Literature DB >> 20211267

High field BOLD response to forepaw stimulation in the mouse.

Joanna M Adamczak1, Tracy D Farr, Jörg U Seehafer, Daniel Kalthoff, Mathias Hoehn.   

Abstract

We have established a robust protocol for longitudinal fMRI in mice at high field MRI using a medetomidine anesthesia. Electrical forepaw stimulation in anesthetized animals is widely used to produce BOLD contrast in the primary somatosensory cortex. To preserve neuronal activity, most fMRI experiments used alpha-chloralose to produce sedation, but severe side effects make this procedure unsuitable for survival experiments. As advantageous alternative, the alpha(2)-adrenergic receptor agonist medetomidine has been applied successfully to permit longitudinal fMRI studies in rats. With the advent of transgenic technology, mouse models have become increasingly attractive raising the demand for implementation of a suitable fMRI protocol for mice. Therefore, we investigated the use of medetomidine for repetitive fMRI experiments in C57BL/6 mice. We evaluated the optimal medetomidine dose for subcutaneous application. Somatosensory evoked potentials (SSEPs) in the contralateral somatosensory cortex were recorded to assess brain activity under medetominidine following forepaw stimulation. Repetitive administration of medetomidine, the requirement for longitudinal brain activation studies, was well tolerated. Using the forepaw stimulation paradigm, we observed BOLD contrast in the contralateral somatosensory cortex in approximately 50% of the performed scans using gradient echo-echo planar imaging (GE-EPI). However, imaging the small mouse brain at high field strength is challenging and we observed strong susceptibility artifacts in GE-EPI images in the cortex. We have developed an agar gel cap for successful compensation of these artifacts as prerequisite for successful mouse fMRI at 11.7T. The established protocol will be suitable for brain activation studies in transgenic animals and for studies of functional deficit and recovery after brain injury in mice. Copyright 2010 Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20211267     DOI: 10.1016/j.neuroimage.2010.02.083

Source DB:  PubMed          Journal:  Neuroimage        ISSN: 1053-8119            Impact factor:   6.556


  45 in total

Review 1.  Noise and non-neuronal contributions to the BOLD signal: applications to and insights from animal studies.

Authors:  Shella D Keilholz; Wen-Ju Pan; Jacob Billings; Maysam Nezafati; Sadia Shakil
Journal:  Neuroimage       Date:  2016-12-22       Impact factor: 6.556

2.  Role of Genetic Variation in Collateral Circulation in the Evolution of Acute Stroke: A Multimodal Magnetic Resonance Imaging Study.

Authors:  Yu-Chieh Jill Kao; Esteban A Oyarzabal; Hua Zhang; James E Faber; Yen-Yu Ian Shih
Journal:  Stroke       Date:  2017-02-10       Impact factor: 7.914

3.  Diffusion fMRI detects white-matter dysfunction in mice with acute optic neuritis.

Authors:  Tsen-Hsuan Lin; William M Spees; Chia-Wen Chiang; Kathryn Trinkaus; Anne H Cross; Sheng-Kwei Song
Journal:  Neurobiol Dis       Date:  2014-03-13       Impact factor: 5.996

Review 4.  Comprehensive neurocognitive endophenotyping strategies for mouse models of genetic disorders.

Authors:  Michael R Hunsaker
Journal:  Prog Neurobiol       Date:  2012-01-13       Impact factor: 11.685

5.  Functional MRI in mice lacking IP3-dependent calcium signaling in astrocytes.

Authors:  Pierrick Jego; Jesús Pacheco-Torres; Alfonso Araque; Santiago Canals
Journal:  J Cereb Blood Flow Metab       Date:  2014-08-06       Impact factor: 6.200

6.  Quantitative assessment of cerebral venous blood T2 in mouse at 11.7T: Implementation, optimization, and age effect.

Authors:  Zhiliang Wei; Jiadi Xu; Peiying Liu; Lin Chen; Wenbo Li; Peter van Zijl; Hanzhang Lu
Journal:  Magn Reson Med       Date:  2017-12-21       Impact factor: 4.668

7.  Optogenetic fMRI and electrophysiological identification of region-specific connectivity between the cerebellar cortex and forebrain.

Authors:  Katrina Y Choe; Carlos F Sanchez; Neil G Harris; Thomas S Otis; Paul J Mathews
Journal:  Neuroimage       Date:  2018-02-27       Impact factor: 6.556

8.  Fiber-optic implant for simultaneous fluorescence-based calcium recordings and BOLD fMRI in mice.

Authors:  Felix Schlegel; Yaroslav Sych; Aileen Schroeter; Jillian Stobart; Bruno Weber; Fritjof Helmchen; Markus Rudin
Journal:  Nat Protoc       Date:  2018-03-29       Impact factor: 13.491

9.  CNS animal fMRI in pain and analgesia.

Authors:  David Borsook; Lino Becerra
Journal:  Neurosci Biobehav Rev       Date:  2010-11-30       Impact factor: 8.989

10.  Structured illumination diffuse optical tomography for noninvasive functional neuroimaging in mice.

Authors:  Matthew D Reisman; Zachary E Markow; Adam Q Bauer; Joseph P Culver
Journal:  Neurophotonics       Date:  2017-04-13       Impact factor: 3.593

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.