Literature DB >> 20223099

Evaluation of the usefulness of an oxycodone immunoassay in combination with a traditional opiate immunoassay for the screening of opiates in urine.

Marie Gingras1, Marie-Hélène Laberge, Michel Lefebvre.   

Abstract

Oxycodone is a semisynthetic opioid analgesic largely prescribed for post-operative and chronic pain management. The introduction of a slow release formulation of oxycodone has led to its frequent abuse and to an increase in emergency cases related to oxycodone overdose. Until recently, oxycodone testing has been confined to gas chromatography-mass spectrometry (GC-MS) analysis because the widely used automated opiate immunoassays poorly react to this compound. We investigated the utility of a new oxycodone immunoassay as a screening procedure to eliminate inappropriate GC-MS testing of negative urine specimens. We analyzed 96 urine specimens using GC-MS and two immunoassays, CEDIA((R)) opiates and DRI((R)) oxycodone assays from Microgenics, on a Hitachi 917 analyzer. The GC-MS allowed us to detect codeine, hydrocodone, hydromorphone, morphine, oxycodone, and oxymorphone following enzymatic hydrolysis and derivation by acetylation. The combination of the two immunoassays gave the best performance (98% sensitivity and specificity) when considering a positive result from GC-MS for any of the opiates. Considering positive GC-MS results for oxycodone or oxymorphone only, the oxycodone immunoassay resulted in two false-positives and one false-negative (50 ng/mL cutoff). Using these immunoassays for screening before GC-MS analysis provides a reduced opiate GC-MS workload without compromising quality.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20223099     DOI: 10.1093/jat/34.2.78

Source DB:  PubMed          Journal:  J Anal Toxicol        ISSN: 0146-4760            Impact factor:   3.367


  5 in total

Review 1.  Laboratory testing for prescription opioids.

Authors:  Michael C Milone
Journal:  J Med Toxicol       Date:  2012-12

2.  Comparison of Response of DRI Oxycodone Semiquantitative Immunoassay With True Oxycodone Values Determined by Liquid Chromatography Combined With Tandem Mass Spectrometry: Sensitivity of the DRI Assay at 100 ng/ml Cut-Off and Validity of Semiquantitative Value.

Authors:  R Brent Dixon; Bonnette Davis; Amitava Dasgupta
Journal:  J Clin Lab Anal       Date:  2015-02-25       Impact factor: 2.352

3.  Opana ER (Oxymorphone)-Induced Thrombotic Microangiopathy: An Atypical Presentation in a Patient With Hepatitis C.

Authors:  Hassan Mehmood; Muzammil Khan; Asghar Marwat; Medha Joshi; Varun Malhotra
Journal:  J Investig Med High Impact Case Rep       Date:  2018-01-31

4.  Silver nanoparticle on zinc oxide array for label-free detection of opioids through surface-enhanced raman spectroscopy.

Authors:  Michael Zhang; Congran Jin; Yuan Nie; Yundong Ren; Nanjing Hao; Zhe Xu; Lin Dong; John X J Zhang
Journal:  RSC Adv       Date:  2021-03-17       Impact factor: 3.361

5.  A Difficult Challenge for the Clinical Laboratory: Accessing and Interpreting Manufacturer Cross-Reactivity Data for Immunoassays Used in Urine Drug Testing.

Authors:  Justine M Reschly-Krasowski; Matthew D Krasowski
Journal:  Acad Pathol       Date:  2018-11-21
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.