Literature DB >> 20206932

Valid micro finite element models of vertebral trabecular bone can be obtained using tissue properties measured with nanoindentation under wet conditions.

Uwe Wolfram1, Hans-Joachim Wilke, Philippe K Zysset.   

Abstract

Osteoporosis-related vertebral fractures represent a major public health problem. Anatomy-specific CT-based finite element (FE) simulations could help in identifying which vertebrae have the highest risk of fracture and thus help to decide upon the need for vertebroplasty or other surgical intervention. Continuum level FE simulations require effective macroscopic material properties of the vertebra. Micro finite element (microFE) models can be used to circumvent the difficult experiments that are necessary to determine these effective properties. From a quantitative point of view, these microFE models depend critically on the chosen trabecular tissue properties. The question remains whether linear elastic microFE models of vertebral trabecular bone with and without specimen-specific tissue properties yield similar results as non-destructive macroscopic experiments under moist conditions. microFE models were set up from microCT scans with specimen-specific or average tissue moduli measured by nanoindentation under dry and wet testing conditions. Non-destructive macroscopic mechanical compression, tension and torsion tests were performed. Experimentally obtained and simulated apparent stiffnesses were compared. No significant difference was found when comparing microFE simulations with wet tissue properties and experiments for tension, compression and torsion (p>0.05). Concordance correlation coefficients were high for tension and compression (r(c)(wet)>or=0.96,p<0.05) but moderate for torsion (r(c)(wet)=0.81,p<0.05). The agreement between simulation and experiment was confirmed by Bland-Altman plots which showed mean differences <or=10MPa. Surprisingly, the agreement between simulation and experiment was not reduced by using an average tissue modulus. The results indicate that valid microFE models can be set up using average tissue properties obtained under wet indentation conditions. Copyright (c) 2010 Elsevier Ltd. All rights reserved.

Entities:  

Mesh:

Year:  2010        PMID: 20206932     DOI: 10.1016/j.jbiomech.2010.02.026

Source DB:  PubMed          Journal:  J Biomech        ISSN: 0021-9290            Impact factor:   2.712


  22 in total

1.  Effect of specimen-specific anisotropic material properties in quantitative computed tomography-based finite element analysis of the vertebra.

Authors:  Ginu U Unnikrishnan; Glenn D Barest; David B Berry; Amira I Hussein; Elise F Morgan
Journal:  J Biomech Eng       Date:  2013-10-01       Impact factor: 2.097

2.  Predicting mouse vertebra strength with micro-computed tomography-derived finite element analysis.

Authors:  Jeffry S Nyman; Sasidhar Uppuganti; Alexander J Makowski; Barbara J Rowland; Alyssa R Merkel; Julie A Sterling; Todd L Bredbenner; Daniel S Perrien
Journal:  Bonekey Rep       Date:  2015-04-22

3.  Influence of the shape of the micro-finite element model on the mechanical properties calculated from micro-finite element analysis.

Authors:  Xin-Xin Wen; Hai-Long Yu; Ya-Bo Yan; Chun-Lin Zong; Hai-Jiao Ding; Xiang-Yu Ma; Tian-Sheng Wang; Wei Lei
Journal:  Exp Ther Med       Date:  2017-06-28       Impact factor: 2.447

4.  The effect of holding time on nanoindentation measurements of creep in bone.

Authors:  Ziheng Wu; Tyler A Baker; Timothy C Ovaert; Glen L Niebur
Journal:  J Biomech       Date:  2011-02-26       Impact factor: 2.712

5.  Rebound-associated vertebral fractures after discontinuation of denosumab-from clinic and biomechanics.

Authors:  A W Popp; P K Zysset; K Lippuner
Journal:  Osteoporos Int       Date:  2015-12-22       Impact factor: 4.507

6.  Variability of trabecular microstructure is age-, gender-, race- and anatomic site-dependent and affects stiffness and stress distribution properties of human vertebral cancellous bone.

Authors:  Yener N Yeni; Matthew J Zinno; Janardhan S Yerramshetty; Roger Zauel; David P Fyhrie
Journal:  Bone       Date:  2011-07-19       Impact factor: 4.398

7.  Fast trabecular bone strength predictions of HR-pQCT and individual trabeculae segmentation-based plate and rod finite element model discriminate postmenopausal vertebral fractures.

Authors:  X Sherry Liu; Ji Wang; Bin Zhou; Emily Stein; Xiutao Shi; Mark Adams; Elizabeth Shane; X Edward Guo
Journal:  J Bone Miner Res       Date:  2013-07       Impact factor: 6.741

8.  Finite element analysis for prediction of bone strength.

Authors:  Philippe K Zysset; Enrico Dall'ara; Peter Varga; Dieter H Pahr
Journal:  Bonekey Rep       Date:  2013-08-07

9.  Anterior and posterior variations in mechanical properties of human vertebrae measured by nanoindentation.

Authors:  Hugo Giambini; Hua-Jun Wang; Chunfeng Zhao; Qingshan Chen; Ahmad Nassr; Kai-Nan An
Journal:  J Biomech       Date:  2012-11-23       Impact factor: 2.712

10.  Non-invasive prediction of the mouse tibia mechanical properties from microCT images: comparison between different finite element models.

Authors:  S Oliviero; M Roberts; R Owen; G C Reilly; I Bellantuono; E Dall'Ara
Journal:  Biomech Model Mechanobiol       Date:  2021-02-01
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.