Literature DB >> 20201116

Comparison of inter- and intraobserver agreement and reliability between three different types of placental volume measurement technique (XI VOCAL, VOCAL and multiplanar) and validity in the in-vitro setting.

K B Cheong1, K Y Leung, T K T Li, H Y Chan, Y P Lee, M H Y Tang.   

Abstract

OBJECTIVES: To compare XI VOCAL (eXtended Imaging Virtual Organ Computer-aided AnaLysis) for three-dimensional (3D) ultrasound volumetry of the placenta and of phantom objects with a rotational method using VOCAL and with the multiplanar method.
METHODS: We acquired 3D volume datasets from 32 fetuses at 11-14 weeks' gestation. Placental volume was calculated twice by each of two observers using XI VOCAL (with 5, 10, 15 and 20 slices), multiplanar (1-mm interval) and VOCAL (with 12 degrees, 18 degrees and 30 degrees rotation) methods. In addition, validity was assessed using the in-vitro setting with three phantom objects of known volume.
RESULTS: Both inter- and intraobserver reliabilities were very high for all three methods. There was no systematic bias between any two methods except between XI VOCAL (10 slices) and the multiplanar (1-mm interval) method, with a smaller volume using the former method. The limits of agreement were wide between any two of the three methods. In the in-vitro setting, there was a trend towards less valid measurements with the XI VOCAL technique and fewer slices. With the same number of steps, measurements made with VOCAL (12 degrees and 18 degrees) were more valid than were those made with XI VOCAL (15 and 10 slices, respectively).
CONCLUSION: XI VOCAL cannot be used interchangeably with VOCAL or multiplanar techniques in measuring placental volume at 11-14 weeks' gestation.

Mesh:

Year:  2010        PMID: 20201116     DOI: 10.1002/uog.7609

Source DB:  PubMed          Journal:  Ultrasound Obstet Gynecol        ISSN: 0960-7692            Impact factor:   7.299


  6 in total

1.  Intrastomal 3D ultrasound; an inter- and intra-observer evaluation.

Authors:  K Strigård; A Gurmu; P Näsvall; P Påhlman; U Gunnarsson
Journal:  Int J Colorectal Dis       Date:  2012-07-07       Impact factor: 2.571

2.  Segmentation of the placenta and its vascular tree in Doppler ultrasound for fetal surgery planning.

Authors:  Enric Perera-Bel; Mario Ceresa; Jordina Torrents-Barrena; Narcís Masoller; Brenda Valenzuela-Alcaraz; Eduard Gratacós; Elisenda Eixarch; Miguel A González Ballester
Journal:  Int J Comput Assist Radiol Surg       Date:  2020-09-19       Impact factor: 2.924

3.  A retrospective segmentation analysis of placental volume by magnetic resonance imaging from first trimester to term gestation.

Authors:  Rachel L León; Kevin T Li; Brandon P Brown
Journal:  Pediatr Radiol       Date:  2018-07-20

4.  Combining early (<11 weeks' gestation) ultrasound features and maternal factors to predict small-for-gestational age neonates.

Authors:  Tracey J Hanchard; Bradley S de Vries; Ann E Quinton; Michael Sinosich; Jonathan A Hyett
Journal:  Australas J Ultrasound Med       Date:  2020-08-20

5.  Effect of malaria on placental volume measured using three-dimensional ultrasound: a pilot study.

Authors:  Marcus J Rijken; William E Moroski; Suporn Kiricharoen; Noaeni Karunkonkowit; Gordon Stevenson; Eric O Ohuma; J Alison Noble; Stephen H Kennedy; Rose McGready; Aris T Papageorghiou; François H Nosten
Journal:  Malar J       Date:  2012-01-05       Impact factor: 2.979

6.  Reproducibility of 3-Dimensional Ultrasound Measurements of Placental Volume at Gestational Ages 11 - 14 Weeks.

Authors:  M L Larsen; K V Naver; M M Kjaer; F S Jorgensen; L Nilas
Journal:  Facts Views Vis Obgyn       Date:  2015-12-28
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.