Literature DB >> 20206934

Filtering the surface EMG signal: Movement artifact and baseline noise contamination.

Carlo J De Luca1, L Donald Gilmore, Mikhail Kuznetsov, Serge H Roy.   

Abstract

The surface electromyographic (sEMG) signal that originates in the muscle is inevitably contaminated by various noise signals or artifacts that originate at the skin-electrode interface, in the electronics that amplifies the signals, and in external sources. Modern technology is substantially immune to some of these noises, but not to the baseline noise and the movement artifact noise. These noise sources have frequency spectra that contaminate the low-frequency part of the sEMG frequency spectrum. There are many factors which must be taken into consideration when determining the appropriate filter specifications to remove these artifacts; they include the muscle tested and type of contraction, the sensor configuration, and specific noise source. The band-pass determination is always a compromise between (a) reducing noise and artifact contamination, and (b) preserving the desired information from the sEMG signal. This study was designed to investigate the effects of mechanical perturbations and noise that are typically encountered during sEMG recordings in clinical and related applications. The analysis established the relationship between the attenuation rates of the movement artifact and the sEMG signal as a function of the filter band pass. When this relationship is combined with other considerations related to the informational content of the signal, the signal distortion of filters, and the kinds of artifacts evaluated in this study, a Butterworth filter with a corner frequency of 20 Hz and a slope of 12 dB/oct is recommended for general use. The results of this study are relevant to biomechanical and clinical applications where the measurements of body dynamics and kinematics may include artifact sources. Copyright 2010 Elsevier Ltd. All rights reserved.

Entities:  

Mesh:

Year:  2010        PMID: 20206934     DOI: 10.1016/j.jbiomech.2010.01.027

Source DB:  PubMed          Journal:  J Biomech        ISSN: 0021-9290            Impact factor:   2.712


  132 in total

1.  A method for detecting the temporal sequence of muscle activation during cycling using MRI.

Authors:  Christopher P Elder; Ryan N Cook; Kenneth L Wilkens; Marti A Chance; Otto A Sanchez; Bruce M Damon
Journal:  J Appl Physiol (1985)       Date:  2010-12-16

2.  Modeling nonlinear errors in surface electromyography due to baseline noise: a new methodology.

Authors:  Laura Frey Law; Chandramouli Krishnan; Keith Avin
Journal:  J Biomech       Date:  2010-09-25       Impact factor: 2.712

3.  Roller-massager application to the hamstrings increases sit-and-reach range of motion within five to ten seconds without performance impairments.

Authors:  Kathleen M Sullivan; Dustin B J Silvey; Duane C Button; David G Behm
Journal:  Int J Sports Phys Ther       Date:  2013-06

4.  Effect of unilateral knee extensor fatigue on force and balance of the contralateral limb.

Authors:  Shruti Arora; Shawn Budden; Jeannette M Byrne; David G Behm
Journal:  Eur J Appl Physiol       Date:  2015-06-06       Impact factor: 3.078

Review 5.  How to improve the muscle synergy analysis methodology?

Authors:  Nicolas A Turpin; Stéphane Uriac; Georges Dalleau
Journal:  Eur J Appl Physiol       Date:  2021-01-26       Impact factor: 3.078

6.  Muscle-tendon mechanics explain unexpected effects of exoskeleton assistance on metabolic rate during walking.

Authors:  Rachel W Jackson; Christopher L Dembia; Scott L Delp; Steven H Collins
Journal:  J Exp Biol       Date:  2017-03-24       Impact factor: 3.312

7.  Ranking hand movements for myoelectric pattern recognition considering forearm muscle structure.

Authors:  Youngjin Na; Sangjoon J Kim; Sungho Jo; Jung Kim
Journal:  Med Biol Eng Comput       Date:  2017-01-04       Impact factor: 2.602

8.  Location of Reference Electrode Does Not Interfere on Electromyographic Parameters in the Domains of Time and Frequency.

Authors:  Rinaldo Roberto de Jesus Guirro; Alcimar Barbosa Soares; Amanda Caldeira Guirro; Camila Simieli; Alessandra Vairo Peres Boratino; Gabriela de Carvalho; Aline Gobbi; Elaine Caldeira de Oliveira Guirro
Journal:  J Med Syst       Date:  2018-08-11       Impact factor: 4.460

9.  Effect of age on human-computer-interface control via neck electromyography.

Authors:  Gabrielle L Hands; Cara E Stepp
Journal:  Interact Comput       Date:  2014-08-10       Impact factor: 1.174

10.  Evaluating skeletal muscle electromechanical delay with intramuscular pressure.

Authors:  Shanette A Go; William J Litchy; Loribeth Q Evertz; Kenton R Kaufman
Journal:  J Biomech       Date:  2018-06-08       Impact factor: 2.712

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.