Literature DB >> 2032979

Retention and clearance of 0.9-micron particles inhaled by hamsters during rest or exercise.

T B Zeltner1, T D Sweeney, W A Skornik, H A Feldman, J D Brain.   

Abstract

We assessed the retention and clearance of inhaled particles in six anatomic compartments of the respiratory tract. Hamsters were exposed for 45 min to 0.9-micron fluorescent latex particles either at rest (n = 9) or while running on a laddermill (n = 9). Oxygen consumption, which was used to estimate minute ventilation, was continuously monitored. Three animals from each group, rest and exercise, were killed at 10 min, 24 h, or 7 days after the exposure. Morphometric techniques were used to determine the number of particles retained in nose and oropharynx (NOSE), trachea and extrapulmonary airways, intrapulmonary conducting airways, respiratory bronchioles, alveolar ducts (AD), and alveoli (ALV). At 10 min, total particle retention increased linearly as a function of O2 consumption (slope = 1.4 +/- 0.3 x 10(6) particles.ml-1.g-1.h-1, P less than 0.015). Exercised hamsters retained 4.4 times more total particles in their NOSE than rested hamsters, but parenchymal retention (AD + ALV) was unaffected. After 7 days, 95% of the particles were cleared from the NOSE, 80% from the trachea and extrapulmonary airways, 44% from intrapulmonary conducting airways and respiratory bronchioles, and 16% from AD and ALV. There was evidence of particle redistribution from AD to ALV during the 1st day. We conclude that exercise enhances the deposition of 0.9-micron particles in the upper respiratory tract but not in the parenchyma. Subsequently, the deposited particles are cleared at varying rates depending on the lung compartment.

Entities:  

Mesh:

Substances:

Year:  1991        PMID: 2032979     DOI: 10.1152/jappl.1991.70.3.1137

Source DB:  PubMed          Journal:  J Appl Physiol (1985)        ISSN: 0161-7567


  8 in total

Review 1.  Particle transport and deposition: basic physics of particle kinetics.

Authors:  Akira Tsuda; Frank S Henry; James P Butler
Journal:  Compr Physiol       Date:  2013-10       Impact factor: 9.090

2.  Effect of detergent on alveolar particle clearance due to large tidal ventilation.

Authors:  J John; P Wollmer; M Dahlbäck; B Jonson
Journal:  Thorax       Date:  1994-02       Impact factor: 9.139

3.  Ventilation/Perfusion Relationships and Gas Exchange: Measurement Approaches.

Authors:  Susan R Hopkins
Journal:  Compr Physiol       Date:  2020-07-08       Impact factor: 9.090

Review 4.  Microscale imaging of cilia-driven fluid flow.

Authors:  Brendan K Huang; Michael A Choma
Journal:  Cell Mol Life Sci       Date:  2014-11-23       Impact factor: 9.261

Review 5.  One (sub-)acinus for all: Fate of inhaled aerosols in heterogeneous pulmonary acinar structures.

Authors:  Philipp Hofemeier; Kenishiro Koshiyama; Shigeo Wada; Josué Sznitman
Journal:  Eur J Pharm Sci       Date:  2017-09-24       Impact factor: 4.384

6.  Concentrated ambient air particles induce vasoconstriction of small pulmonary arteries in rats.

Authors:  Joao R F Batalha; Paulo H N Saldiva; Robert W Clarke; Brent A Coull; Rebecca C Stearns; Joy Lawrence; G G Krishna Murthy; Petros Koutrakis; John J Godleski
Journal:  Environ Health Perspect       Date:  2002-12       Impact factor: 9.031

7.  Particle dynamics and deposition in true-scale pulmonary acinar models.

Authors:  Rami Fishler; Philipp Hofemeier; Yael Etzion; Yael Dubowski; Josué Sznitman
Journal:  Sci Rep       Date:  2015-09-11       Impact factor: 4.379

8.  The role of anisotropic expansion for pulmonary acinar aerosol deposition.

Authors:  Philipp Hofemeier; Josué Sznitman
Journal:  J Biomech       Date:  2016-08-31       Impact factor: 2.712

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.