Literature DB >> 20228975

Evaluation of hard tissue response around wider platform-switched implants.

Roberto Cocchetto1, Tonino Traini, Floriana Caddeo, Renato Celletti.   

Abstract

The use of a narrower-diameter abutment over a larger-diameter implant platform has been shown to decrease peri-implant bone resorption. This technique, known as platform switching, shifts the implant-abutment microgap inward. The aim of this study was to examine whether shifting the microgap further inward by increasing the discrepancy between the implant platform and abutment diameter would result in a decrease in crestal bone loss. Ten patients requiring mandibular or maxillary implant restorations were included in this study. The inclusion criteria called for an alveolar crest thickness of at least 8.0 mm at the implant placement site. Fifteen Certain PREVAIL implants with a body diameter of 5.0 mm, an expanded platform feature with a maximum diameter of 5.8 mm at the collar, and a prosthetic seating surface of 5.0 mm were used in lengths of 8.5, 10.0, 11.5, or 13.0 mm. The implants were connected to 4.1-mm healing abutments in a single-stage protocol. Periapical radiographs taken before and immediately after surgery, 8 weeks after implant placement, immediately after definitive prosthesis insertion, and at 12 and 18 months after loading revealed an average peri-implant bone loss of 0.30 mm. Increasing the discrepancy between the diameter of the implant platform and the restorative abutment may lead to a decrease in the amount of subsequent coronal bone loss.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20228975

Source DB:  PubMed          Journal:  Int J Periodontics Restorative Dent        ISSN: 0198-7569            Impact factor:   1.840


  10 in total

1.  Three-dimensional finite element analysis of platform switched implant.

Authors:  Se-Young Moon; Young-Jun Lim; Myung-Joo Kim; Ho-Beom Kwon
Journal:  J Adv Prosthodont       Date:  2017-02-07       Impact factor: 1.904

2.  Stress distribution in the transitional peri-implant bone in a single implant-supported prosthesis with platform-switching under different angulated loads.

Authors:  Ángel Álvarez-Arenal; Luis Segura-Mori; Ignacio Gonzalez-Gonzalez; Hector DeLlanos-Lanchares; Fernando Sanchez-Lasheras; Joseba Ellacuria-Echevarria
Journal:  Odontology       Date:  2016-03-04       Impact factor: 2.634

3.  Analysis of the intraimplant microflora of two-piece dental implants.

Authors:  Sönke Harder; Rainer Podschun; Livia Grancicova; Christian Mehl; Matthias Kern
Journal:  Clin Oral Investig       Date:  2012-09-08       Impact factor: 3.573

4.  Retrospective Clinical Study of Marginal Bone Level Changes with Two Different Screw-Implant Types: Comparison Between Tissue Level (TE) and Bone Level (BL) Implant.

Authors:  Vinay V Kumar; Keyvan Sagheb; Peer W Kämmerer; Bilal Al-Nawas; Wilfried Wagner
Journal:  J Maxillofac Oral Surg       Date:  2013-06-11

5.  Platform switching on wide-diameter external hex implants: a finite element analysis.

Authors:  Stefano Sivolella; Riccardo Guazzo; Eriberto Bressan; Mario Berengo; Edoardo Stellini
Journal:  J Clin Exp Dent       Date:  2013-04-01

6.  Case presentation of two patients using diagonal platform-switched double implants for maxillary single-first-molar replacement as the alternative of a single-tooth implant.

Authors:  Yasunori Hotta; Koji Ito; Shinichi Komatsu; Takashi Saito
Journal:  Int J Implant Dent       Date:  2015-11-12

7.  Randomized Clinical Investigation of Titanium Implants with and without Platform Switching: Six Months' Radiographic and Clinical Outcome.

Authors:  Roberto Rossi; Diego Capri; Emanuele Risciotti; Paul Zeman
Journal:  Dent J (Basel)       Date:  2015-04-23

8.  Current results and trends in platform switching.

Authors:  Hadi Salimi; Omid Savabi; Farahnaz Nejatidanesh
Journal:  Dent Res J (Isfahan)       Date:  2011-12

Review 9.  Marginal bone loss in relation to platform switching implant insertion depth: An update.

Authors:  Rocío Alonso-González; Amparo Aloy-Prósper; David Peñarrocha-Oltra; M A Peñarrocha-Diago; M Peñarrocha-Diago
Journal:  J Clin Exp Dent       Date:  2012-07-01

10.  Platform switch versus platform match in the posterior mandible – 1-year results of a multicentre randomized clinical trial.

Authors:  Fernando Guerra; Wilfried Wagner; Jörg Wiltfang; Salomão Rocha; Maximilian Moergel; Eleonore Behrens; Pedro Nicolau
Journal:  J Clin Periodontol       Date:  2014-05       Impact factor: 8.728

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.