The immediately loaded single implant-retained mandibular overdenture: a 36-month prospective study.

Glen Liddelow1, Patrick Henry.   

Abstract

PURPOSE: The aim of this study was to ascertain whether simplifying mandibular overdenture treatment by using single-stage surgery and immediate prosthetic loading of a single implant will achieve acceptable implant success rates, functional improvement, and increased patient satisfaction. As part of this study, the Mk III Branemark implant with an oxidized surface was compared to the classic machined Mk III Branemark implant.
MATERIALS AND METHODS: Thirty-five patients (mean age: 68 years) with problematic mandibular dentures were treated. The primary complaints among the patients referred to the clinic for treatment were poor retention of the mandibular denture, instability, denture sores, and phonetic problems. Initially, patients were placed randomly into the "machined surface" or "oxidized surface" groups. A single implant was placed in the mandibular midline with high initial stability. A ball attachment was placed and the retentive cap incorporated into the existing denture. Reviews took place at 3, 12, and 36 months posttreatment. Clinical assessments, radiographs made with custom film holders, and stability measurements by both manual and resonance frequency analysis methods were recorded. All complications, failures, maintenance, and reasons for dropout were noted. Visual analog scale questionnaires were used to record patient satisfaction (analysis of variance: P < .05).
RESULTS: Three of eight machined-surface implants failed, representing an unacceptably high failure rate (37.5%). The machined surface was therefore discontinued for this study. One machined and two oxidized-surface implants did not achieve sufficient primary stability to be immediately loaded, so they were treated with a two-stage delayed loading protocol. The 25 immediately loaded oxidized-surface implants were all classified as surviving at the 36-month recall. Patient satisfaction was very high with a significant increase in all comfort and functional parameters.
CONCLUSIONS: Within the limitations of this study and research design, it appears that over a 3-year observation period, the immediately loaded single implant-retained mandibular overdenture, using an oxidized-surface implant and the existing prosthesis in a small group of prosthetically maladaptive patients, can provide a beneficial treatment outcome with a minimal financial outlay. Int J Prosthodont 2010;23:13-21.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20234886

Source DB:  PubMed          Journal:  Int J Prosthodont        ISSN: 0893-2174            Impact factor:   1.681


  16 in total

Review 1.  Immediate loading of overdentures: systematic review.

Authors:  Marcelo Coelho Goiato; Lisiane Cristina Bannwart; Aldiéris Alves Pesqueira; Daniela Micheline dos Santos; Marcela Filié Haddad; Murillo Rezende Santos; Paula Uchoa Castilho
Journal:  Oral Maxillofac Surg       Date:  2013-07-05

Review 2.  The single midline implant in the edentulous mandible: a systematic review.

Authors:  Nicole Passia; Matthias Kern
Journal:  Clin Oral Investig       Date:  2014-05-29       Impact factor: 3.573

3.  Pain and discomfort following immediate and delayed loading by overdentures in the single mandibular implant study (SMIS).

Authors:  T Mundt; N Passia; W Att; G Heydecke; S Freitag-Wolf; R G Luthardt; S Kappel; I K Konstantinidis; M Stiesch; S Wolfart; M Kern
Journal:  Clin Oral Investig       Date:  2016-08-12       Impact factor: 3.573

4.  Comparison of ridge resorption and patient satisfaction in single implant-supported mandibular overdentures with conventional complete dentures: A randomised pilot study.

Authors:  Subin Km; Dheeraj Kumar Koli; Veena Jain; Gunjan Pruthi; Aditi Nanda
Journal:  J Oral Biol Craniofac Res       Date:  2020-11-25

5.  A prospective study of early loaded single implant-retained mandibular overdentures: preliminary one-year results.

Authors:  Ali M El-Sheikh; Omar F Shihabuddin; Sahar M F Ghoraba
Journal:  Int J Dent       Date:  2012-03-15

Review 6.  WITHDRAWN: Interventions for replacing missing teeth: different types of dental implants.

Authors:  Marco Esposito; Yasmin Ardebili; Helen V Worthington
Journal:  Cochrane Database Syst Rev       Date:  2019-10-10

7.  Cost-effectiveness analysis of the single-implant mandibular overdenture versus conventional complete denture: study protocol for a randomized controlled trial.

Authors:  Túlio Eduardo Nogueira; Shahrokh Esfandiari; Cláudio Rodrigues Leles
Journal:  Trials       Date:  2016-11-04       Impact factor: 2.279

Review 8.  A systematic review and meta-analysis of removable and fixed implant-supported prostheses in edentulous jaws: post-loading implant loss.

Authors:  Jaana-Sophia Kern; Thomas Kern; Stefan Wolfart; Nicole Heussen
Journal:  Clin Oral Implants Res       Date:  2015-02-09       Impact factor: 5.977

9.  Single dental implant retained mandibular complete dentures--influence of the loading protocol: study protocol for a randomized controlled trial.

Authors:  Nicole Passia; Miha Brezavšček; Elfriede Fritzer; Stefanie Kappel; Thomas Kern; Ralph G Luthardt; Nadine Frfr von Maltzahn; Torsten Mundt; Michael Rädel; Axel von Stein-Lausnitz; Matthias Kern
Journal:  Trials       Date:  2014-05-24       Impact factor: 2.279

10.  Single implant supported mandibular overdenture: A literature review.

Authors:  Sudhindra Mahoorkar; Srinidhi Bhat; Radhika Kant
Journal:  J Indian Prosthodont Soc       Date:  2016 Jan-Mar