Literature DB >> 20209185

Evaluation of accuracy of multiple dental implant impressions using various splinting materials.

Rasasubramanian Hariharan1, Chitra Shankar, Manoj Rajan, Mirza Rustum Baig, N S Azhagarasan.   

Abstract

PURPOSE: The aim of the present study was to compare the accuracy of casts obtained from nonsplinted and splinted direct impression techniques employing various splinting materials for multiple dental implants.
MATERIALS AND METHODS: A reference model with four Nobel Replace Select implant replicas in the anterior mandible was fabricated with denture base heat-curing acrylic resin. Impressions of the reference model were made using polyether impression material by direct nonsplinted and splinted techniques. Impressions were divided into four groups: group A: nonsplinted technique; group B: acrylic resin-splinted technique; group C: bite registration addition silicone-splinted technique; and group D: bite registration polyether-splinted technique. Four impressions were made for each group and casts were poured in type IV dental stone. Linear differences in interimplant distances in the x-, y-, and z-axes and differences in interimplant angulations in the z-axis were measured on the casts using a coordinate measuring machine.
RESULTS: The interimplant distance D1y showed significant variations in all four test groups (P = .043), while D3x values varied significantly between the acrylic resin-splinted and silicone-splinted groups. Casts obtained from the polyether-splinted group were the closest to the reference model in the x- and y-axes. In the z-axis, D2z values varied significantly among the three test groups (P = .009). Casts from the acrylic resin-splinted group were the closest to the reference model in the z-axis. Also, one of the three angles measured (angle 2) showed significant differences within three test groups (P = .009). Casts from the nonsplinted group exhibited the smallest angular differences.
CONCLUSION: Casts obtained from all four impression techniques exhibited differences from the reference model. Casts obtained using the bite registration polyether-splinted technique were the most accurate versus the reference model, followed by those obtained via the acrylic resin-splinted, nonsplinted, and bite registration addition silicone-splinted techniques.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 20209185

Source DB:  PubMed          Journal:  Int J Oral Maxillofac Implants        ISSN: 0882-2786            Impact factor:   2.804


  7 in total

Review 1.  Passive Fit in Screw Retained Multi-unit Implant Prosthesis Understanding and Achieving: A Review of the Literature.

Authors:  Muaiyed Mahmoud Buzayan; Norsiah Binti Yunus
Journal:  J Indian Prosthodont Soc       Date:  2013-12-28

2.  Evaluation of positional accuracy in multiple implants using four different splinting materials: An in vitro study.

Authors:  Thara Maria Joseph; R Ravichandran; S Lylajam; Prasanth Viswabharan; Kavitha Janardhanan; Smitha Rajeev
Journal:  J Indian Prosthodont Soc       Date:  2018 Jul-Sep

3.  Comparison of the accuracy of different impression procedures in case of multiple and angulated implants : Accuracy of impressions in multiple and angulated implants.

Authors:  M Wafa Richi; Sevcan Kurtulmus-Yilmaz; Oguz Ozan
Journal:  Head Face Med       Date:  2020-05-04       Impact factor: 2.151

4.  Effect of Different CAD/CAM Milling and 3D Printing Digital Fabrication Techniques on the Accuracy of PMMA Working Models and Vertical Marginal Fit of PMMA Provisional Dental Prosthesis: An In Vitro Study.

Authors:  Marina Sidhom; Hanaa Zaghloul; Ihab El-Sayed Mosleh; Elzahraa Eldwakhly
Journal:  Polymers (Basel)       Date:  2022-03-22       Impact factor: 4.329

5.  Comparison of implant cast accuracy of multiple implant impression technique with different splinting materials: An in vitro study.

Authors:  Sunantha Selvaraj; Jayachandran Dorairaj; Jayashree Mohan; Paul Simon
Journal:  J Indian Prosthodont Soc       Date:  2016 Apr-Jun

6.  Cast accuracy obtained from different impression techniques at different implant angulations (in vitro study).

Authors:  Enas A Elshenawy; Ahmed M Alam-Eldein; Fadel A Abd Elfatah
Journal:  Int J Implant Dent       Date:  2018-03-20

7.  Dimensional accuracy of vinyl polyether and polyvinyl siloxane impression materials in direct implant impression technique for multiple dental implants.

Authors:  Rohini Rajendran; N Gopi Chander; Kuttae Vishwanathan Anitha; Balasubramanian Muthukumar
Journal:  Eur Oral Res       Date:  2021-05-04
  7 in total