Literature DB >> 20335762

Intraoperative measurement of mounting parameters for the Taylor Spatial Frame.

George D Gantsoudes1, Austin T Fragomen, S Robert Rozbruch.   

Abstract

The Taylor Spatial Frame (Smith & Nephew, Memphis, TN) is a powerful tool in providing gradual correction of deformity. The Taylor Spatial Frame has the potential to allow for very accurate corrections achieved over one or more schedules through the use of the software on www.spatialframe.com. The accuracy of the frame is contingent upon the input of precise parameters. The correction occurs about a virtual hinge in space called the origin. The location of the origin is defined by its spatial relationship to the reference ring. Mounting parameters are the measurements that define the location of the origin (virtual hinge). We present a simple practical method for obtaining mounting parameters during surgery using standard equipment.

Entities:  

Mesh:

Year:  2010        PMID: 20335762     DOI: 10.1097/BOT.0b013e3181c2f7f0

Source DB:  PubMed          Journal:  J Orthop Trauma        ISSN: 0890-5339            Impact factor:   2.512


  13 in total

1.  Does lengthening and then plating (LAP) shorten duration of external fixation?

Authors:  Ryhor Harbacheuski; Austin T Fragomen; S Robert Rozbruch
Journal:  Clin Orthop Relat Res       Date:  2011-11-15       Impact factor: 4.176

2.  Complex ankle arthrodesis using the Ilizarov method yields high rate of fusion.

Authors:  Austin T Fragomen; Eugene Borst; Lindsay Schachter; Stephen Lyman; S Robert Rozbruch
Journal:  Clin Orthop Relat Res       Date:  2012-07-10       Impact factor: 4.176

3.  [Correction of posttraumatic lower leg deformities using the Taylor Spatial Frame].

Authors:  D Krappinger; M Zegg; V Smekal; B Huber
Journal:  Oper Orthop Traumatol       Date:  2014-10       Impact factor: 1.154

4.  Does Integrated Fixation Provide Benefit in the Reconstruction of Posttraumatic Tibial Bone Defects?

Authors:  Mitchell Bernstein; Austin T Fragomen; Samir Sabharwal; Jonathan Barclay; S Robert Rozbruch
Journal:  Clin Orthop Relat Res       Date:  2015-10       Impact factor: 4.176

5.  Distance from the magnification device contributes to differences in lower leg length measured in patients with TSF correction.

Authors:  Marc-Daniel Ahrend; Michael Rühle; Fabian Springer; Heiko Baumgartner
Journal:  Arch Orthop Trauma Surg       Date:  2021-03-06       Impact factor: 2.928

6.  The silhouette technique: improving post-operative radiographs for planning of correction with a hexapod external fixator.

Authors:  Jonathan Wright; Shiraz A Sabah; Shelain Patel; Gavin Spence
Journal:  Strategies Trauma Limb Reconstr       Date:  2017-05-12

7.  Biomechanical and Functional Improvements Gained by Proximal Tibia Osteotomy Correction of Genu Varum in Patients with Knee Pain.

Authors:  Rachael J Da Cunha; Andrew P Kraszewski; Howard J Hillstrom; Austin T Fragomen; S Robert Rozbruch
Journal:  HSS J       Date:  2019-03-19

8.  Treatment of open fractures with a computer-assisted external fixator system without the use of fluoroscopy.

Authors:  Adnan Kara; Haluk Celik; Ali Seker; Ozgur Karakoyun; Raffi Armagan; Ersin Kuyucu; Mehmet Erdil
Journal:  J Orthop Surg Res       Date:  2016-04-26       Impact factor: 2.359

9.  Chronic Osteomyelitis of the tibia and ankle treated with Limb Salvage Reconstruction.

Authors:  Aaron Lam; Shawn S Richardson; Josh Buksbaum; Jonathan Markowitz; Michael W Henry; Andy O Miller; S Robert Rozbruch; Austin T Fragomen
Journal:  J Bone Jt Infect       Date:  2019-12-10

10.  Long bone fracture reduction and deformity correction using the hexapod external fixator with a new method: a feasible study and preliminary results.

Authors:  Yanshi Liu; Hong Li; Jialin Liu; Xingpeng Zhang; Maimaiaili Yushan; Zhenhui Liu; Chuang Ma; Aihemaitijiang Yusufu
Journal:  BMC Musculoskelet Disord       Date:  2021-02-24       Impact factor: 2.362

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.