Literature DB >> 20307411

Second insulin pump safety meeting: summary report.

Yi Zhang1, Paul L Jones, David C Klonoff.   

Abstract

Diabetes Technology Society facilitated a second meeting of insulin pump experts at Mills-Peninsula Health Services, San Mateo, California on November 4, 2009, at the request of the Food and Drug Administration, Center for Devices and Radiological Health, Office of Science and Engineering Laboratories. The first such meeting was held in Bethesda, Maryland, on November 12, 2008. The group of physicians, nurses, diabetes educators, and engineers from across the United States discussed safety issues in insulin pump therapy and recommended adjustments to current insulin pump design and use to enhance overall safety. The meeting discussed safety issues in the context of pump operation; software; hardware; physical structure; electrical, biological, and chemical considerations; use; and environment from engineering, medical, nursing, and pump/user perspectives. There was consensus among meeting participants that insulin pump designs have made great progress in improving the quality of life of people with diabetes, but much more remains to be done. (c) 2010 Diabetes Technology Society.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20307411      PMCID: PMC2864186          DOI: 10.1177/193229681000400232

Source DB:  PubMed          Journal:  J Diabetes Sci Technol        ISSN: 1932-2968


  2 in total

1.  Siphon effects on continuous subcutaneous insulin infusion pump delivery performance.

Authors:  Howard C Zisser; Wendy Bevier; Eyal Dassau; Lois Jovanovic
Journal:  J Diabetes Sci Technol       Date:  2010-01-01

2.  Insulin pump safety meeting: summary report.

Authors:  David C Klonoff; Juliet S Reyes
Journal:  J Diabetes Sci Technol       Date:  2009-03-01
  2 in total
  7 in total

1.  Evaluation of Intradermal and Subcutaneous Infusion Set Performance Under 24-Hour Basal and Bolus Conditions.

Authors:  Elaine McVey; Steven Keith; Joshua K Herr; Diane Sutter; Ronald J Pettis
Journal:  J Diabetes Sci Technol       Date:  2015-08-27

2.  Multicenter user evaluation of ACCU-CHEK® Combo, an integrated system for continuous subcutaneous insulin infusion.

Authors:  David Kerr; Roel P L M Hoogma; Andreas Buhr; Bettina Petersen; Fred E M G Storms
Journal:  J Diabetes Sci Technol       Date:  2010-11-01

Review 3.  An Overview of Safety Issues on Use of Insulin Pumps and Continuous Glucose Monitoring Systems in the Hospital.

Authors:  Bithika Thompson; Melinda Leighton; Mary Korytkowski; Curtiss B Cook
Journal:  Curr Diab Rep       Date:  2018-08-17       Impact factor: 4.810

Review 4.  A review of the security of insulin pump infusion systems.

Authors:  Nathanael Paul; Tadayoshi Kohno; David C Klonoff
Journal:  J Diabetes Sci Technol       Date:  2011-11-01

5.  A hazard analysis for a generic insulin infusion pump.

Authors:  Yi Zhang; Paul L Jones; Raoul Jetley
Journal:  J Diabetes Sci Technol       Date:  2010-03-01

6.  Robust fault detection system for insulin pump therapy using continuous glucose monitoring.

Authors:  Pau Herrero; Remei Calm; Josep Vehí; Joaquim Armengol; Pantelis Georgiou; Nick Oliver; Christofer Tomazou
Journal:  J Diabetes Sci Technol       Date:  2012-09-01

7.  Pediatric use of insulin pump technology: a retrospective study of adverse events in children ages 1-12 years.

Authors:  Judith U Cope; Joy H Samuels-Reid; Audrey E Morrison
Journal:  J Diabetes Sci Technol       Date:  2012-09-01
  7 in total