor: 0.302

Review 8.  Experience with urine drug testing by the Correctional Service of Canada.

Authors:  A D Fraser; J Zamecnik; J Keravel; L McGrath; J Wells
Journal:  Forensic Sci Int       Date:  2001-09-15       Impact factor: 2.395

9.  Fast GC-MS method for the simultaneous screening of THC-COOH, cocaine, opiates and analogues including buprenorphine and fentanyl, and their metabolites in urine.

Authors:  Sabina Strano-Rossi; Ana Maria Bermejo; Xavier de la Torre; Francesco Botrè
Journal:  Anal Bioanal Chem       Date:  2010-12-12       Impact factor: 4.142

10.  Atmospheric pressure chemical ionization source. 1. Ionization of compounds in the gas phase.

Authors:  Francisco J Andrade; Jacob T Shelley; William C Wetzel; Michael R Webb; Gerardo Gamez; Steven J Ray; Gary M Hieftje
Journal:  Anal Chem       Date:  2008-03-18       Impact factor: 6.986

View more
  2 in total

1.  Multimodal Vacuum-Assisted Plasma Ion (VaPI) Source with Transmission Mode and Laser Ablation Sampling Capabilities.

Authors:  Joel D Keelor; Paul B Farnsworth; Arthur L Weber; Heather Abbott-Lyon; Facundo M Fernández
Journal:  J Am Soc Mass Spectrom       Date:  2016-02-16       Impact factor: 3.109

2.  Halo-shaped flowing atmospheric pressure afterglow: a heavenly design for simplified sample introduction and improved ionization in ambient mass spectrometry.

Authors:  Kevin P Pfeuffer; J Niklas Schaper; Jacob T Shelley; Steven J Ray; George C-Y Chan; Nicolas H Bings; Gary M Hieftje
Journal:  Anal Chem       Date:  2013-07-15       Impact factor: 6.986

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.