Literature DB >> 20233507

In vitro and in vivo characterization of novel biodegradable polymers for application as drug-eluting stent coatings.

Nathan A Lockwood1, Robert W Hergenrother, Laura M Patrick, Sean M Stucke, Rob Steendam, Erica Pacheco, Renu Virmani, Frank D Kolodgie, Brad Hubbard.   

Abstract

We have used a series of in vitro and in vivo tests to assess the suitability of two new degradable polymers for application as coatings for drug-eluting stents. The first is a family of urethane-linked multi-block copolymers (MBCP) that comprise blocks of lactide, glycolide, epsilon-caprolactone and/or poly(ethylene glycol) chain-extended with 1,4-butanediisocyanate (SynBiosys polymers). The second is a family of maltodextrin (MD) modified with fatty acid sidechains to yield a hydrophobic polymer (Eureka() SOLO polymers). We coated stainless-steel stents with two representative urethane-linked MBCPs and one hydrophobic MD polymer alone or in combination with the anti-restenotic drug sirolimus. Urethane-linked MBCPs formed uniform coatings on the stent substrates, withstood crimping and expansion on balloon catheters, completely released sirolimus from the coating within 30 days, and degraded within 30-60 days in PBS. The hydrophobic MD polymer formed uniform coatings, exhibited somewhat slower release of sirolimus (approx. 85% within 30 days), degraded within 60 days in PBS when sirolimus was incorporated in the coating, but showed very slow degradation in the absence of drug. We implanted stents coated with urethane-linked MBCPs or hydrophobic MD polymers in a porcine coronary artery model and used histological analysis at 28- and 90-day end-points to assess the biological response to the materials. Measures of stenosis and inflammation for urethane-linked MBCP and hydrophobic MD polymer coatings were not statistically different from bare metal controls at 28 and 90 days, suggesting that the polymers show good vascular biocompatibility. Endothelialization was nearly complete at 28 days and complete at 90 days for all formulations. Urethane-linked MBCP polymer-only and drug-eluting coatings and hydrophobic MD drug-eluting coatings were nearly completely degraded within 90 days in vivo whereas roughly half of hydrophobic MD polymer-only coatings remained after 90 days. Taken together, our in vitro and in vivo results suggest that SynBiosys urethane-linked MBCP and Eureka SOLO hydrophobic MD polymer families possess the physical and chemical properties and vascular biocompatibility necessary for further investigation for use in the next generation of drug-eluting stents.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20233507     DOI: 10.1163/156856209X429175

Source DB:  PubMed          Journal:  J Biomater Sci Polym Ed        ISSN: 0920-5063            Impact factor:   3.517


  5 in total

Review 1.  Restenosis after PCI. Part 2: prevention and therapy.

Authors:  J Wouter Jukema; Tarek A N Ahmed; Jeffrey J W Verschuren; Paul H A Quax
Journal:  Nat Rev Cardiol       Date:  2011-10-11       Impact factor: 32.419

2.  Comparison of sequential drug release in vitro and in vivo.

Authors:  Sharath C Sundararaj; Mohanad Al-Sabbagh; Cheryl L Rabek; Thomas D Dziubla; Mark V Thomas; David A Puleo
Journal:  J Biomed Mater Res B Appl Biomater       Date:  2015-06-25       Impact factor: 3.368

3.  Heparin-Tagged PLA-PEG Copolymer-Encapsulated Biochanin A-Loaded (Mg/Al) LDH Nanoparticles Recommended for Non-Thrombogenic and Anti-Proliferative Stent Coating.

Authors:  Shivakalyani Adepu; Hongrong Luo; Seeram Ramakrishna
Journal:  Int J Mol Sci       Date:  2021-05-21       Impact factor: 5.923

4.  Stents Eluting 6-Mercaptopurine Reduce Neointima Formation and Inflammation while Enhancing Strut Coverage in Rabbits.

Authors:  Matthijs S Ruiter; Claudia M van Tiel; Albert Doornbos; Goran Marinković; Aart C Strang; Nico J M Attevelt; Vivian de Waard; Robbert J de Winter; Rob Steendam; Carlie J M de Vries
Journal:  PLoS One       Date:  2015-09-21       Impact factor: 3.240

5.  Miniaturized self-expanding drug-eluting stent in small coronary arteries: late effectiveness.

Authors:  Flavio Roberto Azevedo de Oliveira; Luiz Alberto Piva E Mattos; Alexandre Abizaid; Andrea S Abizaid; J Ribamar Costa; Ricardo Costa; Rodolfo Staico; Roberto Botelho; J Eduardo Sousa; Amanda Sousa
Journal:  Arq Bras Cardiol       Date:  2013-10-08       Impact factor: 2.000

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.