Literature DB >> 20227079

Numerical simulation of hemodynamics in stented internal carotid aneurysm based on patient-specific model.

Wenyu Fu1, Zhaoyong Gu, Xianlong Meng, Bo Chu, Aike Qiao.   

Abstract

There is still a considerable lack of quantitative information concerning the effects of stent structures on blood flow in an aneurismal cavity. In this paper, five virtual stents with different structures and wire cross-sections were designed for incorporation into the same patient-specific aneurysm model. Computational fluid dynamics simulations were performed so as to study how these five types of stents modified hemodynamic parameters. Numerical results demonstrated that the mean flow rate in the aneurismal cavity decreased the most in the model that used a stent with a rectangular wire cross-section, and that the wall shear stresses at the dome and neck of the aneurysm decreased more in models that used a stent with a circular wire cross-section or a spiral stent with a rectangular wire cross-section compared to other models. In addition, the wall pressure on the aneurysm increased slightly after implantation of the stent in all five models. This result differs from that previously published, and may help guide the design and assist clinicians in selecting an appropriate stent for treating cerebral aneurysms. Copyright 2010 Elsevier Ltd. All rights reserved.

Entities:  

Mesh:

Year:  2010        PMID: 20227079     DOI: 10.1016/j.jbiomech.2010.01.009

Source DB:  PubMed          Journal:  J Biomech        ISSN: 0021-9290            Impact factor:   2.712


  12 in total

1.  Repression of wall shear stress inside cerebral aneurysm at bifurcation of anterior cerebral artery by stents.

Authors:  Ryuhei Yamaguchi; Gaku Tanaka; Hao Liu; Hiroshi Ujiie
Journal:  Heart Vessels       Date:  2015-03-27       Impact factor: 2.037

2.  The 'Sphere': A Dedicated Bifurcation Aneurysm Flow-Diverter Device.

Authors:  Thomas Peach; J Frederick Cornhill; Anh Nguyen; Howard Riina; Yiannis Ventikos
Journal:  Cardiovasc Eng Technol       Date:  2014-08-26       Impact factor: 2.495

3.  Influence of different computational approaches for stent deployment on cerebral aneurysm haemodynamics.

Authors:  Annarita Bernardini; Ignacio Larrabide; Hernán G Morales; Giancarlo Pennati; Lorenza Petrini; Salvatore Cito; Alejandro F Frangi
Journal:  Interface Focus       Date:  2011-03-23       Impact factor: 3.906

4.  Hemodynamic alterations after stent implantation in 15 cases of intracranial aneurysm.

Authors:  Chao Wang; Zhongbin Tian; Jian Liu; Linkai Jing; Nikhil Paliwal; Shengzhang Wang; Ying Zhang; Jianping Xiang; Adnan H Siddiqui; Hui Meng; Xinjian Yang
Journal:  Acta Neurochir (Wien)       Date:  2016-01-08       Impact factor: 2.216

5.  High fidelity virtual stenting (HiFiVS) for intracranial aneurysm flow diversion: in vitro and in silico.

Authors:  Ding Ma; Travis M Dumont; Hiroyuki Kosukegawa; Makoto Ohta; Xinjian Yang; Adnan H Siddiqui; Hui Meng
Journal:  Ann Biomed Eng       Date:  2013-04-20       Impact factor: 3.934

6.  Hemodynamic Changes Caused by Flow Diverters in Rabbit Aneurysm Models: Comparison of Virtual and Realistic FD Deployments Based on Micro-CT Reconstruction.

Authors:  Jinyu Xu; Benqiang Deng; Yibin Fang; Ying Yu; Jiyong Cheng; Shengzhang Wang; Kuizhong Wang; Jian-Min Liu; Qinghai Huang
Journal:  PLoS One       Date:  2013-06-18       Impact factor: 3.240

7.  Transient hemodynamic changes upon changing a BCPA into a TCPC in staged Fontan operation: a computational model study.

Authors:  Fuyou Liang; Hideaki Senzaki; Zhaofang Yin; Yuqi Fan; Koichi Sughimoto; Hao Liu
Journal:  ScientificWorldJournal       Date:  2013-11-10

8.  Simulation of contrast agent transport in arteries with multilayer arterial wall: impact of arterial transmural transport on the bolus delay and dispersion.

Authors:  Min Xu; Xiao Liu; Ang Li; Yubo Fan; Anqiang Sun; Xiaoyan Deng; Deyu Li
Journal:  ScientificWorldJournal       Date:  2014-11-17

9.  Fast Virtual Stenting with Active Contour Models in Intracranical Aneurysm.

Authors:  Jingru Zhong; Yunling Long; Huagang Yan; Qianqian Meng; Jing Zhao; Ying Zhang; Xinjian Yang; Haiyun Li
Journal:  Sci Rep       Date:  2016-02-15       Impact factor: 4.379

10.  The study of flow diversion effects on aneurysm using multiple enterprise stents and two flow diverters.

Authors:  Masahiro Kojima; Keiko Irie; Toshio Fukuda; Fumihito Arai; Yuichi Hirose; Makoto Negoro
Journal:  Asian J Neurosurg       Date:  2012-10
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.