Literature DB >> 20236780

Accuracy and reliability of facial soft tissue depth measurements using cone beam computer tomography.

Zacharias Fourie1, Janalt Damstra, Peter O Gerrits, Yijin Ren.   

Abstract

It is important to have accurate and reliable measurements of soft tissue thickness for specific landmarks of the face and scalp when producing a facial reconstruction. In the past several methods have been created to measure facial soft tissue thickness (FSTT) in cadavers and in the living. The conventional spiral CT is mostly used to determine the FSTT but is associated with high radiation doses. The cone beam CT (CBCT) is a relatively new computer tomography system that focuses on head and neck regions and has much lower radiation doses. The aim of this study is to determine the accuracy and reliability of CBCT scans to measure the soft tissue thicknesses of the face. Seven cadaver heads were used. Eleven soft tissue landmarks were identified on each head and a punch hole was made on each landmark using a dermal biopsy punch. The seven cadaver heads were scanned in the CBCT with 0.3 and 0.4mm resolution. The FSTT at the 11 different sites (soft tissue landmarks) were measured using SimPlant-ortho volumetric software. These measurements were compared to the physical measurements. Statistical analysis for the reliability was done by means of the interclass coefficient (ICC) and the accuracy by means of the absolute error (AE) and absolute percentage error (APE). The intra-observer (0.976-0.999) and inter-observer (0.982-0.997) correlations of the CBCT and physical measurements were very high. There was no clinical significant difference between the measurements made on the CBCT images and the physical measurements. Increasing the voxel size from 0.4 to 0.3mm resulted in a slight increase of accuracy. Cone beam CT images of the face using routine scanning protocols are reliable for measuring soft tissue thickness in the facial region and give a good representation of the facial soft tissues. For more accurate data collection the 0.3mm voxel size should be considered. (c) 2010 Elsevier Ireland Ltd. All rights reserved.

Entities:  

Mesh:

Year:  2010        PMID: 20236780     DOI: 10.1016/j.forsciint.2010.02.018

Source DB:  PubMed          Journal:  Forensic Sci Int        ISSN: 0379-0738            Impact factor:   2.395


  18 in total

1.  Accuracy of linear intraoral measurements using cone beam CT and multidetector CT: a tale of two CTs.

Authors:  R Patcas; G Markic; L Müller; O Ullrich; T Peltomäki; C J Kellenberger; C A Karlo
Journal:  Dentomaxillofac Radiol       Date:  2012-05-03       Impact factor: 2.419

2.  Post-processing open-source software for the CBCT monitoring of periapical lesions healing following endodontic treatment: technical report of two cases.

Authors:  Eduardo M Villoria; Antônio R Lenzi; Rodrigo V Soares; Bernardo Q Souki; Asgeir Sigurdsson; Alexandre P Marques; Sandra R Fidel
Journal:  Dentomaxillofac Radiol       Date:  2016-12-12       Impact factor: 2.419

3.  Lip morphology estimation models based on three-dimensional images in a modern adult population from China.

Authors:  Jia-Min Zhao; Ling-Ling Ji; Meng-Qi Han; Qing-Nan Mou; Guang Chu; Teng Chen; Shao-Yi Du; Yu-Xia Hou; Yu-Cheng Guo
Journal:  Int J Legal Med       Date:  2021-03-24       Impact factor: 2.686

4.  Using Computed Tomography (CT) Data to Build 3D Resources for Forensic Craniofacial Identification.

Authors:  Terrie Simmons-Ehrhardt; Catyana R S Falsetti; Anthony B Falsetti
Journal:  Adv Exp Med Biol       Date:  2021       Impact factor: 2.622

5.  In vivo facial soft tissue depths of a modern adult population from Germany.

Authors:  Nicolle Thiemann; Volker Keil; Uwe Roy
Journal:  Int J Legal Med       Date:  2017-04-17       Impact factor: 2.686

Review 6.  Impact of voxel size variation on CBCT-based diagnostic outcome in dentistry: a systematic review.

Authors:  Rubens Spin-Neto; Erik Gotfredsen; Ann Wenzel
Journal:  J Digit Imaging       Date:  2013-08       Impact factor: 4.056

7.  A Prospective, Randomized, Double-Blind, Placebo-Controlled Clinical Trial Comparing the Efficacy of Anti-edema Drugs for Edema Control in Orthognathic Surgery Using Digitizer 3-D to Measure Facial Swelling.

Authors:  U Tozzi; V Santillo; G P Tartaro; A Sellitto; G R Gravino; M Santagata
Journal:  J Maxillofac Oral Surg       Date:  2014-09-04

8.  The influence of the segmentation process on 3D measurements from cone beam computed tomography-derived surface models.

Authors:  Willem P Engelbrecht; Zacharias Fourie; Janalt Damstra; Peter O Gerrits; Yijin Ren
Journal:  Clin Oral Investig       Date:  2013-01-31       Impact factor: 3.573

Review 9.  Cone beam computed tomography - know its secrets.

Authors:  Mohan Kumar; Muhammad Shanavas; Ashwin Sidappa; Madhu Kiran
Journal:  J Int Oral Health       Date:  2015-02

10.  The Effectiveness of Saireito, a Traditional Japanese Herbal Medicine, in Reducing Postoperative Edema after Acquired Ptosis Surgery: A Prospective Controlled Trial.

Authors:  Naoki Morimoto; Natsuko Kakudo; Toshihito Mitsui; Atsuyuki Kuro; Yuko Ueda; Masakatsu Hihara; Yoshihito Tanaka; Yujiro Ozaki; Kenji Suzuki; Kenji Kusumoto
Journal:  Evid Based Complement Alternat Med       Date:  2018-06-27       Impact factor: 2.629

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.