Literature DB >> 20348409

Establishment of outcome-related analytic performance goals.

George G Klee1.   

Abstract

BACKGROUND: Accrediting organizations require laboratories to establish analytic performance criteria that ensure their tests provide results of the high quality required for patient care. However, the procedures for instituting performance criteria that are directly linked to the needs of medical practice are not well established, and therefore alternative strategies often are used to create and implement surrogate performance standards. CONTENT: We reviewed 6 approaches for establishing outcome-related analytic performance goals: (a) limits defined by regulations and external assessment programs, (b) limits based on biologic variation, (c) limits based on surveys of clinicians about their needs, (d) limits based on effects on guideline driven medical decisions, (e) limits based on analysis of patterns for ordering follow-up clinical tests, and (f) limits based on formal medical decision models. Performance criteria were tabulated for 12 common chemistry analytes and 4 routine hematology tests.
CONCLUSIONS: There is no consensus currently about the preferred methods for establishing medically necessary analytic performance limits. The various methods reviewed give considerably different performance limits. The analytic performance limits claimed by a laboratory should correspond to those limits that can be reliably maintained based on validated QC monitoring systems. These limits generally are larger than the observed CVs and bias parameters collected for assay validation. There is a major need for increased communication among laboratorians and clinicians on this topic, especially when the analytic performance limits that can be consistently maintained by a laboratory are inconsistent with the expectations of health care providers.

Entities:  

Mesh:

Year:  2010        PMID: 20348409     DOI: 10.1373/clinchem.2009.133660

Source DB:  PubMed          Journal:  Clin Chem        ISSN: 0009-9147            Impact factor:   8.327


  10 in total

1.  Uncertainty of Measurement: A Review of the Rules for Calculating Uncertainty Components through Functional Relationships.

Authors:  Ian Farrance; Robert Frenkel
Journal:  Clin Biochem Rev       Date:  2012-05

Review 2.  Toward a Framework for Outcome-Based Analytical Performance Specifications: A Methodology Review of Indirect Methods for Evaluating the Impact of Measurement Uncertainty on Clinical Outcomes.

Authors:  Alison F Smith; Bethany Shinkins; Peter S Hall; Claire T Hulme; Mike P Messenger
Journal:  Clin Chem       Date:  2019-08-23       Impact factor: 8.327

3.  Application of Sigma Metrics Analysis for the Assessment and Modification of Quality Control Program in the Clinical Chemistry Laboratory of a Tertiary Care Hospital.

Authors:  Sahar Iqbal; Tazeen Mustansar
Journal:  Indian J Clin Biochem       Date:  2016-04-07

4.  LEGO plot for simultaneous application of multiple quality requirements during trueness verification of quantitative laboratory tests.

Authors:  Hae-il Park; Hyojin Chae; Myungshin Kim; Jehoon Lee; Yonggoo Kim
Journal:  J Clin Lab Anal       Date:  2014-01-06       Impact factor: 2.352

5.  Three-year monitoring and comparison of results from two identical blood gas analyzers.

Authors:  Yun Huang; Robert Dean; Yvonne Dubbelman; Anne Vincent; Ying-Pui Michael Chan
Journal:  Pract Lab Med       Date:  2022-06-03

6.  Repeating tests: different roles in research studies and clinical medicine.

Authors:  Paul A Monach
Journal:  Biomark Med       Date:  2012-10       Impact factor: 2.851

Review 7.  Performance of laboratory tests used to measure blood phenylalanine for the monitoring of patients with phenylketonuria.

Authors:  Stuart J Moat; Danja Schulenburg-Brand; Hugh Lemonde; James R Bonham; Cas W Weykamp; Joanne V Mei; Graham S Shortland; Rachel S Carling
Journal:  J Inherit Metab Dis       Date:  2019-10-02       Impact factor: 4.750

8.  External Quality Assessment Schemes in Latin America.

Authors:  Gabriel Alejandro Migliarino
Journal:  EJIFCC       Date:  2015-11-27

9.  Failure of internal quality control in detecting significant reagent lot shift in serum creatinine measurement.

Authors:  Xiaoting Chen; Jia Wang; Wei Zhang; Erfu Xie; Bingfeng Zhang; Hua-Guo Xu
Journal:  J Clin Lab Anal       Date:  2019-08-02       Impact factor: 2.352

10.  Short-term biological variation and Reference change values of urinary 8-oxo-7,8-dihydro-2'-deoxyguanosine and 8-oxo-7,8-dihydroguanosine.

Authors:  Ruiping Zhang; Songlin Yu; Danchen Wang; Yicong Yin; Jialei Yu; Yongtong Cao; Ling Qiu
Journal:  J Clin Lab Anal       Date:  2020-08-22       Impact factor: 3.124

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.