What makes tight glycemic control tight? The impact of variability and nutrition in two clinical studies.

Fatanah Suhaimi1, Aaron Le Compte, Jean-Charles Preiser, Geoffrey M Shaw, Paul Massion, Regis Radermecker, Christopher G Pretty, Jessica Lin, Thomas Desaive, J Geoffrey Chase.   

Abstract

INTRODUCTION: Tight glycemic control (TGC) remains controversial while successful, consistent, and effective protocols remain elusive. This research analyzes data from two TGC trials for root causes of the differences achieved in control and thus potentially in glycemic and other outcomes. The goal is to uncover aspects of successful TGC and delineate the impact of differences in cohorts.
METHODS: A retrospective analysis was conducted using records from a 211-patient subset of the GluControl trial taken in Liege, Belgium, and 393 patients from Specialized Relative Insulin Nutrition Titration (SPRINT) in New Zealand. Specialized Relative Insulin Nutrition Titration targeted 4.0-6.0 mmol/liter, similar to the GluControl A (N = 142) target of 4.4-6.1 mmol/liter. The GluControl B (N = 69) target was 7.8-10.0 mmol/liter. Cohorts were matched by Acute Physiology and Chronic Health Evaluation II score and percentage males (p > .35); however, the GluControl cohort was slightly older (p = .011). Overall cohort and per-patient comparisons (median, interquartile range) are shown for (a) glycemic levels achieved, (b) nutrition from carbohydrate (all sources), and (c) insulin dosing for this analysis. Intra- and interpatient variability were examined using clinically validated model-based insulin sensitivity metric and its hour-to-hour variation.
RESULTS: Cohort blood glucose were as follows: SPRINT, 5.7 (5.0-6.6) mmol/liter; GluControl A, 6.3 (5.3-7.6) mmol/liter; and GluControl B, 8.2 (6.9-9.4) mmol/liter. Insulin dosing was 3.0 (1.0-3.0), 1.5 (0.5-3), and 0.7 (0.0-1.7) U/h, respectively. Nutrition from carbohydrate (all sources) was 435.5 (259.2-539.1), 311.0 (0.0-933.1), and 622.1 (103.7-1036.8) kcal/day, respectively. Median per-patient results for blood glucose were 5.8 (5.3-6.4), 6.4 (5.9-6.9), and 8.3 (7.6-8.8) mmol/liter. Insulin doses were 3.0 (2.0-3.0), 1.5 (0.8-2.0), and 0.5 (0.0-1.0) U/h. Carbohydrate administration was 383.6 (207.4-497.7), 103.7 (0.0-829.4), and 207.4 (0.0-725.8) kcal/day. Overall, SPRINT gave approximately 2x more insulin with a 3-4x narrower, but generally non-zero, range of nutritional input to achieve equally TGC with less hypoglycemia. Specialized Relative Insulin Nutrition Titration had much less hypoglycemia (<2.2 mmol/liter), with 2% of patients, compared to GluControl A (7.7%) and GluControl B (2.9%), indicating much lower variability, with similar results for glucose levels <3.0 mmol/liter. Specialized Relative Insulin Nutrition Titration also had less hyperglycemia (>8.0 mmol/liter) than groups A and B. GluControl patients (A+B) had a approximately 2x wider range of insulin sensitivity than SPRINT. Hour-to-hour variation was similar. Hence GluControl had greater interpatient variability but similar intrapatient variability.
CONCLUSION: Protocols that dose insulin blind to carbohydrate administration can suffer greater outcome glycemic variability, even if average cohort glycemic targets are met. While the cohorts varied significantly in model-assessed insulin resistance, their variability was similar. Such significant intra- and interpatient variability is a further significant cause and marker of glycemic variability in TGC. The results strongly recommended that TGC protocols be explicitly designed to account for significant intra- and interpatient variability in insulin resistance, as well as specifying or having knowledge of carbohydrate administration to minimize variability in glycemic outcomes across diverse cohorts and/or centers. (c) 2010 Diabetes Technology Society.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20307388      PMCID: PMC2864163          DOI: 10.1177/193229681000400208

Source DB:  PubMed          Journal:  J Diabetes Sci Technol        ISSN: 1932-2968


  46 in total

1.  Dose-response characteristics of insulin action on glucose metabolism: a non-steady-state approach.

Authors:  A Natali; A Gastaldelli; S Camastra; A M Sironi; E Toschi; A Masoni; E Ferrannini; A Mari
Journal:  Am J Physiol Endocrinol Metab       Date:  2000-05       Impact factor: 4.310

2.  Improved outcome with aggressive treatment of hyperglycemia: hype or hope?

Authors:  Michael N Diringer
Journal:  Neurology       Date:  2005-04-26       Impact factor: 9.910

3.  Tight glycaemic control: a survey of intensive care practice in the Netherlands.

Authors:  Marcus J Schultz; Peter E Spronk; Hazra S Moeniralam
Journal:  Intensive Care Med       Date:  2006-02-25       Impact factor: 17.440

4.  Predisposing factors for hypoglycemia in the intensive care unit.

Authors:  Titia M Vriesendorp; Susanne van Santen; J Hans DeVries; Evert de Jonge; Frits R Rosendaal; Marcus J Schultz; Joost B L Hoekstra
Journal:  Crit Care Med       Date:  2006-01       Impact factor: 7.598

Review 5.  Alterations in fuel metabolism in critical illness: hyperglycaemia.

