Literature DB >> 20298891

A low-cost method for determination of calcium carbonate in cement by membraneless vaporization with capacitively coupled contactless conductivity detection.

Kamonthip Sereenonchai1, Saowapak Teerasong, Sumonmarn Chan-Eam, Phoonthawee Saetear, Nathawut Choengchan, Kanchana Uraisin, Natchanon Amornthammarong, Shoji Motomizu, Duangjai Nacapricha.   

Abstract

This work presents a flow analysis method for direct quantitation of calcium carbonate in cement without pretreatment of the sample. The method is based on online vaporization of CO(2) gas following acidification of the sample inside a small chamber that has a flow of acceptor solution passing around it. Solubilization of the CO(2) gas into the acceptor stream changes the conductivity of the acceptor solution causing an increase of signal at the capacitively coupled contactless conductivity detection (C(4)D) placed at the outlet of the vaporization chamber. This chamber is an adaption from previous work reported on 'membraneless vaporization' (MBL-VP). The method can be used in the quality control of production of mixed cement. These cement materials usually have calcium carbonate contents at high concentration range (e.g., 33-99% (w/w) CaCO(3)). Analysis of samples by this method is direct and convenient as it requires no sample pretreatment. The method is low-cost with satisfactory accuracy and acceptable precision.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20298891     DOI: 10.1016/j.talanta.2010.01.057

Source DB:  PubMed          Journal:  Talanta        ISSN: 0039-9140            Impact factor:   6.057


  4 in total

1.  A disposable blood cyanide sensor.

Authors:  Yong Tian; Purnendu K Dasgupta; Sari B Mahon; Jian Ma; Matthew Brenner; Jian-Hua Wang; Gerry R Boss
Journal:  Anal Chim Acta       Date:  2013-02-01       Impact factor: 6.558

2.  Novel Approach to Sample Preconcentration by Solvent Evaporation in Flow Analysis.

Authors:  Justyna Paluch; Joanna Kozak; Marcin Wieczorek; Michał Woźniakiewicz; Małgorzata Gołąb; Ewelina Półtorak; Sławomir Kalinowski; Paweł Kościelniak
Journal:  Molecules       Date:  2020-04-18       Impact factor: 4.411

3.  Home-Made Membraneless Vaporization Gas-Liquid Separator for Colorimetric Determination of Ethanol in Alcoholic Beverages.

Authors:  Vanpaseuth Phouthavong; Hayato Inoue; Kesiny Phomkeona; Vanseng Chounlamany
Journal:  J Anal Methods Chem       Date:  2022-03-31       Impact factor: 2.193

4.  Dual-Purpose Photometric-Conductivity Detector for Simultaneous and Sequential Measurements in Flow Analysis.

Authors:  Thitirat Mantim; Korbua Chaisiwamongkhol; Kanchana Uraisin; Peter C Hauser; Prapin Wilairat; Duangjai Nacapricha
Journal:  Molecules       Date:  2020-05-13       Impact factor: 4.411

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.