Literature DB >> 20219460

Regional variation in the biomechanical properties of the human sclera.

Ahmed Elsheikh1, Brendan Geraghty, Daad Alhasso, Jonathan Knappett, Marino Campanelli, Paolo Rama.   

Abstract

The study aimed to determine the variation in thickness and biomechanical properties between the different regions of the human sclera. Thickness measurements were carried out along eight meridian lines extending from the posterior pole to limbus in 36 human donor scleras aged 52-96 years. Strip specimens were extracted from areas close to the limbus, equator and posterior pole, and tested under cycles of uniaxial tension. Two strain rates were considered to assess the viscoelasticity effects on the regional variation in material behaviour. The results were used to derive the stress-strain behaviour of each specimen and to calculate the tangent modulus at each stress level. The scleras had a variable thickness from maximum at the posterior pole to minimum close to the equator, and increasing again towards the limbus. All scleral specimens demonstrated nonlinear behaviour with an initially low tangent modulus (a measure of stiffness) increasing gradually under higher stresses. With reference to specific stress levels, the behaviour comparisons between regions showed a gradual growth in material tangent stiffness with progression from the posterior region towards the limbus. The viscoelasticity of the tissue, which was evident with significant increases in stress (157-203%) and tangent modulus (30.3-38.8%) with strain rate rise (from 8% to 200% per min), was associated with reductions in the regional variation in stiffness. The considerable variation in biomechanical behaviour found in this study should be useful in improving the accuracy of representing the sclera's real-life conditions in numerical simulations. (c) 2010 Elsevier Ltd. All rights reserved.

Entities:  

Mesh:

Year:  2010        PMID: 20219460     DOI: 10.1016/j.exer.2010.02.010

Source DB:  PubMed          Journal:  Exp Eye Res        ISSN: 0014-4835            Impact factor:   3.467


  39 in total

1.  Biomechanical changes in the sclera of monkey eyes exposed to chronic IOP elevations.

Authors:  Michaël J A Girard; J-K Francis Suh; Michael Bottlang; Claude F Burgoyne; J Crawford Downs
Journal:  Invest Ophthalmol Vis Sci       Date:  2011-07-29       Impact factor: 4.799

2.  The optic nerve head as a robust biomechanical system.

Authors:  Ian A Sigal; Richard A Bilonick; Larry Kagemann; Gadi Wollstein; Hiroshi Ishikawa; Joel S Schuman; Jonathan L Grimm
Journal:  Invest Ophthalmol Vis Sci       Date:  2012-05-04       Impact factor: 4.799

3.  An applet to estimate the IOP-induced stress and strain within the optic nerve head.

Authors:  Ian A Sigal
Journal:  Invest Ophthalmol Vis Sci       Date:  2011-07-25       Impact factor: 4.799

4.  Microstructure-based numerical simulation of the mechanical behaviour of ocular tissue.

Authors:  Dong Zhou; Ahmed Abass; Ashkan Eliasy; Harald P Studer; Alexander Movchan; Natalia Movchan; Ahmed Elsheikh
Journal:  J R Soc Interface       Date:  2019-05-31       Impact factor: 4.118

5.  Location and pressure dependent transmission of human and porcine sclera: an anterior to posterior examination.

Authors:  Philipp Simon Koelbl; Pia Klante; Frank Koch; Christian Lingenfelder; Jens Ulrich Werner; Christian Enders; Martin Hessling
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2017-08-05       Impact factor: 3.117

6.  Ultrasonic measurement of scleral cross-sectional strains during elevations of intraocular pressure: method validation and initial results in posterior porcine sclera.

Authors:  Junhua Tang; Jun Liu
Journal:  J Biomech Eng       Date:  2012-09       Impact factor: 2.097

7.  A Novel Quantitative 500-MHz Acoustic Microscopy System for Ophthalmologic Tissues.

Authors:  Daniel Rohrbach; Anette Jakob; Harriet O Lloyd; Steffen H Tretbar; Ronald H Silverman; Jonathan Mamou
Journal:  IEEE Trans Biomed Eng       Date:  2016-05-26       Impact factor: 4.538

8.  Dynamic testing of regional viscoelastic behavior of canine sclera.

Authors:  Joel R Palko; Xueliang Pan; Jun Liu
Journal:  Exp Eye Res       Date:  2011-10-05       Impact factor: 3.467

9.  Finite Element Biomechanics of Optic Nerve Sheath Traction in Adduction.

Authors:  Andrew Shin; Lawrence Yoo; Joseph Park; Joseph L Demer
Journal:  J Biomech Eng       Date:  2017-10-01       Impact factor: 2.097

10.  Full-field displacement measurement of corneoscleral shells by combining multi-camera speckle interferometry with 3D shape reconstruction.

Authors:  Gianfranco Bianco; Luigi Bruno; Christopher A Girkin; Massimo A Fazio
Journal:  J Mech Behav Biomed Mater       Date:  2019-11-29
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.