Comparison of real-time intraocular pressure during laser in situ keratomileusis and epithelial laser in situ keratomileusis in porcine eyes.

José L Hernández-Verdejo1, Laura de Benito-Llopis, Miguel A Teus.   

Abstract

PURPOSE: To compare real-time intraocular pressure (IOP) between laser in situ keratomileusis (LASIK) and epithelial LASIK (epi-LASIK) in porcine eyes during flap creation using a microkeratome or an epikeratome, respectively.
SETTING: Vissum Madrid, Madrid, Spain.
METHODS: In this prospective study, a Moria microkeratome was used in 1 eye (LASIK group) and an Epi-K epikeratome in the other eye (epi-LASIK group) to create a lamellar corneal flap and an epithelial flap, respectively, in freshly enucleated porcine eyes. The IOP changes during the procedures were recorded by direct cannulation using a reusable blood pressure transducer connected to the anterior chamber.
RESULTS: Each group comprised 17 eyes. In the LASIK group, the mean IOP was 113.65 mm Hg +/- 10.78 (SD) during suctioning and 112.35 +/- 11.51 mm Hg during cutting phases. The mean duration of the phases was 9.00 +/- 1.46 seconds and 6.06 +/- 1.14 seconds, respectively. In the epi-LASIK group, the mean IOP was 92.57 +/- 20.86 mm Hg during suctioning, 82.09 +/- 20 mm Hg during cutting, and 67.28 +/- 13.49 during low vacuum. The mean duration of the phases was 25.88 +/- 1.96 seconds, 33.82 +/- 2.81 seconds, and 29.71 +/- 3.29 seconds, respectively. The IOP values were significantly different between the 2 groups (all comparisons P<.05).
CONCLUSION: Real-time IOP measured during suctioning and flap creation by direct cannulation of the anterior chamber in freshly enucleated porcine eyes showed a significant increase in IOP during LASIK and epi-LASIK; the increase was lower in the epi-LASIK group. Copyright 2010 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2010        PMID: 20202548     DOI: 10.1016/j.jcrs.2009.09.040

Source DB:  PubMed          Journal:  J Cataract Refract Surg        ISSN: 0886-3350            Impact factor:   3.351


  5 in total

1.  Changes in corneal biomechanics and intraocular pressure following Femto-LASIK using Goldman applanation tonometry and ocular response analyzer.

Authors:  Ahmed Yassin Hemida; Omar M Said; Asser A E Abdel-Meguid; Mohammed Iqbal; Amani E Badawi
Journal:  Int J Ophthalmol       Date:  2020-05-18       Impact factor: 1.779

2.  Bilateral Iris Atrophy after the Femtosecond Assisted Laser In Situ Keratomileusis Surgery.

Authors:  Kenan Olcay; Akin Cakir; Sercan Koray Sagdic; Eyup Duzgun; Yildiray Yildirim
Journal:  Case Rep Ophthalmol Med       Date:  2015-06-14

Review 3.  The Effect of Corneal Refractive Surgery on Glaucoma.

Authors:  Vassilios Kozobolis; Aristeidis Konstantinidis; Haris Sideroudi; G Labiris
Journal:  J Ophthalmol       Date:  2017-04-09       Impact factor: 1.909

4.  Real-time measurement of intraocular pressure variation during automatic intravitreal injections: An ex-vivo experimental study using porcine eyes.

Authors:  Ikjong Park; Han Sang Park; Hong Kyun Kim; Wan Kyun Chung; Keehoon Kim
Journal:  PLoS One       Date:  2021-08-26       Impact factor: 3.240

5.  Microvascular changes in macula and optic nerve head after femtosecond laser-assisted LASIK: an optical coherence tomography angiography study.

Authors:  Yan Zhang; Jianqing Lan; Dan Cao; Cheng Yang; Dawei Yang; Wenjuan Xie; Jin Zeng
Journal:  BMC Ophthalmol       Date:  2020-03-17       Impact factor: 2.209

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.