Literature DB >> 20210478

Integration of single-fiber reflectance spectroscopy into ultrasound-guided endoscopic lung cancer staging of mediastinal lymph nodes.

Stephen Chad Kanick1, Cor van der Leest, Joachim G J V Aerts, Henk C Hoogsteden, Slávka Kascáková, Henricus J C M Sterenborg, Arjen Amelink.   

Abstract

We describe the incorporation of a single-fiber reflectance spectroscopy probe into the endoscopic ultrasound fine-needle aspiration (EUS-FNA) procedure utilized for lung cancer staging. A mathematical model is developed to extract information about the physiological and morphological properties of lymph tissue from single-fiber reflectance spectra, e.g., microvascular saturation, blood volume fraction, bilirubin concentration, average vessel diameter, and Mie slope. Model analysis of data from a clinical pilot study shows that the single-fiber reflectance measurement is capable of detecting differences in the physiology between normal and metastatic lymph nodes. Moreover, the clinical data show that probe manipulation within the lymph node can perturb the in vivo environment, a concern that must be carefully considered when developing a sampling strategy. The data show the feasibility of this novel technique; however, the potential clinical utility has yet to be determined.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20210478     DOI: 10.1117/1.3290822

Source DB:  PubMed          Journal:  J Biomed Opt        ISSN: 1083-3668            Impact factor:   3.170


  10 in total

1.  Development of a noncontact diffuse optical spectroscopy probe for measuring tissue optical properties.

Authors:  Sheldon F Bish; Narasimhan Rajaram; Brandon Nichols; James W Tunnell
Journal:  J Biomed Opt       Date:  2011-12       Impact factor: 3.170

Review 2.  Recent advances in optical coherence tomography for the diagnoses of lung disorders.

Authors:  Randy Hou; Tho Le; Septimiu D Murgu; Zhongping Chen; Matt Brenner
Journal:  Expert Rev Respir Med       Date:  2011-10       Impact factor: 3.772

3.  In-vivo monitoring of tissue oxygen saturation in deep brain structures using a single fiber optical system.

Authors:  Linhui Yu; Ying Wu; Jeff F Dunn; Kartikeya Murari
Journal:  Biomed Opt Express       Date:  2016-10-21       Impact factor: 3.732

4.  Characterizing human pancreatic cancer precursor using quantitative tissue optical spectroscopy.

Authors:  Seung Yup Lee; William R Lloyd; Malavika Chandra; Robert H Wilson; Barbara McKenna; Diane Simeone; James Scheiman; Mary-Ann Mycek
Journal:  Biomed Opt Express       Date:  2013-11-14       Impact factor: 3.732

5.  Optical pre-screening for laryngeal cancer using reflectance spectroscopy of the buccal mucosa.

Authors:  Oisín Bugter; Jose A Hardillo; Robert J Baatenburg de Jong; Arjen Amelink; Dominic J Robinson
Journal:  Biomed Opt Express       Date:  2018-09-06       Impact factor: 3.732

6.  In vivo optical spectroscopy for improved detection of pancreatic adenocarcinoma: a feasibility study.

Authors:  William R Lloyd; Robert H Wilson; Seung Yup Lee; Malavika Chandra; Barbara McKenna; Diane Simeone; James Scheiman; Mary-Ann Mycek
Journal:  Biomed Opt Express       Date:  2013-12-02       Impact factor: 3.732

7.  Effect of bile absorption coefficients on the estimation of liver tissue optical properties and related implications in discriminating healthy and tumorous samples.

Authors:  Rami Nachabé; Daniel J Evers; Benno H W Hendriks; Gerald W Lucassen; Marjolein van der Voort; Jelle Wesseling; Theo J M Ruers
Journal:  Biomed Opt Express       Date:  2011-02-15       Impact factor: 3.732

8.  Measurement of the reduced scattering coefficient of turbid media using single fiber reflectance spectroscopy: fiber diameter and phase function dependence.

Authors:  S C Kanick; U A Gamm; M Schouten; H J C M Sterenborg; D J Robinson; A Amelink
Journal:  Biomed Opt Express       Date:  2011-05-25       Impact factor: 3.732

9.  Correlating light scattering with internal cellular structures.

Authors:  Oana C Marina; Claire K Sanders; Judith R Mourant
Journal:  Biomed Opt Express       Date:  2012-01-13       Impact factor: 3.732

10.  Use of a coherent fiber bundle for multi-diameter single fiber reflectance spectroscopy.

Authors:  C L Hoy; U A Gamm; H J C M Sterenborg; D J Robinson; A Amelink
Journal:  Biomed Opt Express       Date:  2012-09-12       Impact factor: 3.732

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.