Literature DB >> 20209199

Systematic review of prosthetic maintenance requirements for implant-supported overdentures.

Murat Cavit Cehreli1, Durdu Karasoy, Ali Murat Kokat, Kiyanc Akca, Steven E Eckert.   

Abstract

PURPOSE: To evaluate prosthetic maintenance requirements for implant-retained/supported overdentures via a review of the literature.
MATERIALS AND METHODS: Using the combined search terms "implant and overdenture," "implant-supported overdenture," "implant-retained overdenture," and "implant-anchored overdenture," along with specific inclusion and exclusion criteria, eligible articles between 1997 and 2008 (up to April 1) were retrieved from PubMed, EMBASE, OVID, the Cochrane Library databases, and seven journals by hand-searching. The initial search yielded 3,120 titles, and 287 articles were assigned to full-text analysis. Upon classification of the prosthetic complications with regard to the jaws treated and the attachment systems used, within- and between-group comparative frequency analyses were undertaken with the Kruskal-Wallis test or the Mann-Whitney U test at P < .05.
RESULTS: A total of 49 articles were included. Within- and between-group evaluations with regard to jaw treated as well as the attachment systems used showed that the frequency of complications did not change over time (P > .05). The differences detected were more matrix replacements after 5 years in the maxilla and mandible and more matrix replacements and patrix fractures after the first year in the mandible (P < .05). Among the attachment systems, a dislodged, worn, or loose matrix or its respective housing was more common in the ball-attachment group after the first year (P < .05). Prosthetic complications for all types of attachments were comparable (P > .05), except for the differences in peri-implant or interabutment mucosal enlargement rates after 1 year.
CONCLUSIONS: Prosthetic maintenance requirements for overdentures on both jaws seem to be comparable. The impact of attachment system on the prosthetic outcome is negligible.

Entities:  

Mesh:

Year:  2010        PMID: 20209199

Source DB:  PubMed          Journal:  Int J Oral Maxillofac Implants        ISSN: 0882-2786            Impact factor:   2.804


  13 in total

1.  Stud attachments for the mandibular implant-retained overdentures: Prosthetic complications. A literature review.

Authors:  Elie E Daou
Journal:  Saudi Dent J       Date:  2013-02-06

2.  Patient satisfaction and survival of maxillary overdentures supported by four or six splinted implants: a systematic review with meta-analysis.

Authors:  Fabrizio Di Francesco; Emilio A Cafferata; Gennaro De Marco; Estefani B Capcha; Alessandro Lanza; Corina M Cristache; Rolando Vernal
Journal:  BMC Oral Health       Date:  2021-05-08       Impact factor: 2.757

3.  Biomechanical 3-dimensional finite element analysis of obturator protheses retained with zygomatic and dental implants in maxillary defects.

Authors:  Canan Akay; Suat Yaluğ
Journal:  Med Sci Monit       Date:  2015-02-25

Review 4.  Biomaterial aspects: A key factor in the longevity of implant overdenture attachment systems.

Authors:  Elie E Daou
Journal:  J Int Soc Prev Community Dent       Date:  2015 Jul-Aug

5.  Early Loaded Single Implant Reinforced Mandibular Overdenture.

Authors:  K Nischal; R Chowdhary
Journal:  Case Rep Dent       Date:  2016-06-14

6.  Current status of implant prosthetics in Japan: a survey among certified dental lab technicians.

Authors:  Yoshiyuki Hagiwara; Tatsuya Narita; Yohei Shioda; Keisuke Iwasaki; Takayuki Ikeda; Shunsuke Namaki; Thomas J Salinas
Journal:  Int J Implant Dent       Date:  2015-02-17

7.  Performance of attachments used in implant-supported overdentures: review of trends in the literature.

Authors:  Damian J Lee
Journal:  J Periodontal Implant Sci       Date:  2013-02-28       Impact factor: 2.614

8.  Interventions for replacing missing teeth: attachment systems for implant overdentures in edentulous jaws.

Authors:  Alan Gt Payne; Nabeel Hm Alsabeeha; Momen A Atieh; Marco Esposito; Sunyoung Ma; Marwah Anas El-Wegoud
Journal:  Cochrane Database Syst Rev       Date:  2018-10-11

9.  Clinical performance of LOCATOR® attachments: A retrospective study with 1-8 years of follow-up.

Authors:  Christophe Guédat; Ursina Nagy; Martin Schimmel; Frauke Müller; Murali Srinivasan
Journal:  Clin Exp Dent Res       Date:  2018-07-27

10.  Maxillary Implant-Supported Overdentures: Mechanical Behavior Comparing Individual Axial and Bar Retention Systems. A Cohort Study of Edentulous Patients.

Authors:  José Félix Mañes Ferrer; Lucía Fernández-Estevan; Eduardo Selva-Otaolaurruchi; Carlos Labaig-Rueda; María Fernanda Solá-Ruíz; Rubén Agustín-Panadero
Journal:  Medicina (Kaunas)       Date:  2020-03-19       Impact factor: 2.430

View more