Literature DB >> 20304496

[Vertebroplasty: 10 years clinical and radiological follow-up].

J Franc1, P Lehmann, G Saliou, P Monet, E-M Kocheida, E Daguet, A Laurent, D Legars, H Deramond.   

Abstract

OBJECTIVES: Ten years follow-up of the first patients treated with percutaneous vertebroplasty. PATIENT AND METHODS: Eighteen patients were retrospectively reviewed having undergone vertebroplasty in our centre between 1989 and 1998. Eight were treated for angioma, eight for osteoporotic compression and two followed for myeloma. They all underwent clinical and radiological evaluation in 2007 (standard X-rays, CT scan and MRI). These examinations were compared to prior baseline pre- and post-therapeutic images.
RESULTS: Radiological characteristic of cement remained unchanged in the long term and there was no modification of anatomical structures in contact with it. Even if the distribution of cement was asymmetrical there was no fracture of the treated vertebras at distance. Degenerative changes of discs facing the vertebroplasty were not more pronounced than for distant discs. We found no significant signal or density anomaly of disc in contact direct with cement. 38.8 % of the patients presented new fractures (n=30). Seventy percent of the fractures were multiple and contiguous. In the long term, all patients reported improvement of pain after the procedure.
CONCLUSION: In our series, we found a good stability of treatment over time. This study shows the long-term safety of percutaneous acrylic vertebroplasty, in particular harmlessness of cement for bone and discs in contact.
Copyright © 2010 Elsevier Masson SAS. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20304496     DOI: 10.1016/j.neurad.2009.10.004

Source DB:  PubMed          Journal:  J Neuroradiol        ISSN: 0150-9861            Impact factor:   3.447


  5 in total

Review 1.  Health economic aspects of vertebral augmentation procedures.

Authors:  F Borgström; D P Beall; S Berven; S Boonen; S Christie; D F Kallmes; J A Kanis; G Olafsson; A J Singer; K Åkesson
Journal:  Osteoporos Int       Date:  2014-11-08       Impact factor: 4.507

2.  Facet joint injections as a means of reducing the need for vertebroplasty in insufficiency fractures of the spine.

Authors:  David J Wilson; Sara Owen; Rufus A Corkill
Journal:  Eur Radiol       Date:  2011-04-13       Impact factor: 5.315

3.  [Osteoporotic vertebral body fractures of the thoracolumbar spine. Diagnostics and therapeutic strategies].

Authors:  C Josten; C Schmidt; U Spiegl
Journal:  Chirurg       Date:  2012-10       Impact factor: 0.955

4.  Combined local treatments for vertebral metastases with limited epidural extension.

Authors:  Khaled Madani; Arash Najafi; Angela Boticella; Charles Roux; Lambros Tselikas; Alexandre Delpla; Marc Al Ahmar; Thierry de Baere; Frédéric Deschamps
Journal:  Support Care Cancer       Date:  2021-07-21       Impact factor: 3.603

5.  High-viscosity bone cement for vertebral compression fractures: a prospective study on intravertebral diffusion and leakage of bone cement.

Authors:  Meiyong Wang; Qunhua Jin
Journal:  BMC Musculoskelet Disord       Date:  2020-09-02       Impact factor: 2.362

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.