Literature DB >> 20213452

Femoral neck resorption following hybrid metal-on-metal hip resurfacing arthroplasty: a radiological and biomechanical analysis.

Jibu Joseph1, Michael Mullen, Andrew McAuley, Anand Pillai.   

Abstract

INTRODUCTION: With the resurgence of resurfacing hip arthroplasty complications such as femoral neck fracture and thinning have been identified. We therefore conducted a radiological and biomechanical evaluation of factors affecting femoral neck resorption following resurfacing hip arthroplasty (RHA).
METHODS: We retrospectively reviewed 61 resurfacing hip arthroplasties in 53 patients with a minimum of a 2-year follow-up. Data regarding age, gender, body mass index, indication for surgery, and component size was obtained from case records. Radiographic measurements were made from standardised digital AP pelvic radiographs. The neck shaft angle, stem shaft angle, and the varus-valgus femoral stem alignment were calculated. Changes in abductor/body moment arm, hip ratio, and cup-to-neck ratio were calculated from the pre-op, immediate post-op and 2 year post-operative radiographs.
RESULTS: Femoral neck thinning was identified in 98% of cases (60/61) and was greater than 10% in 59% (39/61). The mean change in component-to-neck ratio was 0.12 (0-0.44). No significant relationship was found between the amount of femoral neck resorption and patient age, BMI, gender, diagnosis, component size or orientation. A significant positive correlation was found between a change in abductor moment arm and femoral neck resorption (R = 0.575; p < 0.01). We also calculated that approximately one-third of the change in CNR could be explained by a change in abductor moment arm. From this we formulated the Pillai-Joseph equation to calculate projected thinning at 2 years from the initial post-operative radiograph (CNR difference = 0.094 × AMA difference + 0.129).
CONCLUSIONS: RHA significantly alters hip biomechanics and this may result in altered loading patterns with adaptive remodelling causing neck thinning. In order to minimise neck thinning care must be taken not to increase the abductor moment arm.

Entities:  

Mesh:

Year:  2010        PMID: 20213452     DOI: 10.1007/s00402-010-1070-y

Source DB:  PubMed          Journal:  Arch Orthop Trauma Surg        ISSN: 0936-8051            Impact factor:   3.067


  4 in total

1.  High revision rate at 5 years after hip resurfacing with the Durom implant.

Authors:  Florian D Naal; Ronny Pilz; Urs Munzinger; Otmar Hersche; Michael Leunig
Journal:  Clin Orthop Relat Res       Date:  2011-01-29       Impact factor: 4.176

2.  Bone mineral density in the femoral neck increases after hip resurfacing: a cohort with five-year follow-up.

Authors:  Charles A Willis-Owen; Henry D Atkinson; Roger D Oakeshott
Journal:  Int Orthop       Date:  2010-08-22       Impact factor: 3.075

Review 3.  The role of ultrasound in the assessment of post-operative complications following hip arthroplasty.

Authors:  H Douis; D J Dunlop; A M Pearson; J N O'Hara; S L J James
Journal:  Skeletal Radiol       Date:  2012-03-17       Impact factor: 2.199

4.  Longitudinal evaluation of time related femoral neck narrowing after metal-on-metal hip resurfacing.

Authors:  Wenbao Wang; Jeffrey A Geller; Rohit Hasija; Jung Keun Choi; David A Patrick; William Macaulay
Journal:  World J Orthop       Date:  2013-04-18
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.