Authors:  B A Mizock
Journal:  Best Pract Res Clin Endocrinol Metab       Date:  2001-12       Impact factor: 4.690

6.  Integral-based parameter identification for long-term dynamic verification of a glucose-insulin system model.

Authors:  Christopher E Hann; J Geoffrey Chase; Jessica Lin; Thomas Lotz; Carmen V Doran; Geoffrey M Shaw
Journal:  Comput Methods Programs Biomed       Date:  2005-03       Impact factor: 5.428

7.  The effect of insulin dose on the measurement of insulin sensitivity by the minimal model technique. Evidence for saturable insulin transport in humans.

Authors:  R L Prigeon; M E Røder; D Porte; S E Kahn
Journal:  J Clin Invest       Date:  1996-01-15       Impact factor: 14.808

8.  Targeted glycemic reduction in critical care using closed-loop control.

Authors:  J Geoffrey Chase; Geoffrey M Shaw; Jessica Lin; Carmen V Doran; Chris Hann; Thomas Lotz; Graeme C Wake; Bob Broughton
Journal:  Diabetes Technol Ther       Date:  2005-04       Impact factor: 6.118

Review 9.  Clinical experience with tight glucose control by intensive insulin therapy.

Authors:  Jean-Charles Preiser; Philippe Devos
Journal:  Crit Care Med       Date:  2007-09       Impact factor: 7.598

10.  Association between hyperglycemia and increased hospital mortality in a heterogeneous population of critically ill patients.

Authors:  James Stephen Krinsley
Journal:  Mayo Clin Proc       Date:  2003-12       Impact factor: 7.616

View more
  17 in total

1.  Stochastic targeted (STAR) glycemic control: design, safety, and performance.

Authors:  Alicia Evans; Aaron Le Compte; Chia-Siong Tan; Logan Ward; James Steel; Christopher G Pretty; Sophie Penning; Fatanah Suhaimi; Geoffrey M Shaw; Thomas Desaive; J Geoffrey Chase
Journal:  J Diabetes Sci Technol       Date:  2012-01-01

2.  Autoregressive Modeling of Drift and Random Error to Characterize a Continuous Intravascular Glucose Monitoring Sensor.

Authors:  Tony Zhou; Jennifer L Dickson; J Geoffrey Chase
Journal:  J Diabetes Sci Technol       Date:  2017-07-14

3.  Pilot study of the SPRINT glycemic control protocol in a Hungarian medical intensive care unit.

Authors:  Balazs Benyo; Attila Illyés; Noémi Szabó Némedi; Aaron J Le Compte; Attila Havas; Levente Kovacs; Liam Fisk; Geoffrey M Shaw; J Geoffrey Chase
Journal:  J Diabetes Sci Technol       Date:  2012-11-01

4.  Organ failure and tight glycemic control in the SPRINT study.

Authors:  J Geoffrey Chase; Christopher G Pretty; Leesa Pfeifer; Geoffrey M Shaw; Jean-Charles Preiser; Aaron J Le Compte; Jessica Lin; Darren Hewett; Katherine T Moorhead; Thomas Desaive
Journal:  Crit Care       Date:  2010-08-12       Impact factor: 9.097

5.  Continuous Glucose Monitoring Measures Can Be Used for Glycemic Control in the ICU: An In-Silico Study.

Authors:  Tony Zhou; Jennifer L Dickson; Geoffrey M Shaw; J Geoffrey Chase
Journal:  J Diabetes Sci Technol       Date:  2017-11-06

6.  Variability of insulin sensitivity during the first 4 days of critical illness: implications for tight glycemic control.

Authors:  Christopher G Pretty; Aaron J Le Compte; J Geoffrey Chase; Geoffrey M Shaw; Jean-Charles Preiser; Sophie Penning; Thomas Desaive
Journal:  Ann Intensive Care       Date:  2012-06-15       Impact factor: 6.925

7.  Daily evolution of insulin sensitivity variability with respect to diagnosis in the critically ill.

Authors:  Tamás Ferenci; Balázs Benyó; Levente Kovács; Liam Fisk; Geoffrey M Shaw; J Geoffrey Chase
Journal:  PLoS One       Date:  2013-02-21       Impact factor: 3.240

8.  Validation of a model-based virtual trials method for tight glycemic control in intensive care.

Authors:  J Geoffrey Chase; Fatanah Suhaimi; Sophie Penning; Jean-Charles Preiser; Aaron J Le Compte; Jessica Lin; Christopher G Pretty; Geoffrey M Shaw; Katherine T Moorhead; Thomas Desaive
Journal:  Biomed Eng Online       Date:  2010-12-14       Impact factor: 2.819

9.  Physiological modeling, tight glycemic control, and the ICU clinician: what are models and how can they affect practice?

Authors:  J Geoffrey Chase; Aaron J Le Compte; J-C Preiser; Geoffrey M Shaw; Sophie Penning; Thomas Desaive
Journal:  Ann Intensive Care       Date:  2011-05-05       Impact factor: 6.925

10.  Pilot proof of concept clinical trials of Stochastic Targeted (STAR) glycemic control.

Authors:  Alicia Evans; Geoffrey M Shaw; Aaron Le Compte; Chia-Siong Tan; Logan Ward; James Steel; Christopher G Pretty; Leesa Pfeifer; Sophie Penning; Fatanah Suhaimi; Matthew Signal; Thomas Desaive; J Geoffrey Chase
Journal:  Ann Intensive Care       Date:  2011-09-19       Impact factor: 6.925

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.