Literature DB >> 20309648

Release of metal ions from orthodontic appliances by in vitro studies: a systematic literature review.

Marcin Mikulewicz1, Katarzyna Chojnacka.   

Abstract

In the present work, a systematic literature review on release of metal ions from orthodontic appliances under in vitro conditions is described. Detailed and schematic analysis of used materials and applied methods (immersion media, incubation time, temperature, and analytical techniques) is provided. The PubMed search identified 40 studies, among which eight met the selection criteria. One additional study was included in the review. All the authors agreed that the doses of released metal ions were far below the toxic level and the dietary intake. Although the concentrations of metal ions in immersion media greatly differed, the general conclusions were coherent. It must be underlined that the main disadvantage of in vitro tests was that the experimental setup did not reflect in vivo conditions, e.g., the presence of biofilm, which grows on the surface of the materials in oral cavity. The presence and activity of microflora to a large extent is responsible for the process of corrosion, in particular, biodeterioration. The further scheme of in vitro research should incorporate changeable conditions of oral cavity environment (pH, dynamic conditions-saliva flow) and the presence of microbiological flora (microbiological attack) in the experimental design and, first of all, the real proportions of appliance elements.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20309648     DOI: 10.1007/s12011-010-8670-9

Source DB:  PubMed          Journal:  Biol Trace Elem Res        ISSN: 0163-4984            Impact factor:   3.738


  17 in total

1.  Release of metal ions from orthodontic appliances: an in vitro study.

Authors:  Marcin Mikulewicz; Katarzyna Chojnacka; Barbara Woźniak; Patrycja Downarowicz
Journal:  Biol Trace Elem Res       Date:  2011-10-20       Impact factor: 3.738

2.  Galvanic coupling of steel and gold alloy lingual brackets with orthodontic wires: Is corrosion a concern?

Authors:  Georgios Polychronis; Youssef S Al Jabbari; Theodore Eliades; Spiros Zinelis
Journal:  Angle Orthod       Date:  2018-03-06       Impact factor: 2.079

3.  Cytotoxic evaluation of two orthodontic silver solder materials on human periodontal ligament fibroblast cells and the effects of antioxidant and antiapoptotic reagents.

Authors:  Ghada Nimeri; Joseph Curry; David Berzins; Dawei Liu; Bhoomika Ahuja; Douglas Lobner
Journal:  Angle Orthod       Date:  2021-05-01       Impact factor: 2.079

4.  Effect of fluoride agents on surface characteristics of NiTi wires. An ex vivo investigation.

Authors:  Prasad Chitra; G S Prashantha; Arun Rao
Journal:  J Oral Biol Craniofac Res       Date:  2020-08-05

5.  Biomonitorization of metal ions in the serum of Iranian patients treated with fixed orthodontic appliances in comparison with controls in eastern Iran.

Authors:  Mahdjoube Goldani Moghadam; Reyhane Hoshyar; Marcin Mikulewicz; Katarzyna Chojnacka; Geir Bjørklund; Joeri J Pen; Nammam Ali Azadi; Maghdad Pirsaheb; Meysam Dashtaki; Borhan Mansouri
Journal:  Environ Sci Pollut Res Int       Date:  2019-09-14       Impact factor: 4.223

Review 6.  Cytocompatibility of medical biomaterials containing nickel by osteoblasts: a systematic literature review.

Authors:  Marcin Mikulewicz; Katarzyna Chojnacka
Journal:  Biol Trace Elem Res       Date:  2010-08-12       Impact factor: 3.738

7.  An evaluation of two types of nickel-titanium wires in terms of micromorphology and nickel ions' release following oral environment exposure.

Authors:  Abdul Razzak A Ghazal; Mohammad Y Hajeer; Rabab Al-Sabbagh; Ibrahim Alghoraibi; Ahmad Aldiry
Journal:  Prog Orthod       Date:  2015-05-20       Impact factor: 2.750

8.  Virulence modulation of Streptococcus mutans biofilms by metal ions released from orthodontic appliances.

Authors:  Alinne Ulbrich Mores Rymovicz; Maiara Medeiros Ronsani; Ana Maria Trindade Grégio; Odilon Guariza Guariza-Filho; Orlando Tanaka; Edvaldo Antonio Ribeiro Rosa
Journal:  Angle Orthod       Date:  2013-04-15       Impact factor: 2.079

9.  Release of metal ions from fixed orthodontic appliance: an in vitro study in continuous flow system.

Authors:  Marcin Mikulewicz; Katarzyna Chojnacka; Paulina Wołowiec
Journal:  Angle Orthod       Date:  2013-03-11       Impact factor: 2.079

10.  Metallurgical and electrochemical characterization of contemporary silver-based soldering alloys.

Authors:  Argyro Ntasi; Youssef Al Jabbari; Wolf Dieter Mueller; George Eliades; Spiros Zinelis
Journal:  Angle Orthod       Date:  2013-11-07       Impact factor: 2.079

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.