Loosening of cementless femoral stems: a biomechanical analysis of immediate fixation with loading vertical, femur horizontal.

T W Phillips1, L T Nguyen, S D Munro.   

Abstract

Large joint implants must have immediate fixation to be successful. Unfortunately, the magnitude and consistency of achieving this remains largely unknown. For cementless femoral components it is being increasingly appreciated that torsional loading as occurs during stair climbing or rising from a chair leads to loosening and thigh pain in some cases. A biomechanical test was developed to evaluate fixation in this position. Twelve pairs of human cadaveric femora were press-fit with an AML stem. Each femur was secured in a horizontal position, and the prosthetic head cyclically loaded in a vertically downward direction. The offset of the prosthetic head resulted in a combined torsional and compressive load being applied to the stem within the proximal femur. Loosening was found to consistently occur and rapidly accelerate when the head subsided more than 0.2 mm during 100 cycles. For the AML stem, loosening developed at loads from 62 to 171% of body weight and after as few as 800 cycles. This is within the physiologic range of normal daily activities as measured by others with instrumented prostheses. This poses a challenge to the ability of press-fit stems to tolerate torsional loads in vivo. Patients with a cementless prosthesis should be protected from torsional loading until porous ingrowth and/or bone remodelling have had time to occur. Testing the same stem in paired femora demonstrated no right vs left difference (p greater than 0.6).

Entities:  

Mesh:

Substances:

Year:  1991        PMID: 2026632     DOI: 10.1016/0021-9290(91)90324-g

Source DB:  PubMed          Journal:  J Biomech        ISSN: 0021-9290            Impact factor:   2.712


  9 in total

1.  Hip painful prosthesis: surgical view.

Authors:  Antonio Spinarelli; Vittorio Patella; Vito Conserva; Giovanni Vicenti; Vito Pesce; Silvio Patella
Journal:  Clin Cases Miner Bone Metab       Date:  2011-05

2.  The effect of abductor muscle and anterior-posterior hip contact load simulation on the in-vitro primary stability of a cementless hip stem.

Authors:  Youngbae Park; Carolyne Albert; Yong-San Yoon; Göran Fernlund; Hanspeter Frei; Thomas R Oxland
Journal:  J Orthop Surg Res       Date:  2010-06-24       Impact factor: 2.359

3.  Analysis of hip joint loading during walking with different shoe types using instrumented total hip prostheses.

Authors:  Y Palmowski; S Popović; D Kosack; P Damm
Journal:  Sci Rep       Date:  2021-05-12       Impact factor: 4.379

4.  Stem diameter and rotational stability in revision total hip arthroplasty: a biomechanical analysis.

Authors:  R Michael Meneghini; Nadim J Hallab; Richard A Berger; Joshua J Jacobs; Wayne G Paprosky; Aaron G Rosenberg
Journal:  J Orthop Surg Res       Date:  2006-10-02       Impact factor: 2.359

5.  Unilateral total hip replacement patients with symptomatic leg length inequality have abnormal hip biomechanics during walking.

Authors:  Junyan Li; Anthony B McWilliams; Zhongmin Jin; John Fisher; Martin H Stone; Anthony C Redmond; Todd D Stewart
Journal:  Clin Biomech (Bristol, Avon)       Date:  2015-02-28       Impact factor: 2.063

6.  In vivo analysis of hip joint loading on Nordic walking novices.

Authors:  Yannick Palmowski; Srdan Popovic; Simone G Schuster; Sebastian Hardt; Philipp Damm
Journal:  J Orthop Surg Res       Date:  2021-10-14       Impact factor: 2.359

7.  Assessment of the primary rotational stability of uncemented hip stems using an analytical model: comparison with finite element analyses.

Authors:  Maria E Zeman; Nicolas Sauwen; Luc Labey; Michiel Mulier; Georges Van der Perre; Siegfried V N Jaecques
Journal:  J Orthop Surg Res       Date:  2008-09-25       Impact factor: 2.359

8.  Comparison of the plantar pressure distributions at different degrees of tilting: a preliminary report.

Authors:  Sung-Min Son; Jun-Ho Lee; Yong-Jun Cha
Journal:  J Phys Ther Sci       Date:  2014-03-25

9.  Correlation between the bone mineral density and stress on femur around a Duetto SI stem.

Authors:  Rina Sakai; Takeaki Yamamoto; Katsufumi Uchiyama; Kentaro Uchida; Masaki Nakao; Kiyoshi Mabuchi
Journal:  ScientificWorldJournal       Date:  2014-06-26
  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.